• Title/Summary/Keyword: Lens color

Search Result 158, Processing Time 0.029 seconds

An Vision System for Traffic Sign Recognition (교통표지판 인식을 위한 비젼시스템)

  • 남기환;배철수;박호식;박동희;한준희;나상동
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.645-648
    • /
    • 2003
  • This paper presents an active vision system for on-line traffic sign recognition. The system is composed of two cameras, one is equipped with a wide-angle lens and the other with a telephoto lends, and a PC with an image processing board. The system first detects candidates for traffic signs in the wide-angle image using color, intensity, and shape information. For each candidate, the telephoto-camera is directed to its predicted position to capture the candidate in a large size in the image. The recognition algorithm is designed by intensively using built in functions of an off-the-shelf mage processing board to realize both easy implementation and fast recognition. The results of on-road experiments show the feasibility of the system.

  • PDF

Research for Image Enhancement using Anti-halation Disk for Compact Camera Module (헤일레이션 방지 디스크를 이용한 소형 카메라 이미지 화질개선 연구)

  • Kim, Tae-Kyu;Song, In-Ho;Han, Chan-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.17 no.1
    • /
    • pp.26-31
    • /
    • 2016
  • In this paper, we propose an image quality evaluation system for compact camera module and assess the effect of optical performance improvement for proposed anti-halation disk in small lens. We develop a image quality evaluation system for quality estimation of camera module image. And we also develop a program to control register in image signal processor. Finally the resolution, brightness, and color reproduction performances were evaluated image quality comparison between conventional and proposed camera module using developed quality evaluation system and ISP register control program.

Interactive 3D Integral Imaging System using Single Camera (하나의 카메라를 이용한 인터렉티스 3D 집적 영상 시스템)

  • Shin, Dong-Hak;Kim, Eun-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.10C
    • /
    • pp.829-835
    • /
    • 2008
  • Recently, 3D integral imaging system, which is well known as an auto-stereoscopic 3D display method, has been gaining great attention amongst researchers. The integral imaging is a promising 3D display technology since it is able to deliver continuous viewing points, full parallax, and full color view to the observers in space. In this paper, we propose a novel interactive 3D integral imaging system using a single camera. The user interface is implemented by adding a camera in the conventional integral imaging system. To show the possibility of the proposed system, we implement the optical setup and present the preliminary results. To our best knowledge, this is the first time to study an interactive 3D integral imaging.

Development of Tracking Daylighting System Using Multi-Parabolic Reflector (다중 파라볼릭 반사경 방식을 이용한 추적식 집광시스템 개발)

  • Lee, Chung-Sik;Kim, Jong-Min;Park, Yeon-Min;Sung, Tae-Kyung;Joung, Che-Bong;Kang, Seung-Hoon;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.56-63
    • /
    • 2013
  • Daylighting system is an alternative lighting system using daylight collecting device, light transformer and light diffuser. In this paper, we developed a daylighting system in which the collecting device composed by dual parabolic reflectors, the silica optical fiber adapted to the light transformer and light diffuser made of the polyglass square sheet. We have estimated the system efficiency and general color rendering index(Ra) of the developed system. The system efficiency measured to 23.8% and Ra was revealed as 95. Ra number of the developed system is bigger than the number(65) of the previous fresnel lens based sunlight collector.

An Vision System for Traffic sign Recognition (교통표지판 인식을 위한 비젼시스템)

  • 남기환;배철수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.471-476
    • /
    • 2004
  • This paper presents an active vision system for on-line traffic sign recognition. The system is composed of two cameras, one is equipped with a wide-angle lens and the other with a telephoto lends, and a PC with an image processing board. The system first detects candidates for traffic signs in the wide-angle image using color, intensity, and shape information. For each candidate, the telephoto-camera is directed to its predicted position to capture the candidate in a large size in the image. The recognition algorithm is designed by intensively using built in functions of an off-the-shelf image processing board to realize both easy implementation and fast recognition. The results of on-road experiments show the feasibility of the system.

Changes of Visual Acuity and Visual Function in the Elderly Generation and their Subjective Satisfaction by the Use of Tinted Ophthalmic Lenses (착색안경렌즈의 사용에 따른 노년층의 시력 및 시기능 변화와 자각적 만족도)

  • Ryu, Deok-Hyeon;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • Purpose: The study was aimed to suggest the most effective color of the tinted lenses by evaluating the effect of the prescription with tinted lenses on the visual quality of the elderly at the age of the sixty or more. Methods: The visual acuity of fifty subjects at the age of sixty or more (17 males, 33 females with the averaged age of $71.0{\pm}6.3$) were corrected to have the visual acuity at a far distance of 0.5 or more using a trial lens frame, and non-tinted, brown-tinted, and gray-tinted lenses were randomly applied on the trial frame. The minimum legibility and minimum separability were measured at a far distance in the aspect of the visual acuity and calculated as LogMAR and then, the visual acuity was compared. The stereopsis and contrast sensitivity were also estimated at a near distance in the aspect of the visual function. The participants' preference for tinted lenses and their subjective symptoms of the visual perception and the movement were further surveyed. Results: The best minimum legibility and minimum separability was shown when wearing non-tinted lenses, and brown-tinted and gray-tinted lenses were in the next. The stereopsis and the contrast sensitivity at a near distance and the visual perception was the best when wearing brown-tinted lenses. It was surveyed that the subjective discomfort was the biggest when wearing gray-tinted lenses, and brown-tinted lenses were the best in the aspect of the subjective preference. Conclusions: As the result of this study, it was revealed that the visual acuity and visual function could be improved by the use of tinted ophthalmic lenses however, its change of visual acuity and visual function was not completely correlated with the subjective satisfaction. Therefore, the appropriate color of ophthalmic lenses should be selected in accordance with the individual visual perception and the main vision lifestyle in the elderly generation. From the present study, the use of non- or brown-tinted lens and brown- or gray-tinted lens can be recommended for distance work and near work, respectively, in the elderly generation under the illumination of about 1,000 lux.

