• 제목/요약/키워드: Liechtenstein

검색결과 70건 처리시간 0.029초

직접법과 간접법으로 수복한 복합레진의 1년간의 임상적인 평가 (1 YEAR FOLLOW-UP STUDY OF DIRECT AND INDIRECT COMPOSITE RESTORATIONS)

  • 박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.284-289
    • /
    • 2002
  • Background : The purpose of the present study was to evaluate the direct and indirect composite restorations which had been placed for 1 year Methods : The composite restorations which had been placed between 1999. Mar and 1999, Dec was evaluated after 1 year For direct restorations. Spectrum (Dentsply, USA) and Z100 (3M, USA) were used in the anterior teeth and Surefil (Dentsply, USA) were used. For class V restorations of anterior and posterior teeth. Spectrum was used. For indirect restorations, Targis/Vectris system (Vivadent/Ivoclar, Liechtenstein) was used 2 examiners evaluated marginal quality, proximal contact. discoloration, presence of 2$^{nd}$ caries, loss of filling and hypersensitivity of restorations. The restorations was clinically evaluated by modified methods based on USPHS. Results : 60 teeth were evaluated. 59 were clinically acceptable and 1 restoration which was placed in class v cavity in the posterior tooth was fallen out. In most cases, the restorations were clinically accept-able. For restorations which had been directly placed in the class II cavities, loose proximal contact was indicated as the main complaints. Conclusions : Most of Anterior and posterior restorations which bad been directly or indirectly placed for 1 year were clinically acceptable. For posterior teeth, loose proximal contact was indicated as the main problem in the directly placed Class II restorations. Long term clinical study is needed.

지르코니아 전장 세라믹의 파절강도에 관한 비교 연구 (Comparative Study in Fracture Strength of Zirconia Veneering Ceramics)

  • 이정환;안재석
    • 치위생과학회지
    • /
    • 제10권5호
    • /
    • pp.335-340
    • /
    • 2010
  • This study was performed to evaluate the fracture strength of the dental zirconia veneering ceramics for zirconia ceramic core. Six commercial zirconia veneering ceramics were used in this study, namely E-Max(Ivoclar vivadent, Inc, Liechtenstein), Creation ZI(KLEMA Dental produckte GmbH, Austria), Cercon ceram kiss(Degudent, GmbH, Hanau-Wolfgang, Germany), Triceram(Dentaurum, Ispringen, Germany), Zirkonzahn(Zirkonzahn GmbH, Italy), Zirmax(Alpadent, korea). All samples were prepared according to the relevant instructions of manufacture. Disc specimens were prepared to the final dimensions of 17 mm in diameter and 1.5 mm in thickness. The biaxial flexure strength test was conducted using a ball-on-three-ball method. All specimens were tested in a moisture-free environment. Average flexural strengths were analyzed with Weibull analysis and one-way analysis of variance(ANOVA). Significant differences were founded between the mean flexural strength values of five commercials zirconia veneering ceramics and the other. The flexural strengths and Weibull modulus were similar to those of five groups E-Max(EM), Creation ZI(CR), Cercon ceram kiss(CE), Triceram(TR), Zirkonzahn(ZI) with the exception of Zirmax(ZM). The biaxial flexural strength from Cercon ceram kiss(CE) was higher than those of other groups. Fracture analysis showed similar results for these five groups.

대구경북 치과위생사들의 치과재료에 대한 유해정보 소통 실태 (Hazard Communication of Dental Materials for Dental Hygienists in Daegu or Gyeongsangbuk-do Province Area)

