• Title/Summary/Keyword: Level Evaluation

Search Result 9,817, Processing Time 0.039 seconds

Quantitative evaluation of collapse hazard levels of tunnel faces by interlinked consideration of face mapping, design and construction data: focused on adaptive weights (막장관찰 및 설계/시공자료가 연계 고려된 터널막장 붕괴 위험도의 정량적 산정: 가변형 가중치 중심으로)

  • Shin, Hyu-Soung;Lee, Seung-Soo;Kim, Kwang-Yeom;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.5
    • /
    • pp.505-522
    • /
    • 2013
  • Previously, a new concept of indexing methodology has been proposed for quantitative assessment of tunnel collapse hazard level at each tunnel face with respect to the given geological data, design condition and the corresponding construction activity (Shin et al, 2009a). In this paper, 'linear' model, in which weights of influence factors are invariable, and 'non-linear' model, in which weights of influence factors are variable, are taken into account with some examples. Then, the 'non-linear' model is validated by using 100 tunnel collapse cases. It appears that 'non-linear' model allows us to have adapted weight values of influence factors to characteristics of given tunnel site. In order to make a better understanding and help for an effective use of the system, a series of operating processes of the system are built up. Then, by following the processes, the system is applied to a real-life tunnel project in very weak and varying ground conditions. Through this approach, it would be quite apparent that the tunnel collapse hazard indices are determined by well interlinked consideration of face mapping data as well as design/construction data. The calculated indices seem to be in good agreement with available electric resistivity distribution and design/construction status. In addition, This approach could enhance effective usage of face mapping data and lead timely and well corresponding field reactions to situation of weak tunnel faces.

A Radiologic Study of the Relationship of the Maxillary Sinus Floor and Apex of the Maxillary Molar (상악동 아래벽과 상악 대구치 치근사이 위치관계에 관한 방사선학적 연구)

  • Yoon Hae-Rym;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.111-126
    • /
    • 1998
  • In this study, radiographic evaluation was made using panoramic radiography and cross-sectional tomography of SCANORA/sup (R)/ in male and female adults in their 20's on the relationship between the maxillary sinus floor and the apex of the maxillary molar, to test the accuracy and effectiveness of the cross-sectional tomography, and to use this information in the assessment of preop. and postop. root canal treatment, apical surgery, extraction and implantology. Forty-one adults with an average age of 24.4 years were studied using panoramic radiography and cross-sectional tomography. In panoramic view and cross-sectional view, the position of the apices of maxillary molars were classified as separated, contacted, or protruded type; the general shape of the maxillary sinus floor was evaluated horizontally and vertically from cross-sectional tomography. The accuracy of each radiography was tested using maxilla from 5 fresh cadavers from the Anatomy Lab at Yonsei University Dental College, and panoramic view and cross-sectional tomography were taken in the same condition as with the patients. The results were as follows: 1. Panoramic view and cross-sectional view were taken in the maxilla specimen, and the actual distance between the maxillary sinus floor and the tooth apices were measured in the specimen; the median values of the distance from the tooth apices to the maxillary sinus floor in the panoramic view, cross-sectional view and in the actual maxilla specimen were 2.83 mm, 4.51mm, and 4.l5mm, respectively. In the cross-sectional view, the measured distance was close to the actual distance but in the panoramic view, the measured distance was far from the actual distance. 2. When the results of the panoramic view and cross-sectional view were compared, 40.5% of the results agreed with each other in the two radiographic methods and buccal roots of the 2nd molar were the closest to the maxillary sinus floor in the cross-sectional tomography. 3. In cross-sectional view, when the vertical relationship of the maxillary sinus floor and maxillary roots was assessed, in 1st molars, type II (the sinus floor that extends down to the buccolingual furcation area) was predominant, while in 2nd molars, type I (the sinus floor located above the level connecting the buccal and lingual apices) was predominant. In the horizontal relationship, in 1st molars, type II (the lowest floor of the maxillary sinus located in between the buccal and lingual roots) was predominant; in 2nd molars, type I (the lowest floor of the maxillary sinus located on the buccal side of the buccal roots) and type II appeared in similar frequency. In conclusion, the SCANORA/sup (R)/ cross-sectional tomography was more effective than the frequently used panoramic view, in that the relationship of the maxillary molars and maxillary sinus floor can be evaluated more accurately and the buccolingual cross-sectional view can also be observed. And maxillary sinus floor that was close to maxillary 2nd molar had tendency to be located on buccal side than that close to 1st molar. Therefore, cross-sectional tomography is an effective and accurate method to evaluate the position of the teeth in relation to the sinus floor preoperative and can be easily used to diagnose localized periapical lesions. Also, the image quality obtained was quite satisfactory.