The Study of the Characteristic of Ti Thin Film Using Small Magnetron Sputtering Method for Sunglass Lens (소형 Magnetron sputtering 방법에 의한 썬글라스 렌즈용 Ti 박막의 특성연구)

  • Park, Moonchan;Jung, Boo Young;Lee, Jong Geun;Joo, Kyung Bok;Lee, Wha Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.59-63
    • /
    • 2008
  • Purpose: Ti thin films were deposited on slide glass and CR-39 lenses using small magnetron sputtering apparatus to of Ti thin films. Methods: The thickness of Ti thin films were measured by cross section SEM, the transmittance and reflectance of them were obtained using spectrophotometer, the refractive index and extinction of them were obtained from VASE data. Results: The transmittances of Ti thin films with 60 nm, 120 nm, 140 nm thickness were a little change within the visual region from 400 nm to 750 nm, but were increased a little amount at near 400 nm. The transmittance of 60 nm, 120 nm, 140 nm Ti thickness in d-line was 30%, 25%, 20%, respectively. Also, it was shown that the refractive indices and extinction coefficients of the Ti thin films obtained from VASE were similar to those of Ti thin film offered macleod program. Conclusions: Ti films on CR-39 with these transmittances were available for sunglass lens. It was indicated that the refractive indices and extinction coefficients of the Ti thin films were decreased with the thickness of Ti thin film, for the thickness of Ti thin films was due to very thin.

  • PDF

Optical System Design of Compact Head-Up Display(HUD) using Micro Display (마이크로 디스플레이를 이용한 소형 헤드업 디스플레이 광학계 설계)

  • Han, Dong-Jin;Kim, Hyun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6227-6235
    • /
    • 2015
  • The HUD has recently been downsized due to the development of micro display and LED technology as a see through information display device, gradually expands the application areas. In this paper, using a DLP micro display device designed a compact head-up display(HUD) optical system for biocular observation of the image exhibition area 5 inches. It was analyzed for each design element of the optical system in order to design a compacted HUD. DLP, projection optical system and concave image combiner were discussed the design approach and the characteristics. Through a connection structure analysis of each optical system, detailed design specifications were set up and designed the optical system in detail. Put a folded configuration in the form of a white diffuse reflector between the projection lens and concave image combiner was designed to be independent, respectively. Distance of the projected image is adjustable up to approximately 2m ~ infinity and observation distance is 1m. Resolution could be recognized by 1 ~ 2pixels in HD($1,280{\times}720pixels$) class, various characters and symbols could be read. In addition, color navigation map, daytime video camera and thermal imaging cameras can be displayed.

Changes in Optics Content Described in the Middle-school Science Curriculum and Textbooks Accompanying Revision of the National Science Curriculum (교육과정 개정에 따른 중학교 과학 교육과정 및 교과서에 제시된 광학 내용의 변화)

  • Lee, Bongwoo;Son, Jeongwoo;Kwon, Gyeongpil
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.5
    • /
    • pp.194-202
    • /
    • 2017
  • The purpose of this study is to analyze how optics concepts and activities have changed according to the revision of the national science curriculum. For this purpose, the optics achievement standards presented in the middle-school science curriculum of the 7th curriculum, 2007 revised curriculum, 2009 revised curriculum, and 2015 revised curriculum, and the optics content presented in the textbooks developed for each curriculum, were compared and analyzed. The optics content is classified into four concepts: the process of viewing an object; light and color; reflection and refraction; and the image from a mirror and a lens. The main results are as follows: First, according to the revision of curriculum, some optics concepts have been added or removed. In particular, big changes have appeared in the concepts of "process of viewing the object", "dispersion", "reflection and refraction" and so on. Second, the content for 'image formation by a mirror and a lens' was gradually reduced, according to the revision of curriculum, and the level of activity was also adjusted. Third, attempts to present the content of textbooks in conjunction with the phenomena and tools that students can experience in everyday life have increased gradually. In addition, based on the analysis of the content of curriculum and textbooks, the implications for optics education have been discussed.

A study of the manual procedure of ocular prosthesis (의안의 제조 방법에 관한 연구)

  • Kim, Jai Min;Park, Dong Hwa;Yoo, Geun Chang;Kim, Soon Ae;Cho, Seung Kwon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.95-99
    • /
    • 2002
  • To investigate the manual procedure for custom fitting of ocular prosthesis and the cytotoxicity induced by extract solution of prosthetic eye, this study was performed. These procedures included the trial fitting of the wax model, impression molding, the an of iris color duplication, sclera mold made from the prosthetic wax model, scleral tints and vascular pattern, finishing and polishing. Inhibition of cell growth for extract solution was measured by MTT assay. Extract solution did not show the cytotoxicity. This study suggests that the manual procedure for custom fitting of ocular prosthesis is good for education of students.

  • PDF