• 제목/요약/키워드: Lift coefficient

검색결과 374건 처리시간 0.027초

서남권 도서지역에 적합한 1kW급 수평축 풍력터빈 로터 블레이드 설계 및 유동해석 (Design and Flow Analysis on the 1kW Class Horizontal Axis Wind Turbine Rotor Blade for Use in Southwest Islands Region)

  • 이준용;최낙준;윤한용;최영도
    • 한국유체기계학회 논문집
    • /
    • 제15권3호
    • /
    • pp.5-11
    • /
    • 2012
  • This study is to develop a 1kW-class horizontal axis wind turbine(HAWT) rotor blade which will be applicable to relatively low wind speed regions in southwest islands in Korea. Shape design of 1kW-class small wind turbine rotor blade is carried out using a blade profile with relatively high lift to drag ratio by blade element momentum theory(BEMT). Aerodynamic analysis on the newly designed rotor blade is performed with the variation of tip speed ratio. Power coefficient and pressure coefficient of the designed rotor blade are investigated according to tip speed ratio.

점용접부에서 하중속도효과를 고려한 피로수명평가 (Fatigue Life Evaluation of Spot Welding Including Loading Speed Effect)

  • 양성모;강희용;김홍진;송준혁
    • 한국공작기계학회논문집
    • /
    • 제12권1호
    • /
    • pp.32-37
    • /
    • 2003
  • Evaluation of fatigue strength on the spot welded part is very important for strength design of spot welded steel structures. In this paper, we could get the life cycle of the spot welded part using the lethargy coefficient obtained through the quasi-static tensile shear test for the specimen welded by current 10kA. The reliability evaluation of the life cycle is completed by comparing the life cycle calculated under the constant loading rate with the life cycle obtained by dynamic fatigue test. And then the result calculated by the lethargy coefficient is verified through the lift cycle calculated using the dynamic final tensile stress formula under the increased loading speed. This way can make save the time and cost in processing of predicting the life cycle of a structure.

정방형 실린더의 모서리 원형화에 따른 유동 불안정성의 변화 (EFFECTS OF ROUNDING CORNERS ON THE FLOW PAST A SQUARE CYLINDER)

  • 박두현;양경수;이경준;강창우
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.57-63
    • /
    • 2014
  • This study performed numerical analysis for the characteristics of flow-induced forces and the flow instability depending on the cross-sectional shape of the cylinder in laminar flow. To implement the cylinder cross-section, we adopted an Immersed Boundary Method with marker particles. We analyzed flow characteristics based on the radius of corner curvature. Main parameters are corner radius and Reynolds number (Re). With Re = 40, 50, 150 we calculated the flow field, drag coefficient, RMS of lift coefficient, pressure coefficient and Strouhal number in conjunction with the corner radius variation. Also, we calculated critical Reynolds number ($Re_c$) depending on the corner radius variation.

터보 차져 DI 디젤엔진에 있어서 성능 및 배기배출물에 미치는 흡기 포트 선회 유동 및 연료 분사계의 성능 (Effects of Intake Port Swirl and Fuel Injection System on the Performance and Exhaust Emissions in a Turbocharged DI Diesel Engine)

  • 윤준규;차경옥
    • 한국분무공학회지
    • /
    • 제10권3호
    • /
    • pp.45-53
    • /
    • 2005
  • The purpose of this study is to analyze that intake port swirl and fuel injection system have an effect on the engine performance in a turbocharged D.I. diesel engine of the displacement 9.4L. As result of steady flow test, when the valve eccentricity ratio moved to cylinder wall, the flow coefficient and swirl intensity is increased. And as the swirl is increased, the mean flow coefficient is decreased, whereas the Gulf factor is increased. Through this engine test, it can be expected to meet performance and emissions by the following applied parameters; the swirl ratio is 2.43, injection timing is BTDC 13oCA and compression is 15.5.