  • PDF

Physicochemical and Sensory Characteristics of Sesame Oils Manufactured in Korea, Japan and China (한국(韓國), 일본(日本), 중국(中國) 삼개국(三個國) 참기름의 이화학적(理化學的) 특성(特性) 및 궁능적(宮能的) 특성(特性))

  • Kim, Hyeon-Wee;Lee, Min-Jung;Kim, Ki-Hong
    • Proceedings of the EASDL Conference
    • /
    • 2004.10a
    • /
    • pp.107-129
    • /
    • 2004
  • Sesame oil has been popular for hundreds of years in Korea because of its pleasant flavor and health benefits and has been studied for its antioxidant properties and flavor preferences attributed to its manufacturing methods. The objective of this study was to investigate the qualitative properties of six commercial sesame oils (3 Korean, 2 Japanese, 1 Chinese), The fatty acids in the oil are composed of two main acids oleic acid and linoleic acid with a P/S ratio of 4.99${\sim}$5.73. Of the tocopherol isomers, ${\gamma}$-toc ranged from 23.14 to 34.85mg/100g. Lignan such as sesamin(322.91${\sim}$689.39ppm) and sesamolin (62.19${\sim}$289.82 ppm) is found predominantly in sesame oil. Sesamol (8.52${\sim}$51.21 ppm) was significantly different depending on manufacturer, observed as greatest in the Korean and least in the Japanese products. The induction period was longest in order of the Korean, Chinese, and then Japanese product. The red and yellow values in Lovibond color were highest in the Korean and lowest in the Japanese product. The major volatile compounds (in order of content) were pyrazines, phenols, aldehydes, and then furans and contained a small amount of pyrroles, thiazoles and indoles. The levels of total volatiles were greatest in the Korean and least in the Japanese product. The most abundant volatiles in the Korean product were pyrazines, whereas phenols were higher in the Chinese product compared to the others. From these results, the relationships among pyrazines, sesamol, yellowness and induction period showed positive, respectively. In sensory evaluation, Korean panelists preferred, in order, the Korean, Japanese, and then the Chinese product in strength of and preference for the sesame flavor, also ranking it best in overall acceptance. Japanese panelists found similarities in the Korean and Japanese products and gave an equal level of preference for the sesame flavor and overall acceptance. On the other hand, Chinese panelists preferred the Japanese product in strength and sesame flavor rating it best on overall acceptance.

  • PDF

A Study on Public Health Doctors' Participation in District Public Health Program of Health Sub-centers in Korea (보건지소 공중보건의사의 지역보건사업 참여 실태)

  • Lee, Jae-Chun;Park, Yong-Moon;Ahn, Song-Vogue;Lee, Hae-Young;Hwang, Jin-Won
    • Journal of agricultural medicine and community health
    • /
    • v.28 no.1
    • /
    • pp.53-66
    • /
    • 2003
  • Objectives: To investigate the state of medical care around health sub-centers, public health doctors' participation and opinion in the process of district public health programs. Methods: The study included 1,036 public health doctors who worked at health sub-center all over the country. The data were collected for Feb, 2002 using self-administered questionnaire by mail. Results: One or two doctors were working at health sub-center and 33.5% of health sub-centers was located in the region of the separation of prescription and dispensing. There were another medical facilities in 45.9% of the administrative district(eup or myon) where health sub-centers were located. The count of medical utilization went down to 14.8${\pm}$14.8 per a day in Nov, 2001 from 18.0${\pm}$15.6 in May, 2000, and the decline was much more in the region of the separation of prescription and dispensing. Among public health programs in health sub-centers, public health doctors participated mostly in preliminary medical examination for vaccination and least in health education. They participated in implementation rather than planning or evaluation of health program. Over a half of public health doctors were found to be positive that health programs implemented in their health sub-centers would promote the level of health in community people and they were willing to participate in district public health program if community people were in need. Conclusions: Recently health sub-centers are required to turn into health promotion facilities rather than medical practice facilities. Health program in health sub-centers will be advanced in both quality and quantity by turning the role of public health doctors who have provided medical services mainly into managing health program. Persistent education about managing health program and the policy to motivate participation in health program should be provided for public health doctors.

  • PDF

Simultaneous Analysis of 13 Pesticides in Groundwater and Evaluation of its Persistent Characteristics

  • Song, Dahee;Park, Sunhwa;Jeon, Sang-Ho;Kim, Ki-In;Hwang, Jong Yeon;Kim, Moonsu;Jo, Hun-Je;Kim, Deok-hyun;Lee, Gyeong-Mi;Kim, Hye-Jin;Kim, Tae-Seung;Chung, Hyen Mi;Kim, Hyun-Koo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.5
    • /
    • pp.434-451
    • /
    • 2017
  • For this study, groundwater samples for 3 years from 2011 through 2013 were collected at 106 groundwater monitoring site in Korea. These groundwater samples were analyzed for 13 pesticides such as cabofuran, pentachlorobenzene, hexachlorobenzene, simazine, atrazine, lindane (gamma-HCH), alachlor, heptachlor, chlordane (total), endosulfan (1, 2), dieldrin, endrin, 4,4-DDT. The objectives of this study were to determine the detection frequency and their concentrations of 13 pesticides and evaluate the health risk level considering ingestion, inhalation, and skin contact using concentrations of 13 pesticides in groundwater samples. An analysis was used for the simultaneous determination for 13 pesticides using GC-MS. GC-MS was performed on HP-5ms, using helium ($1ml\;min^{-1}$) as carrier gas. The average recoveries of the pesticides were from 92.8% to 120.8%. The limits of detection (LODs) were between $0.004{\mu}g\;L^{-1}$ and $0.118{\mu}g\;L^{-1}$ and the limits of quantification (LOQs) were between $0.012{\mu}g\;L^{-1}$ and $0.354{\mu}g\;L^{-1}$. 106 groundwater wells were selected. 54 wells were from well to monitor background groundwater quality and 52 wells were from well to monitor groundwater quality in industrial or contamination source area. Eight pesticides including pentachlorobenzene, lindane (Gamma-HCH), heptachlor, chlordane (total), Endosulfan (1, 2), dieldrin, endrin, and 4,4-DDT were not detected in groundwater samples. The detection frequency for hexachlorobenzene, alachlor, carbofuran and simazine was 23.4%, 11.4%, 7.3%, and 1.0%, respectively. Atrazine was detected once in 2011. The average concentrations were $0.00423{\mu}g\;L^{-1}$ for carbofuran, $0.000243{\mu}g\;L^{-1}$ for alachlor, $0.00015{\mu}g\;L^{-1}$ for simazine, and $0.00001{\mu}g\;L^{-1}$ for hexachlorobenzene. The detection frequency of hexachlorobenzene was high, but the average concentration was low. In the contaminated groundwater, the detection frequency for hexachlorobenzene, alachlor, carbofuran, simazine and atrazine was 26.1%, 21.3%, 7.1%, 1.9% and 0.3%, respectively. In the uncontaminated groundwater, detection frequency for hexachlorobenzene, carbofuran and alachlor were 20.2%, 7.5%, and 1.9% respectively. Simazine and atrazine were not detected at uncontaminated groundwater wells. According to the purpose of groundwater use, atrazine was detected for agricultural groundwater use. Hexachlorobenzene showed high detection frequency at agricultural groundwater use area where the animal feeding area and golf course area were located. Alachlor showed more than 50% detection frequency at cropping area, pollution concern river area, and golf course area. Atrazine was detected in agricultural water use area. By land use, the maximum detection frequency of alachlor was found near an orchard. For human risk assessment, the cancer risk for the 5 pesticides was between $10^{-7}$ and $10^{-10}$, while the non-cancer risk (HQ value) was between $10^{-4}$ and $10^{-6}$. For conclusion, these monitoring study needs to continue because of the possibility of groundwater contamination based on various purpose of groundwater use.

