1 |
Rosenblum M: A review of all-ceramic restoration. J Am Dent Assoc 128(3): 297-307, 1997.
|
2 |
Park JH, Whang JW, Shin SW: The study of flexural strength of various zirconia ceramics. J Kor Acad Prosthodont 42(2): 142-153, 2004.
|
3 |
Albakry M, Gluazzato M, Swain MV: Fracture toughness and hardness evaluation of three pressable all-ceramic dental materials. J Dent 3(3)1: 181-188, 2003.
DOI
ScienceOn
|
4 |
Ritter JE: Engineering design and fatigue failure of brittle materials, In: Bradt RC, Hasselman DPH, Lange FF(eds), Fracture mechanics of ceramics. Vol 4, Crack growth and Microstructure. Plenum, New York, pp. 667-686, 1978.
|
5 |
Marcelo M et al.: Influence of pH on slow crack growth of dental porcelains. Dent Mater, 24(6): 814-823, 2008.
DOI
ScienceOn
|
6 |
White SN: Chanical fatigue of a feldspathic dental porcelain. Dent Mater, 9(4): 260-264, 1993.
DOI
ScienceOn
|
7 |
AndrR et al.: Fatigue of zirconia under cyclic loading in water and its implications for the design of dental bridges. Dent Mater, 23(1): 106-114, 2007.
DOI
ScienceOn
|
8 |
McCabe JF, Walls AWG: The treatment of results for tensile bond strength testing. J Dent Res 14(4): 165-168, 1986.
DOI
ScienceOn
|
9 |
De Jager N, Pallav P, Feilzer AJ: The influence of design parameters on the FEA-determined stress distribution in CAD/CAM produced all-ceramic dental crowns. Dent Mater 21(3): 242-251, 2006.
|
10 |
Petra C et al.: Shear bond strengths between different zirconia cores and veneering ceramics and their susceptibility to thermocycling. Dent Mater, 24(11): 1556-1567, 2008.
DOI
ScienceOn
|
11 |
Sundh A, Sjogren G: A comparison of fracture strength of yttrium-oxide-partially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics. J Oral Rehabil 31(7): 682-682, 2004.
DOI
ScienceOn
|
12 |
Sherrill CA, O'Brien WJ: Transverse strength of aluminous and feldspathic porcelain. J Dent Res 53(3): 683-690, 1974.
DOI
|
13 |
Ban S, Anusavice KJ: Inflence of test method on failure stress of brittle dental materials. J Dent Res 69(12): 1791-1799, 1990.
DOI
ScienceOn
|
14 |
Ban S, Hasegawa J, Anusavice KJ: Effect of loading conditions on bi-axial flexure strength of dental cements. Dent Mater 8(2): 100-104, 1992.
DOI
ScienceOn
|
15 |
Russell AG et al.: Flexural strength of feldspathic porcelain treated with ion exchange, overglaze, and polishing. J Prosthet Dent 71(5): 468-472, 1994.
DOI
ScienceOn
|
16 |
Fairhurst CW et al.: The effect of glaze on porcelain strength. Dent Mater 8(3): 203-207, 1992.
DOI
ScienceOn
|
17 |
Fairhurst CW et al.: A study of flaw size in porcelain(abstract). J Dent Res 73: 370, 1994.
|
18 |
Smyth KK, Magida MB: Dyanmic fatigue of a machinable glass-ceramic. J Amer Ceram Soc 66(7): 500-505, 1983.
DOI
ScienceOn
|
19 |
Fairhurst CW, Lockwood RD, Twiggs Sw: Dynamic fatigue of feldspathic porcelain. Dent Mater 9(4): 269-73, 1993.
DOI
ScienceOn
|
20 |
Myers ML, et al.: Fatigue failure parameters of IPS-Empress porcelain. Int J Prosth 7(6): 549-553, 1994.
|
21 |
Wachtman JB, Capps W, Mandel J: Bi-axial flexure tests of ceramic substrates. J Mater 7: 188-194, 1972.
|