• Title/Summary/Keyword: Lenses

Search Result 934, Processing Time 0.035 seconds

Analysis of Physical and Antibacterial Properties of Functional Silicone Hydrogel Ophthalmic Lenses Containing Graphene Groups

  • Su-Mi Shin;Hye-In Park;A-Young Sung
    • Korean Journal of Materials Research
    • /
    • v.33 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • The physical and antibacterial properties of ophthalmic lenses fabricated by copolymerization with hydrogel monomers using two types of graphene were measured, and their usability as contact lens materials was analyzed. For polymerization, silicone monomers, including SID-OH, 3-(methacryloxy)propyl tris(trimethylsiloxy)silane, and decamethylcyclopentasiloxane, were used, and N,N-dimethylacetamide, ethylene glycol dimethacrylate as a crosslinking agent, and azobisisobutyronitrile as an initiator were added. Also, graphene oxide nanoparticle (GON) and graphene nanoplate (GNP) were used as an additive, and the physical properties of the lenses fabricated after copolymerization were evaluated. The fabricated lenses satisfied the basic physical properties of general hydrogel contact lenses and showed the characteristics of lenses with high water content, and the disadvantage of very weak durability, due to low tensile strength. However, it was confirmed that the tensile strength and antibacterial properties were greatly improved by adding GON and GNP. With GON, the oxygen permeability and refractive index of the fabricated lenses were slightly improved. Therefore, it was determined that the graphene materials used in this study can be used in various ways as a contact lens material.

Near Visual Performance of Multifocal Contact Lenses in University Students (대학생에서 멀티포컬 소프트콘택트렌즈의 근거리 시기능 유용성)

  • Jong, Woo-Cheol;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: This study was to investigate visual performance and subjective satisfaction with multifocal soft contact lenses at near works in university students. Methods: In a cross-over study design, 26 students (6 male, 20 female) who did not have any ocular disorder with at least 20/20(1.0) binocular vision were fitted with singlevision lenses (SofLens$^{TM}59$, Bausch + Lomb Co. USA) or multifocal lenses (SofLens Multifocal, Bausch + Lomb Co. USA). After 2 weeks, visual performance assessments included visual acuity, stereoacuity and contrast sensitivity function at distance and near. Near point of accommodation, accommodative facility, near point of convergence, vergence facility and near range of clear vision at near were examined. Students' satisfaction and preference were measured using survey questionaries. Results: Subjects maintained at least 20/20 binocular vision with multifocal and single-vision lenses at distance and near. There was no difference between multifocal and single-vision lenses in stereoacuity, contrast sensitivity function and vergence facility at far and near. The near point of accommodation, accommodative facility, near point of convergence and the near range of clear vision with multifocal lenses were better than single-vision lenses. On the survey questionaries, subjects reported that they preferred and satisfied with multifocal lenses with near works, and single-vision lenses with distance works. Conclusions: The majority of university students preferred multifocal to single vision lenses because multifocal lenses provided better visual performance at near works. This study suggests that multifocal lens is helpful for young adult in prolonged near works.

Comparison of Contrast Sensitivity at Near Between Functional Progressive Addition Lenses and Sigle Vision Lenses (기능성 누진가입도렌즈와 단초점렌즈의 근거리 대비감도 비교)

  • Kim, Chang-Jin;Kim, Hyun Jung;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.381-388
    • /
    • 2010
  • Purpose: This study was to compare the contrast sensitivity evaluated the visual ability at near wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition for 2 months. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses(EYE-T, Chemilens Co., Korea, ADD 0.75D) for 2 months. Corrected visual acuity at distance and near and contrast sensitivity at near were tested right after wearing functional progressive addition lenses to compare wearing single vision lenses. And we had second test after 2 months later. Results: Comparing between test and retest, contrast sensitivity at near wearing functional progressive addition lenses was improved more than wearing single vision lenses at all spatial frequency of right, left and both eyes. Conclusions: There was considered that contrast sensitivity test is useful to evaluate the visual ability as well as quality of near work and can be applied variously.

Relationship between the Deposition of Tear Constituents and the Adherence of Candida albicans according to Soft Contact Lens Materials and Pigmentation (소프트콘택트렌즈 재질과 착색에 따른 눈물성분 침착과 칸디다균 흡착의 상관관계)

  • Park, So Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.215-225
    • /
    • 2016
  • Purpose: The aim of this study was to figure out how the characteristics of soft contact lens materials and pigmentation affect the adherence of C. albicans on soft contact lenses pre-deposited with tear constituents. Methods: The adherent number of C. albicans on clear soft contact lenses (hereinafter clear lenses) and circle soft contact lenses (hereinafter circle lenses) made of etafilcon A, hilaiflcon B and nelfilcon A, respectively, was measured before and after the deposition of artificial tear. Also, bacteria adherence on lenses were observed by a scanning electron microscope. Results: Adherence of C. albicans was significantly different according to lens materials. The amount of adsorption was not different between clear lenses and circle lenses made of etafilcon A however, the number of bacteria absorption was bigger in hilafilcon B and nelfilcon A lenses. More absorption of C. albicans was found in the non-pigmented central area compared the pigmented area, and non-pigmented peripheral area has more bacterial absorption than non-pigmented central area. The number of C. albicans decreased in the case that tear protein was pre-deposited. The maintenance of antibacterial activity against C. albicans was different according to lens materials thus, etafilcon A has the longest period of its maintenance. Conclusions: It was revealed that the number of C. albicans was different according to the characteristics of lens materials, pigmentation or non-pigmentation, the pigmented area of soft contact lenses. Thus, it is suggested that the management method should be different according to the adsorption characteristics of C. albicans.

