• Title/Summary/Keyword: Life testing

Search Result 1,288, Processing Time 0.021 seconds

The best accelerated method and lifetime prediction of electrolytic capacitors (전해 캐패시터의 최적 가속시험방법과 수명예측)

  • Kim, Ha-Na;Sim, Chan-Ho;Kim, Sung-Jun;Yoon, Jung-Rag;Lee, Hun-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1945-1947
    • /
    • 2005
  • This study considers find out best accelerated life testing and lifetime prediction of electrolytic capacitors. We proved about relation between failure and deterioration mechanism from last thesis. Beside we performed test that temperature and voltage press higher than allowance specification. Failure distribution acquired from those test. And wiebull function and Minitab program applied to accelerated constant and lifetime by means of calculation. At the result, goodness of fit affect to weibull function and acceleration factor therefore fitting is important factor in reliability testing.

  • PDF

Thermal Fatigue and Wear Properties of High Speed Steel Roll for Hot Strip Mill (열간압연용 고속도공구강롤의 열피로 및 마모특성)

  • 류재화;박종일
    • Transactions of Materials Processing
    • /
    • v.6 no.2
    • /
    • pp.95-101
    • /
    • 1997
  • The thermal fatigue and wear properties of high speed steel roll which was recently developed were investigated by observing microstructure, by measuring mechanical and physical properties, by conducting thermal fatigue testing, and by measuring the amount of wear in actual mill. High speed steel roll had better thermal fatigue testing, and by measuring the amount of wear in actual mill. High speed steel roll had better thermal fatigue life than high chromium iron roll, which was due to lower carbide content, higher strength, and higher thermal conductivity. The amount of wear of high speed steel roll was nearly the same as that of high chromium iron roll in the first finishing stand, which was due to the oxide formation on the roll surface. However, in the third finishing stand, the wear resistance of high speed steel roll was 2~3 times as good as that of high chromium iron roll because the former had higher hardness at high temperature.

  • PDF

A Goodness of Fit Approach to Major Lifetesting Problems

  • Ahmad, Ibrahim A.;Alwasel, Ibrahim A.;Mugdadi, A.R.
    • International Journal of Reliability and Applications
    • /
    • v.2 no.2
    • /
    • pp.81-97
    • /
    • 2001
  • Lifetesting problems have been the subject of investigations for over three decades. Most suggested approaches are markedly different from those used in the related but wider goodness of fit problems. In the current investigation, it is demonstrated that a goodness of fit approach is possible in many lifetesting problems and that It results in simpler procedures that are asymptotically equivalent or better than standard ones. They may also have superior finite sample behavior. Several perennial classes are addressed here. The class of increasing failure rate (IFR) and the class of new better than used (NBU) are addressed first. In addition, we provide testing for a newer and practical class of new better than used in convex ordering (NBUC) due to Cao and Wang (1991). Other classes can be developed similarly and this point is illustrated with the classes of new better than used in expectation (NBUE) and harmonic new better than used in expectation (HNBUE).

  • PDF

Performance Evaluation of Elderly Home Automation Control (EHAC) IoT System

  • Phua, Karsten Cheng Kai;Goh, Wei Wei;Marjani, Mohsen
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.1
    • /
    • pp.214-219
    • /
    • 2021
  • As the number of elderly increased rapidly every year, many elderly still choose to stay independent despite of difficulties and challenges faced in their daily routine. Elderly has desperate needs for support for their living. Internet of Things helps to support and improve elderly's life in many ways to meet the needs and requirements. Home Automation Control (EHAC) is a research based system that support elderly with controlled automation solution that control and operates various home electrical appliances based on the measurement of heart pulse rate and environment temperature. This paper works on EHAC system to evaluate the performance of the system in elderly's daily routine. This paper presented experiments conducted with approach of IoT testing and discussion on analysis of the results.

Creep Damage Evaluation of Cr-Mo Steel High-Temperature Pipeline Material for Fossil Power Plant Using Ultrasonic Test Method (초음파법을 이용한 Cr-Mo강 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.18-26
    • /
    • 2000
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operating conditions such as high temperature and high pressure for an extended period time. Conventional measurement techniques(replica method, electric resistance method, and hardness test method) for measuring creep damage have such disadvantages as complex preparation and measurement procedures, too many control parameters. And also these techniques have low practicality and applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens(Cr-Mo alloy steels) were carried out for the purpose of evaluation for creep damage. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradation tests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens. we conformed that both the sound velocity decreased and attenuation coefficient linearly increased in proportion to the Increase of creep life fraction($\Phi$c).

  • PDF

Development of Calibration Target for Infrared Thermal Imaging Camera (적외선 열화상 카메라용 캘리브레이션 타겟 개발)

  • Kim, Su Un;Choi, Man Yong;Park, Jeong Hak;Shin, Kwang Yong;Lee, Eui Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.248-253
    • /
    • 2014
  • Camera calibration is an indispensable process for improving measurement accuracy in industry fields such as machine vision. However, existing calibration cannot be applied to the calibration of mid-wave and long-wave infrared cameras. Recently, with the growing use of infrared thermal cameras that can measure defects from thermal properties, development of an applicable calibration target has become necessary. Thus, based on heat conduction analysis using finite element analysis, we developed a calibration target that can be used with both existing visible cameras and infrared thermal cameras, by implementing optimal design conditions, with consideration of factors such as thermal conductivity and emissivity, colors and materials. We performed comparative experiments on calibration target images from infrared thermal cameras and visible cameras. The results demonstrated the effectiveness of the proposed calibration target.

Correlation of Occupational Stress Index with 24-hour Urine Cortisol and Serum DHEA Sulfate among City Bus Drivers: A Cross-sectional Study

  • Du, Chung-Li;Lin, Mia Chihya;Lu, Luo;Tai, John Jen
    • Safety and Health at Work
    • /
    • v.2 no.2
    • /
    • pp.169-175
    • /
    • 2011
  • Objectives: The questionnaire of occupational stress index (OSI) has been popular in the workplace, and it has been tailored for bus drivers in Taiwan. Nevertheless, its outcomes for participants are based on self-evaluations, thus validation by their physiological stress biomarker is warranted and this is the main goal of this study. Methods: A cross-sectional study of sixty-three city bus drivers and fifty-four supporting staffs for comparison was conducted. Questionnaire surveys, 24-hour urine cortisol testing, and blood draws for dehydroepiandrosterone-sulfate (DHEA-S) testing were performed. The measured concentrations of these biological measures were logarithmically transformed before the statistical analysis where various scores of stressor factors, moderators, and stress effects of each OSI domain were analyzed by applying multiple linear regression models. Results: For drivers, the elevated 24-hour urine cortisol level was associated with a worker's relationship with their supervisor and any life change events in the most recent 3 months. The DHEA-S level was higher in drivers of younger age as well as drivers with more concerns relating to their salary and bonuses. Non-drivers showed no association between any stressor or satisfaction and urine cortisol and blood DHEA-S levels. Conclusion: Measurements of biomarkers may offer additional stress evaluations with OSI questionnaires for bus drivers. Increased DHEA-S and cortisol levels may result from stressors like income security. Prevention efforts towards occupational stress and life events and health promotional efforts for aged driver were important anti-stress remedies.

A Study on the Reliability Analysis for Smoke Detector using Dust (분진을 이용한 연기감지기 신뢰성 분석에 관한 연구)

  • Hong, Sung Ho;Choi, Moon Soo;Lee, Young Man
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.6
    • /
    • pp.11-16
    • /
    • 2013
  • This paper presents a study on the analyzing reliability of smoke fire detector using accelerated life test. In general, the smoke fire detector is broken by dust which flow in smoke detection chamber. In order to conduct accelerated life test of smoke fire detector dust is set accelerated factor in this paper. The dust is fly-ash which is test particle 5th regulated by KS A 0090. The dust accelerated level is 60 g, 180 g and 360 g and failure time is measured by smoke sensitivity testing. It is considered to failure of detector if detector don't operate within 30 secconds when subjected to an air stream having a velocity of 20 cm/s~40 cm/s containing smoke with a concentration of 15% of rate of light-response of 1 m. The goodness of fit test and mean life prediction conduct using the failure time. The result show that life distribution fits the weibull distribution for failure time data and the mean lifes calculate 22.5 year in domestic product and 14.7 years in overseas product applied dust stress only.

An Accelerated Degradation Test of Electric Double-Layer Capacitors (전기이중층커패시터의 가속열화시험)

  • Jung, Jae-Han;Kim, Myung-Soo
    • Journal of Applied Reliability
    • /
    • v.12 no.2
    • /
    • pp.67-78
    • /
    • 2012
  • An electric double-layer capacitor(EDLC) is an electrochemical capacitor with relatively high energy density, typically hundreds of times greater than conventional electrolytic capacitors. EDLCs are widely used for energy storage rather than as general-purpose circuit components. They have a variety of commercial applications, notably in energy smoothing and momentary-load devices, and energy-storage and kinetic energy recovery system devices used in vehicles, etc. This paper presents an accelerated degradation test of an EDLC with rated voltage 2.7V, capacitance 100F, and usage temperature $-40^{\circ}C{\sim}65^{\circ}C$. The EDLCs are tested at $50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$, respectively for 1,750hours, and their capacitances are measured at predetermined times by constant current discharge method. The failure times are predicted from their capacitance deterioration patterns, where the failure is defined as 30% capacitance decrease from the initial one. It is assumed that the lifetime distribution of EDLC follows Weibull and Arrhenius life-stress relationship holds. The life-stress relationship, acceleration factor, and $B_{10}$ life at design condition are estimated by analyzing the accelerated life test data.

Optimum time-censored ramp soak-stress ALT plan for the Burr type XII distribution

  • Srivastava, P.W.;Gupta, T.
    • International Journal of Reliability and Applications
    • /
    • v.15 no.2
    • /
    • pp.125-150
    • /
    • 2014
  • Accelerated life tests (ALTs) are extensively used to determine the reliability of a product in a short period of time. Test units are subject to elevated stresses which yield quick failures. ALT can be carried out using constant-stress, step-stress, progressive-stress, cyclic-stress or random-stress loading and their various combinations. An ALT with linearly increasing stress is ramp-stress test. Much of the previous work on planning ALTs has focused on constant-stress, step-stress, ramp-stress schemes and their various combinations where the stress is generally increased. This paper presents an optimal design of ramp soak-stress ALT model which is based on the principle of Thermal cycling. Thermal cycling involves applying high and low temperatures repeatedly over time. The optimal plan consists in finding out relevant experimental variables, namely, stress rates and stress rate change points, by minimizing variance of reliability function with pre-specified mission time under normal operating conditions. The Burr type XII life distribution and time-censored data have been used for the purpose. Burr type XII life distribution has been found appropriate for accelerated life testing experiments. The method developed has been explained using a numerical example and sensitivity analysis carried out.

  • PDF