Implant stability evaluation according to the bone condition, fixture diameter and shape in the osseointegration simulated resin model (골유착 재현 레진 모델에서 골 상태 및 임플란트 형태에 따른 임플란트 안정성에 관한 연구)

  • Kwon, Taek-Ka;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.128-137
    • /
    • 2011
  • Purpose: Resonance frequency analysis, Periotest, and removal torque (RT) test were known as the methods to assess implant stability. The results of these methods are affected by the bone condition, implant diameter and shape. The purpose of this study is to access the meaning and the correlationship of the resonance frequency analysis, Periotest and RT test in osseointegration simulated acrylic resin when the engaged bone thickness and peri-implant bone defect are changed. Materials and methods: To simulate osseointegration, the fixture was fixed to an aluminum mold with a screw. Acrylic resin powder and liquid were poured into the mold for polymerization. The engaged resin thickness with implant was controlled. Simulated cortical bone thicknesses were 1, 3, 5 and 10 mm. Additional 1, 3 and 5 mm peri-implant bone defects were simulated. Three types of implants were used; 4 mm diameter implants of straight shape, 4 mm diameter implants of tapered shape and 5 mm diameter implants of tapered shape. Five fixtures per each type were tested in respective bone condition. Resonance frequency analysis and Periotest were evaluated in all bone conditions. Peak removal torque was measured at simulated cortical bone thicknesses of 1 and 3 mm. The statistical analysis was performed with the Kruskal-Wallis test, Mann-Whitney U test, and Spearman test using a 95% level of confidence. Results: With increasing engaged bone depth, the Implant Stability Quotient (ISQ) values increased and the Periotest values (PTVs) decreased (P<.001, P<.001). With increasing peri-implant bone defect, ISQ values decreased and PTVs increased (P<.001). When the diameter of implant increased, ISQ values increased and Periotest values (PTV) decreased (P<.001). There was a strong correlation between ISQ values and PTVs (r = -0.99, P<.001). Furthermore, the peak removal torque values had weak correlations with both ISQ values and PTVs (r = 0.52, P<.001 ; r = -0.52, P<.001). Conclusion: This study confirmed favorable implant stability with increasing engaged bone depth and implant diameter and decreasing peri-implant bone defect. ISQ values and PTVs showed strong correlation with each other and not with the peak removal torque values.

Comparative study of surface roughness between several finishing and polishing procedures on ormocer-based composite resin and nanohybrid composite resin (복합 레진에서 마무리 방법에 따른 표면 거칠기 비교)

  • Jeong, Suk-In;Oh, Nam-Sik;Lee, Myung-Hyeon;Lee, En-Jung;Cho, Jung-Hyeon;Ji, Sung-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.105-115
    • /
    • 2008
  • Statement of problem: Proper finishing and polishing enhance both the esthetics and the longevity of restored teeth. Blade finishing technique would be suited for smoothing and finishing. Evaluation of this technique are necessary. Purpose: The purpose of this study was to evaluate the blade finishing and polishing procedures on the surface profile and roughness of ormocer-based composite resin and nanohybrid composite resin. Material and methods: The material included a ormocer-based composite resin ($Admira^{(R)}$ & $Admira^{(R)}$ Flow); a nanohybrid composite resin ($Grandio^{(R)}$ & $Grandio^{(R)}$ Flow). One hundred forty specimens of each group were prepared using a mylar strip and randomly divied into blade finishing and rubber polishing groups (n=10). The average surface roughness (Ra) in micrometers was measured and the surface profile was examined by scanning electron microscopy (SEM) (Magnification ${\times}$ 200). The data were analyzed by Mann-Whitney Test at 0.05 significance level. Conclusion: The results of this study indicated that the mylar strip produced the smoothest surface on all materials and among the finishing-polishing methods was not significanct difference (P>0.05). Ormocer-based flowable composite resin performedthe lowest variability in initial surface roughness among the tested materials.

Case Study of Teaching Practices of Biology Teachers with and without Research Experience in Evolution Education (진화 교육 연구 경험 유무에 따른 생명과학 교사의 교수 실행 사례 연구)

  • Ko, Yuseon;Cha, Heeyoung;Lim, Mili
    • Journal of The Korean Association For Science Education
    • /
    • v.37 no.4
    • /
    • pp.747-761
    • /
    • 2017
  • The purpose of this study is to analyze differences in the teaching practices of biology teachers according to their awareness of the importance of evolution. For this purpose, two teachers who experienced study of evolution and recognized its importance, along with two teachers with no experience in evolution education in the comparison group, were included in the sample. To observe teaching practices, two classes each on biological evolution and non-evolution were selected, recorded and transcribed. The content analyzed included the teachers' view on evolution education and teachers' evolution concepts reflected in teaching practice. As a result, the level of understanding of the teachers' evolution concept was unrelated to teachers' awareness of the importance of evolution. Instead, each teacher would not feel the need for religious beliefs or awareness of the importance of evolution to have a negative impact on the awareness of the importance of evolution. Inexperienced teachers tend to reject the retraining opportunities to recognize the importance of evolution. In addition, inexperienced teachers were only superficially aware of the evaluation and improvement of evolution presented in textbooks and curricula. In actual teaching practice analysis, inexperienced teachers' utilizing ratio of the evolution key concept was higher than that of experienced teachers. Only experienced teachers were aware of the misconceptions presented in their execution and described the causes that appear in these misconceptions. Teachers who recognized the importance of evolution were widely using the key concepts of evolution, as well as more practical in preventing the misconceptions related to evolution forms. It indicates that biology teachers who do not realize the importance of evolution in biology education need to experience explicit and practical education programs as well as instructional materials on evolution.

Derivation of rock parameters from Televiewer data (텔레뷰어에 의한 토목설계 매개변수의 산출)

  • Kim Jung-Yul;Kim Yoo-Sung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.137-155
    • /
    • 1999
  • Recently, Televiewer(Borehole Acoustic Scanner(Televiewer)) has come to be widely used specially for the general engineering construction design. The Televiewer tool using a focussed acoustic beam is to detect the amplitude and traveltime of each reflected acoustic signal at the wall, resulting in the amplitude- and traveltime image respectively. Fractures can be well detected, because they easily scatter the acoustic energy due to the highly narrow beam. In addition, the drilling work will rough the borehole wall so that the acoustic energy can be scattered simply due to the roughness of the wall. Thus, the amplitude level can be directed associated with the elastic properties(impedance) and the hardness of the rock as well. Meanwhile, the traveltime image provides an information about the borehole shape and can be converted to a high precision 3D caliper log(max. 288 arms). In this paper, based on the high resolution of Televiewer images, general evaluation methods are illustrated to derive very reliable rock parameters.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.