Compact Optical Systems for Space Applications

  • Biryuchinskiy, Sergey;Churayeu, Siarhei;Jeong, Yeuncheol
    • Journal of Space Technology and Applications
    • /
    • v.1 no.1
    • /
    • pp.104-120
    • /
    • 2021
  • Some optical schemes of lenses for spacecraft developed by the author are considered. The main optical characteristics of telescope lenses of various architectures are compared. We propose compact solutions of mirror, lens-mirror, and lens systems with maximum available angular resolutions and other parameters. Examples of calculating the optical systems of lenses used for various tasks both in the field of astronomy and in the field of remote sensing of the Earth and other planets are given. The example of onboard computer system is discussed. Practical recommendations on the development and use of telescope lenses are given.

Market expectations of future progressive lenses through comparison of general progressive lenses and free-form progressive lenses (일반 누진다초점렌즈와 프리폼 누진다초점렌즈의 비교를 통한 향후 누진다초점렌즈 시장의 예측)

  • Lee, Jeung-Young;Park, Jeong-Sik;Jang, Woo-Yeong
    • Journal of the Korea society of information convergence
    • /
    • v.6 no.2
    • /
    • pp.57-60
    • /
    • 2013
  • In this paper, We compared middle-aged wearer's satisfaction of progressive multifocal lens and free-form progressive multifocal lens wearers, and investigate the direction of improvement of progressive multifocal lens. We tried to predict the development direction of progressive lenses in the future. The results of the survey, satisfaction of free-form progressive multifocal lens wearers was high, compared to normal progressive lenses. The price of free-form progressive multifocal lens is expensive compared to the nomal progressive multifocal lens, but provides a wide view than nomal progressive lenses. It was confirmed that there is sufficient merit. because it can be made in individual customized to the wearer. In the near future, It is expected that free-form progressive multifocal lenses is the most popular progressive multifocal lenses to middle-aged wearers.

  • PDF

Comparative Study of Korean Letters Legibility of Progressive Lens Wearers and Single Focus Lens Wearers under the VDT Circumstance (VDT 환경에서 누진렌즈와 단초점렌즈 착용자의 한글 읽기능력 비교 연구)

  • Ku, Hye Yeon;Kim, Dal-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.195-202
    • /
    • 2012
  • Purpose: We intended to study effects of wearing the progressive lenses on legibility of Korean letters under the VDT circumstance. Methods: Fifty subjects wearing the progressive lenses and the single focus lenses were asked to find designated characters on web-pages under the VDT circumstance. We measured times for subjects to read the web-pages and numbers of missed characters, considering them as standards of legibility, and compare results of the progressive lenses with those of the single focus lenses by variables of the size and legibility of letters and the width of web-pages. Results: In case of the progressive lenses, all the times to read the web-pages and some of the numbers of missed characters increased with statistical significance. Smaller the character size, lower the legibility of character itself, and wider the width of web-page, the legibility tended to be seriously lowered by the progressive lenses. Conclusions: It is presumed that the intermediate part of progressive lenses with narrow visual field lowers the legibility of Korean letters under the VDT circumstance.

Influence of Base Curve on the Fit of Soft Contact Lenses (소프트 콘택트렌즈의 피팅에서 베이스커브의 영향)

  • Seong, Jeong-Sub;Kim, Jae-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.33-37
    • /
    • 1998
  • Lens centration was the fitting variable that was most dependent on base curve radius. Flatter lenses tended to decenter more. A flatter contact lens will likely have to move into the periphery to reach this point of stability. In most cases, the decentration was in the superior and/or temporal direction. It was also found that comfort complains were more common with flatter lenses. The optimal fits was highest with the 8.4mm base curve lens for all three ranges fit eyes decreased as base curve radius was increased. These lenses with steeper radii lead to better centration and therefore to better fit and comfort for more patients than do thin lenses with flatter radii.

  • PDF

Generalization of equivalent lens conversion and third order aberration formulae of the generalized equivalent lens system (등가렌즈 변환의 일반화와 일반화된 등가렌즈의 3차수차식)

  • 이종웅;김건수
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.305-313
    • /
    • 1996
  • Lens design method by using equivalent lenses was already introduced, but the method has a limitaion that all lenses should be in the air. Therefore, we often get improper solution in designing cemented lenses. In this study, the lens conversion from thick lens to equivalent lens and its reversal was generalized without any preconditions, and the third order aberration fomulrae were derived for the generalized equivalent lens system. The generalized equivalent lens conversion were applied to typical cemented doublet and triplet, and they show that the third order aberrations of the generalized equivalent lenses have better agreements with their corresponding thick lenses than the previous conversion method.

  • PDF

Analytical Study of the Image Reconstruction of Fourier Holograms Using Varifocal Electric-Field-Driven Liquid Crystal Fresnel Lenses

  • Kim, Taehyeon;Lee, Seung-Chul;Park, Woo-Sang
    • Current Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.115-120
    • /
    • 2020
  • A novel method is proposed for controlling the distance of an image plane in Fourier holograms using varifocal electric-field-driven liquid-crystal (ELC) lenses. Phase Fresnel lenses are employed to reduce the thickness and response time of the ELC lenses. The voltages applied to the electrodes of the ELC Fresnel lens are adjusted so that the lens has the same retardation distribution as an ideal lens. The focal length can be controlled by changing the retardation distribution with the applied voltages. Simulations were conducted for the image reconstruction of Fourier holograms with various focal lengths of the ELC Fresnel lenses. The simulation results indicate that the distance of the image plane can be properly controlled with the varifocal ELC Fresnel lens.