  • 김해경;최상준
    • 한국산업보건학회지
    • /
    • 제25권4호
    • /
    • pp.506-515
    • /
    • 2015
  • Objectives: This study was conducted to evaluate the status of hazard communication regarding dental materials among dental hygienists in the Daegu Metropolitan City and the North Gyeongsang-do Province area. Materials: A total of 310 dental hygienists were surveyed using self-administered questionnaires to investigate the status of hazard communication on dental materials and information needs. We collected instructions for use and material safety data sheets(MSDSs) for 67 dental materials frequently used at dental hospitals located in the Daegu Metropolitan City and the North Gyeongsang-do Province area. Results: The questionnaire surveys showed that only 11% of the 310 dental hygienists had knowledge of MSDS and 46.8% of respondents never read instructions for use before using materials. Just 7.4% of dental hygienists have undergone training on hazard information for dental materials. In particular, dental hygienists working at dental clinics had significantly lower response rates on knowledge of MSDS(p<0.001), reading of instructions for use(p=0.042) and training on the hazard information of dental materials(p=0.004) than those in dental hospitals or general hospitals. The essential information most desired by dental hygienists was hazard identification(82.3%) followed by first-aid measures(53.9%), handling and storage(51%), disposal considerations (49%) and toxicological information(47.1%). All dental materials were on foreign products which came from Japan(59.7%), the USA(26.9%) and Liechtenstein(13.7%). In terms of usage, 56.7% of dental materials were prosthetic, followed by conservation(31.3%), orthodontics(9%), and prevention(3%). We found that dental hygienists had accessed MSDSs for only five dental products among the 67 dental materials. The instructions for the use of the 67 dental materials provided hazard identification(64.2%), first-aid measures(83.6%), handling and storage(97%), disposal considerations(20.9%) and toxicological information(26.9%). Conclusions: Based on the results of this study, the hazard communication system for dental hygienists working at dental clinics should be improved.

도재 수리용 레진의 색안정성에 관한 연구 (A STUDY ON THE COLOR STABILITY OF PORCELAIN REPAIR RESINS)

  • 김난영;진태호
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.133-141
    • /
    • 2004
  • Statement of problem : Porcelain restorations are widely used in restorative dentistry with a high degree of general success. However, porcelain is brittle and may fracture intraorally. Sometimes a repair may be attempted using composite resin and bonding system available. Color stability of porcelain repair resins affects esthetics and prognosis of prosthesis, so that provides important criteria for the choice of porcelain repair resins. Purpose : The purpose of this study was to investigate the color stability of composite resins used widely as porcelain repair system. Materials and method : Composite resins used for this study were Carisma(Kulzer, Germany), Tetric ceram(Ivoclar, Liechtenstein), Filtek Z250(3M, USA), and Arabesk Top(VOCO, Germany). Thirty disc-shaped specimens($10{\times}2mm$) were fabricated from each composite resin. Color changes of specimens after treatment using thermocycling system(KD-TCS30, Kwang-duk F.A. Korea) and after immersion in methylene blue(0.05% by Wt) were measured with colorimeter(Model Tc-6Fx, Tokyo Denshoku Co.) and obtained data were analyzed. Results and Conclusion: The results obtained from this study were as fo11ows. 1. The color change of Filtek Z250 was lesser than those of Tetric ceram and Arabesk Top after thermocycling (12000 times). 2. All of the composite resins in this study showed increase of color change according to increase of thermocycling frequency. 3. After treatment with methylene blue, the color change of Arabesk Top was greater than those of Carisma and Tetric ceram, and Tetric ceram was more stable than others.

상아질 지각완화제가 레진시멘트의 전단결합강도에 미치는 영향 (EFFECT OF DENTIN DESENSITIZERS ON SHEAR BOND STRENGTH OF RESIN CEMENTS)

  • 이호;진태호;손외수;안희영
    • 대한치과보철학회지
    • /
    • 제40권4호
    • /
    • pp.365-373
    • /
    • 2002
  • The purpose of this study was to investigate the effects of desensitizer on shear bond strength of adhesive resin cements for all ceramic crown. For this study, Gluma $desensitizer^{(R)}$(Heraeus Kulzer, Germany) and MS $Coat^{(R)}$(Sun medical, Japan) were used as desensitizer, and Bistite $II^{(R)}$ resin cement(Tokuyama, Japan) and Variolink $II^{(R)}$ resin cement (Ivoclar, Liechtenstein) were used. IPS Empress ceramics were bonded to dentin surfaces after application of desensitizer and shear bond strength of specimens were measured using UTM(Zwick 1456 41. Zwick, Germany) at a crosshead speed of 1mm/min. The obtained results were as follows : 1. The shear bond strength of both resin cements were not affected by Gluma $desensitizer^{(R)}$ containing HEMA 2. The shear bond strength of Bistite $II^{(R)}$ resin cement was significantly decreased by MS $Coat^{(R)}$. 3. The failure mode in MS $Coat^{(R)}-Bistite \;II^{(R)}$ group was mainly adhesive type between dentin and resin cement. but that of Gluma $desensitizer^{(R)}$-Variolink $II^{(R)}$ group was mainly mixed type, combined adhesive failures between dentin and resin cement or porcelain and resin cement.

