• Title/Summary/Keyword: Level Diagnosis

Search Result 2,110, Processing Time 0.035 seconds

A study and the growth and the development of microvascular complications in patients with type 1 diabetes mellitus (1형 당뇨병 환자의 성장과 미세혈관 합병증 발생에 대한 연구)

  • Lee, Young Ah;Yun, Kyong-Ah;Shin, Choong Ho;Yang, Sei Won
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.2
    • /
    • pp.190-197
    • /
    • 2007
  • Purpose : Reduced growth and microvascular complications have been recognized as consequences of type 1 diabetes mellitus (T1DM). We assessed the effect of T1DM on growth and factors associated with the development of microvascular complications. Methods : We conducted a retrospective longitudinal evaluation of 154 patients above 16 years of age. We analyzed factors which affect final height standard deviation scores (SDS) and development of microvascular complications. Results : Final height SDS was $-0.11{\pm}1.15$ ($-0.26{\pm}1.33$ in females, $0.04{\pm}0.91$ in males). Final height SDS was significantly lower than midparental height SDS and height SDS at diagnosis. There was no difference in final height SDS according to age at onset, existence or nonexistence of complications, or average $HbA_{1C}$. Height SDS at onset of puberty, midparental height SDS and pubertal growth gain affected final height SDS. The number of patients with complications was 37 (24 percent). Microvascular complications developed at a younger age and after longer duration of diabetes in patients with a prepubertal onset of T1DM compared to patients with pubertal onset. Patients with complications had a higher level of average $HbA_{1C}$ than patients without complications. Patients whose microalbuminuria regressed had lower levels of average $HbA_{1C}$, systolic BP, second 24h urine microalbumin than patients with persistant or progressed microalbuminuria. Conclusion : The results suggest that degrees of glycemic control don't affect final height, but various factors associated with T1DM can impair growth potential. Additionally, the degrees of glycemic control and puberty affect the development of microvascular complications.

Analysis of urine β2-microglobulin in pediatric renal disease (소아 신장질환에서 요 β2-microglobulin검사의 분석)

  • Kim, Dong Woon;Lim, In Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.4
    • /
    • pp.369-375
    • /
    • 2007
  • Purpose : There have been numerous researches on urine ${\beta}_2$-microglobulin (${\beta}_2$-M) concerned with primary nephrotic syndrome and other glomerular diseases, but not much has been done in relation to pediatric age groups. Thus, our hospital decided to study the relations between the analysis of the test results we have conducted on pediatric patients and renal functions. Methods : Retrospective data analysis was done to 102 patients of ages 0 to 4 with renal diseases with symptoms such as hematuria, edema, and proteinuria who were admitted to Chung-Ang Yongsan Hospital and who participated in 24-hour urine and urine ${\beta}_2$-M excretion test between January of 2003 and January of 2006. Each disease was differentiated as independent variables, and the statistical difference of the results of urine ${\beta}_2$-M excretion of several groups of renal diseases was analyzed with student T-test by using test results as dependent variables. Results : Levels of urine ${\beta}_2$-M excretion of the 102 patients were as follows : 52 had primary nephrotic syndrome [MCNS (n=45, $72{\pm}45{\mu}g/g$ creatinine, ${\mu}g/g-Cr$), MPGN (n=3, $154{\pm}415{\mu}g/g-Cr$), FSGS (n=4, $188{\pm}46{\mu}g/-Cr$], six had APSGN ($93{\pm}404{\mu}g/g-Cr$), seven had IgA nephropathy ($3,414{\pm}106{\mu}g/g-Cr$), 9 had APN ($742{\pm}160{\mu}g/g-Cr$), 16 had cystitis ($179{\pm}168{\mu}g/g-Cr$), and 12 had HSP nephritis ($109{\pm}898{\mu}g/g-Cr$). IgA nephropathy (P<0.05) and APN (P<0.05) were significantly higher than in other renal diseases. Among primary nephrotic syndrome, FSGS with higher results of ${\beta}_2$-microglobulin test had longer treatment period (P<0.01) when compared to the lower groups, but no significant differences in Ccr, BUN, or Cr were observed. Conclusion : IgA nephropathy and APN groups showed significantly higher level of ${\beta}_2$-M excretion value than other groups. Although ${\beta}_2$-microglobulin value is not appropriate as an indicator of general renal function and pathology, it seems to be sufficient in the differential diagnosis of the UTI and in the prediction of the treat-ment period of nephrotic syndrome patients.