  • PDF

Euler 방정식을 사용한 익형 주위에서의 유동장 해석 (A Flowfield Analysis Around an Airfoil by Using the Euler Equations)

  • 김문상
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 춘계 학술대회논문집
    • /
    • pp.186-191
    • /
    • 1999
  • An Euler solver is developed to predict accurate aerodynamic data such as lift coefficient, drag coefficient, and moment coefficient. The conservation law form of the compressible Euler equations are used in the generalized curvilinear coordinates system. The Euler solver uses a finite volume method and the second order Roe's flux difference splitting scheme with min-mod flux limiter to calculate the fluxes accurately. An implicit scheme which includes the boundary conditions is implemented to accelerate the convergence rate. The multi-block grid is integrated into the flow solver for complex geometry. The flowfields are analyzed around NACA 0012 airfoil in the cases of $M_{\infty}=0.75,\;\alpha=2.0\;and\;M_{\infty}=0.80,\;\alpha=1.25$. The numerical results are compared with other numerical results from the literature. The final goal of this research is to prepare a robust and an efficient Navier-Stokes solver eventually.

  • PDF

Evaluation of the Aerodynamic Performance of A Hybrid Mesh Based Finite Volume Code

  • ZHENG, H.W.
    • International Journal of Aerospace System Engineering
    • /
    • 제2권2호
    • /
    • pp.40-43
    • /
    • 2015
  • A hybrid mesh based finite volume compressible flow code (PolySim) has been developed recently. Instead of the simple average method for the gradients of variables at each face, the volume average is applied for the calculation of the viscous flux. What is more, an improved Green Gauss method for the calculation of the gradient is also presented. These two techniques will improve both the accuracy and robustness of the code. The aerodynamic performance of this in-house cell centered code is examined by several widely-used bench-mark test cases. These cases include flows over flat plate and RAE 2822 etc. The comparisons on results between calculation and experiment are conducted. They show that the code can produce good numerical results which agree well with the corresponding experiment data.

Numerical simulation of flow around two circular cylinders in various arrangements

  • VU, HUY CONG;HWANG, JIN HWAN
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.334-334
    • /
    • 2015
  • The results of flow feature around two circular cylinders in various arrangements are carried out using two-dimensional simulation at Reynolds number of 200. In this work, time-averaged fluid force acting on the upstream and downstream cylinders were calculated for staggered angle ${\alpha}=0{\sim}90^{\circ}$ in the range of L/D = 1.1~5, where ${\alpha}$ is the angle between the free-stream flow and the line connecting the centers of the cylinders, L is centre-to-centre distance and D is cylinder diameter. The dependence of magnitudes and trends of fluid force coefficient on the spacing ratio L/D and ${\alpha}$ are discussed. In all arrangements of two cylinders, tandem arrangement (${\alpha}=0^{\circ}$) is the case produced a minimum drag coefficient for downstream cylinder. Moreover, the locations of separation and stagnation points or pressure coefficient on surface of the cylinder were examined. Acknowledgement: "This research was a part of the project titled 'Development of integrated estuarine management system', funded by the Ministry of Oceans and Fisheries, Korea."

  • PDF

아치형 2연동하우스의 풍력계수 분포에 관한 연구 (Distribution of Wind Force Coefficients on the Two-span Arched House)

  • 이석건;이현우
    • 생물환경조절학회지
    • /
    • 제1권2호
    • /
    • pp.142-147
    • /
    • 1992
  • The wind pressure distributions were analyzed to provide fundamental criteria for the structural design on the two-span arched house according to the wind directions through the wind tunnel experiment. In order to investigate the wind force distributions, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated using the experimental data. The results obtained are as follows : 1. The variation of the wind force with wind directions on the side walls was the greatest at the upwind edge of the walls. 2. The maximum negative wind force along the length of the roof appeared at the upwind edge at the wind direction of 60$^{\circ}$. 3. The maximum negative wind force along the width of the roof appeared at the width ratio and wind direction of 0$^{\circ}$ and 0.4 in the first house and 0.6 and 30$^{\circ}$ in the second house, respectively. 4. The mean negative wind force on the side walls of the first house at the wind direction of 0$^{\circ}$ was far greater than that of the second house, and the maximum negative wind force on the roof occurred at the wind direction of 30$^{\circ}$. 5. The maximum lift force appeared on the second house at the wind direction of 30$^{\circ}$, but the lift force on the first house was far greater than that on the second house at the wind direction of 0$^{\circ}$. 6. The parts to be considered for the local wind forces were the edges of the walls, and the edges of the x-direction and the width ratio, 0.4 of the y-direction in the roofs.

  • PDF

CFD를 이용한 범포 주위의 유동장 특성 (The characteristics of the flow field around canvas kite using the CFD)

  • 배봉성;배재현;안희춘;박성욱;박창두;정의철
    • 수산해양기술연구
    • /
    • 제42권3호
    • /
    • pp.169-178
    • /
    • 2006
  • This research aims at establishing the fundamental characteristics of the kite through the analysis of the flow field around various types of kites. The approach of this study were adopted for the analysis; visualization by CFD(computational fluid dynamics). Also, the lift/drag and PIV(particle image velocimetry) tests of kites had been performed in our previous finding. For this situation, models of canvas kite were designed by solidworks(design program) for the CFD test using the same conditions as in the lift/drag tests. And we utilized FloWorks as a CFD analysis program. The results obtained from the above approach are summarized as follows: According to comparison of the measured and analyzed results from mechanical tests, PIV and CFD test, the results of all test were similar. The numerical results of lift-coefficient and drag-coefficient were 5-20% less than those of the tests when attack angle is $10^{\circ},\;20^{\circ}\;and\;30^{\circ}$. In particular, it showed the 20% discrepancy at $40^{\circ}$. The numerical results of the ratio of drag and lift were 8-13% less than those of the tests at $10^{\circ}$ and 10% less than those of the tests at $20^{\circ},\;30^{\circ}\;and\;40^{\circ}$. Pressure distribution gradually became stable at $10^{\circ}$. In particular, the rectangular and triangular types had the centre of the high pressure field towards the leading edge and the inverted triangular type had it towards the trailing edge. The increase of the attack angle resulted in the eddy in order of the rectangular, triangular and inverted triangular type. The magnitude of the eddy followed the same order. The effect of edge-eddy was biggest in the triangular type followed by the rectangular and then the inverted triangular type. The action point of dynamic pressure as a function of the attack angle was close to the rear area of the model with the small attack angle, and with large attack angle, the action point was close to the front part of the model.

무인 해상 드론용 트윈 세일의 형태와 간격에 관한 연구 (Shape and Spacing Effects on Curvy Twin Sail for Autonomous Sailing Drone)

  • 팜민억;김부기;양창조
    • 해양환경안전학회지
    • /
    • 제26권7호
    • /
    • pp.931-941
    • /
    • 2020
  • 해양데이터를 수집하기 위해 필요한 엔지니어, 연구원 및 과학자를 대신할 수 있는 해양 모니터링 장치인 자율주행보트의 필요성이 대두되고 있다. 이 논문은 자율주행보트의 세일을 개발하기 위한 연구로 곡선형 트윈 세일의 공기역학적인 특성을 수치해석적으로 분석하고 이를 날개 형태의 세일과 성능비교를 통해 곡선형 트윈 세일의 공기 역학적인 성능을 확인하였고, 세일의 간격과 형상에 따른 성능을 비교하였다. 유체 해석을 위한 지배방정식은 Navier - Stokes를 사용하였다. 성능비교 결과 곡선 형 트윈 세일은 날개 형태의 세일과 비교하여 양력, 항력 및 추력 계수가 향상됨을 알 수 있다. 또한, 트윈 세일의 양 날개의 간격은 중요한 변수임을 확인 하였다. 0.035 L, 0.07 L, 0.14 L에서는 스톨로 인해 양력 계수의 감소로 나타났고 0.21 L, 0.28 L, 0.35 L에서는 개선되어 0.28 L에서 최대 양력을 보여준다.