포스트 접착 시멘트의 종류와 적용 방법에 따른 접착 효율 비교 (Comparison of the post cementation efficacy using different cements and methods)

  • 조옥인;이상진;박정길;허복;김현철
    • 대한치과의사협회지
    • /
    • 제48권9호
    • /
    • pp.680-687
    • /
    • 2010
  • The purpose of this study was to compare post cementation efficacy according to the different adhesive systems and cement delivery methods. A total of 40 extracted human single-rooted premolar teeth were randomly divided in four groups according to the two luting agents of Unicem applicap (3M ESPE, St. Paul, MN, USA) or Variolink II (Ivoclar Vivadent, Liechtenstein) and cement delivery methods of direct cement application or lentulo spiral application. After restoration using glass?fiber posts, the samples were embedded in acrylic resin. Three sections of 2 mm thickness were prepared from each specimen, and the post in each section was subjected to a push-out test. The data were analysed statistically at significant level of 95%. The Unicem had significantly higher push-out bond strength than Variolink and the lentulo spiral application made higher bond strength (p<0.05). Adhesive failure between cement and dentin was predominant in all groups. The Unicem of self-etch system and cement delivery using lentulo spiral showed clinically acceptable and comparable bonding strength for the fiber post.

열가압 방식의 금속-유리도재 이중 구조물의 전단결합강도에 대한 연구 (Shear bond strength in bilayer metal-heat pressed glass ceramic structure)

  • 이경은;박진영;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제39권2호
    • /
    • pp.101-107
    • /
    • 2017
  • Purpose: The purpose of this study was to compare the shear bond strength of the metal-heat pressed glass ceramic bilayer structure. Methods: Metal framework specimens were prepared and surface is spreaded opaque(IPS InLine system opaque, IvoclarVivadent, Liechtenstein). There were 10 specimens for each bilayer dental ceramic group. The first group was porcelain fused metal, Press on metal IPS Inline press group, and press on metal HASS prototype group. Specimens measured for the shear bond strength on Schwickerath test by Instron universal testing machine(Instron3345, Instron Corp., USA). Mean average bond strength values of each specimen group were analyzed using a one-way ANOVA analysis of variance Saphiro-wilk's test. Statistical analysis were performed using IBM SPSS 23.0(IBM Co., Armonk, USA) Results: $RMS{\pm}SD$ The highest mean average HASS POM showed a bond strength value ($47.55{\pm}12.80Mpa$). The lowest mean average values Porcelain fused metal ($33.30{\pm}2.00Mpa$). Independent t-test was conduct to analysis the significant difference (p<0.05) (Table 3). Conclusion: Three kinds of Metal/ glass bilayer dental ceramics bond strength were clinical acceptability. Especially, as lithium disilicate containing represents higher bond strength.

열순환이 상아질접착제 처리 후 미세누출에 미치는 영향에 관한 연구 (The Study of the Effect of Thermocycling on Microleakage within Various Dentin Bonding Agents)

  • 유승훈
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.147-155
    • /
    • 2008
  • 5세대 상아질 접착제인 Adper Single bond 2.0 (3M-ESPE, USA), 6세대 상아질 접착제인 Prompt L-pop (3M-ESPE, USA), AdheSE (Ivoclar Vivadent, Liechtenstein) 를 각 상아질 접착제당 30개의 건전한 소구치 및 대구치를 선정하여 협면과 설면에 5급와동을 형성하고 복합레진을 적용하였다. 이중 절반은 열순환을 시행하지 않고 나머지 절반은 열순환을 시행하였다. 이후 메틸렌 블루를 침투시켜 시약의 침투 정도를 측정한 후 통계분석하였다. 열순환을 시행하지 않은 군과 열순환을 시행한 군을 통틀어 열순환을 시행하지 않은 상아질 군에서만 Single Bond 2.0의 미세누출의 양이 Prompt L-Pop과 AdheSE에 비하여 높았고 (p <.05) 나머지 군에서는 모두 Single Bond 2.0의 미세누출의 양이 적었다. (p <.05) 열순환 이후에 미세누출의 양이 늘어난 군은 Prompt L-Pop과 AdheSE의 상아질 군이었다.

The effect of powder A2/powder A3 mixing ratio on color and translucency parameters of dental porcelain

  • Lee, Wan-Sun;Kim, So-Yeon;Kim, Ji-Hwan;Kim, Woong-Chul;Kim, Hae-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.400-405
    • /
    • 2015
  • PURPOSE. The purpose of this study is to mix dental ceramic powder in varying ratios and evaluate the effect of the mixing ratio on color and translucency. MATERIALS AND METHODS. The ceramic powder of shade A3 of the same product was mixed with the shade A2 of three products: IPS e.max Ceram (Ivoclar Vivadent, Schaan, Liechtenstein), Vintage Halo (SHOFU Inc., Kyoto, Japan), and Ceramco 3 (Ceramco-Dentsply, Burlington, NJ, USA) in the following fixed ratios (0 wt%, 25 wt%, 50 wt%, 75 wt%, and 100 wt%) and then fired. A total of 150 specimen of ceramic fired were manufactured in a regular size (W: 8.5 mm, L: 10.5 mm, and H: 1.5 mm). For color and translucency, $L^*$, $a^*$, and $b^*$ were measured and Two-way analysis of variance (ANOVA) and One-way analysis of variance (ANOVA) were used for data analysis (${\alpha}$=0.05). RESULTS. The higher the mixing ratio was, $L^*$, $a^*$, and $b^*$ of IPS e.max Ceram were all increased, and $L^*$ of Vintage Halo was reduced and $a^*$ and $b^*$ were increased. $L^*$ and $a^*$ of Ceramco3 were reduced and $b^*$ of Ceramco3 was increased. Color difference (${\Delta}E^*ab$) was increased in all three products as the mixing ratio got higher. Increased mixing ratios resulted in decreased translucency parameter (TP) values for IPS e.max Ceram but increased TP values for Vintage Halo and Ceramco3. CONCLUSION. In this limited study, CIE $L^*$, $a^*$, and $b^*$ were influenced by the mixing ratio of the A3 powders and porcelain powder mixtures represented a various color and translucency.

지르코니아 코어의 두께에 따른 변색치와 메탈 포스트의 색조차단 효과 (Effect of Zirconia Core Thickness on the Tone Blocking of Discolored Tooth and Metal Post)

  • 오선미;이채현
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.327-335
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the correlation between zirconia core thickness and color tone blocking of discolored tooth and metal post. Methods: For this study, we made 20-porcelain sample and 4-metal sample( liechtenstein IPS e.max) bonded to zirconia core of different thickness with cement(Relyx ARC-3M USA)for produce discolored. We measured the color-spectral characteristics, using Shadepilot equipment(Degudent USA).We measured it with Shadepilot equipment set by automated average mode in 3 times And applied the average value obtained from 2 times of measurement in the middle of each sample. Results: As a result of analysing color-spectral characteristics on zirconia core sample, Depending on the thickness of zirconia core, the value of brightness(${\Delta}L*$:color-spectral characteristic) was increased within limited range, value of ${\Delta}a*$, ${\Delta}b*$ was decrease. Conclusion: Consequently, we obtained the following results: Changes of sample color were observed depending on the thickness of zirconia, but the range of change did not exceed the scope range of shade guide. The case of metal posts, shade guide color D2 were observed in 0.5mm of zirconia core thickness. As a result, in case of porcelain, increasing the zirconia thickness of 0.3mm or more is unnecessary for color blocking effect, in case of metal post, considering the discolored tooth, thickness of zirconia with at least 0.5mm or more is recommended.