Clinical Study of Rhabdomyolysis After Exercise (운동 후 발생한 횡문근 융해증의 임상적 고찰)

  • Ahn, Young-Joon;Yi, Seung-Rim;Yoo, Jae-Ho;Zoo, Min-Hong;Kim, Seong-Wan;Park, Ji-Man;Yang, Bo-Kyu
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.2
    • /
    • pp.110-114
    • /
    • 2007
  • Purpose: This study evaluate clinical findings & management of rhabdomyolysis after strenuous activities in military police recruit. Materials and Methods: This study was carried out from June $1^{st}$, 2004 and May $23^{nd}$, 2005. The study subjects were 13 military police recruit patients who were admitted to our hospital with intractable muscle pain and swelling, and had suspicions of Rhabdomyolysis. The patients were given various blood tests (CPK, CK-MB, AST, BUN/Cr, and Electrolyte) and clinically observed. The patients were all males, and their average age was 20 $(19\sim21)$ years. Seven cases were due to push-up exercises, 5 was due to a soccer game, and 1 was due to riot control activities. The patients complained of swelling and tenderness in various parts of the extremities. Four complained of swelling and tenderness in forearm, 3 in upper arm, 1 in shoulder, and 5 in lower extremity. The diagnosis of rhabdomyolysis was made if the patient complained clinical symptom and had a blood CPK level of above 1,000 IU/L at the time of admission. Patients who took medication or had medical problem were excluded from this study. Bone scans were taken of all patients 4 hours after giving 99mTc-MDP 20mCi intravenously. Treatment was bed rest and fluid therapy. Patients who complained of excessive pain were given splint immobilization. Results: The average hospitalization day for the 13 patients was 20 days ($14\sim42$ days). Excluding one patient who exhibited ARF at time of admission, all patients showed a decrease of blood CPK below 1000 IU/L at an average hospitalization time of 8 days ($2\sim11$ days). The patient with ARF recovered after hemodialysis and fluid therapy. Conclusion: Patients complaining of swelling and severe muscle pain after excessive exercise or training should be suspicious of exercise induced rhabdomyolysis, and should be given blood tests and fluid therapy immediately.

  • PDF

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF

Diagnostic Ability of Tc-99m MIBI SPECT in Coronary Artery Diseases is not Affected by the Degree of Exercise (운동 정도와 무관한 Tc-99m Methoxyisobutyl Isonitrile 심근관류 스캔의 진단능)

  • Lee, Jae-Tae;Kim, Jong-Soo;Chun, Kyung-Ah;Lee, Sang-Woo;Kang, Do-Young;Cho, Yong-Keun;Chae, Shung-Chull;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.40-48
    • /
    • 1999
  • Purpose: The sensitivity of ST-depression in the electrocardiogram during exercise is influenced by the level of efforts. However, unlike the prevalence of ST-depression on exercise ECG, the degree of exercise is reported to do not influence the diagnostic ability of myocardial perfusion scan. Furthermore, the relation between the prevalence of myocardial ischemia and effort is still controversial. We evaluated the effect of the degree of exercise on the ability of SPECT imaging to detect coronary artery stenosis. Materials and Methods: The patient population was comprised of 111 patients (73 men and 38 women, mean age 56 years) who underwent an exercise test in conjunction with Tc-99m MIBI and cardiac catheterization within 3 months apart each other. The degree of exercise was classified into four groups according to the percentage of maximal predicted heart rate. The sensitivity and specificity was compared between each group. Results: The overall diagnostic sensitivity was significantly higher with Tc-99m MIBI SPECT than exercise ECG. The specificity was not significantly different between two tests. Sensitivity and specificity of Tc-99m MIBI was not different between four groups. Sensitivity for individual coronary stenosis seemed to be lower in subjects who had premature termination of exercise due to early appearance of ST depression. Conclusion: These results suggest that the overall diagnostic sensitivity of Tc-99m MIBI myocardial perfusion SPECT is not significantly affected by the degree of exercise in stable patients undergoing symptom-limited treadmill exercise testing. Myocardial perfusion SPECT imaging should be added to routine exercise stress testing for the detection of coronary artery disease.

  • PDF

Antineutrophil Cytoplasmic Antibody in Korean Children with Henoch-$Sch{\ddot{o}}nlein$ Purpura (소아 Henoch-$Sch{\ddot{o}}nlein$ 자반증에서의 항호중구 항체)

  • Choi, Ji-Na;Shin, Jae-Il;Lee, Jae-Seung;Kim, Hyon-Suk
    • Childhood Kidney Diseases
    • /
    • v.12 no.2
    • /
    • pp.164-169
    • /
    • 2008
  • Purpose : There have been some reports on the prevalence of positive antineutrophil cytoplasmic antibody(ANCA) in Henoch-$Sch{\ddot{o}}nlein$ purpura(HSP), but the results were conflicting. We performed this study to evaluate the clinical significance of ANCA(c-ANCA and p-ANCA) in Korean children with HSP. Methods : The medical records of 30 patients(13 boys and 17 girls) aged 6.0$\pm$1.9(5-12) years with a clinical diagnosis of HSP based on the EULAR/PReS criteria were reviewed retrospectively. From the years 2007 to 2008, the sera from children with acute HSP were tested for antineutrophil cytoplasmic antibodies(ANCA). The target antigens of these autoantibodies are proteinase 3(c-ANCA) or myeloperoxidase(p-ANCA). Results : Palpable purpura was seen in all 30 patients(100%), abdominal pain in 20(67%), arthralgia in 17(57%), and renal involvement in 11(37%). Laboratory findings showed leukocytosis in 4 patients(13%), thrombocytosis 18 in(60%), and elevated erythrocyte sedimentation rate in 18(60%). Anti-streptolysin O titers were elevated in 7% of the patients and no patient showed elevation of serum IgA level. The sera from 29 patients were negative for c-ANCA and p-ANCA by indirect immunofluorescence, but only one patient had weakly positive results, which became negative at follow-up. Conclusions : We conclude that c-ANCA or p-ANCA is not an important serologic marker in children with HSP, because it was neither diagnostically nor immunologically specific in children with HSP. These results suggest that ANCA are not involved in the pathogenesis of HSP in children.

A Criteria on Nitrate Concentration in Soil Solution and Leaf Petiole Juice for Fertigation of Cucumber (Cucumis sativus L.) under Greenhouse Cultivation (시설 오이의 관비재배를 위한 토양용액과 엽병즙액중 질산태 농도 기준 설정)

  • Lim, Jae-Hyun;Lee, In-Bog;Kim, Hong-Lim
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2001
  • To develope a technique for efficiently managing fertilizer for cucumber, a quick test method to quantify nitrate content in soil solution and leaf petiole juice using a simple instrument was investigated. Among the nitrate analyzing instruments such as compact ion meter, nitrate ion meter, and test strip with reflectometer, the paper test-strip used in conjunction with a hand-held reflectometer was most closely correlated with ion chromatography method in nitrate content, and then it would be suggested with a tool that a farmer can use rapidly, conveniently and accurately for nitrate analysis in a field. Nitrate content in soil solution collected by porous cup was very variable on the lapsed time after drip irrigation and the sampling positions such as soil depth and the distance from dripper. As a result, a significant correlation between nitrate contents of soil solutions and 2M KCl soil extract was not found. However, nitrate content in soil solution extracted with a volume basis (soil:water=1:2) showed the highly significant correlation with that in 2M KCl extract. Nitrate contents of cucumber leaf petiole juices was greatly different between upper and lower leaves. Eleven to sixteen positioned-leaf would be a proper sampling position to determine nitrate content in leaf petiole for evaluating nutrient state by plant tissue analysis. From the secondary regression equations between nitrate contents of soil and petiole juice and the yield of cucumber, nitrate levels for real time diagnosis were estimated as $400mg\;l^{-1}$ soil solution by porous cup. $300mg\;l^{-1}$ in a soil volume extraction, and $1400mg\;l^{-1}$ in petiole juice from spring to summer season. In addition, the maximum yield of cucumber fruit in pot test was obtained in nitrate $1500mg\;l^{-1}$ level of petiole juice, which was similar to nitrate $1400mg\;l^{-1}$ in greenhouse trial.

  • PDF

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

The Usefulness of Bone Scan in Electric Burns (전기화상에서 골스캔의 유용성)

  • Kim, Tae-Hyung;So, Yong-Seon;Kweon, Ki-Hyeon;Han, Sang-Woong;Kim, Seok-Hwan;Kim, Jong-Soon;Han, Seung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.130-138
    • /
    • 1996
  • Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as deforming to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites & bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication. There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, serum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  • PDF

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF