• Title/Summary/Keyword: Lens Tube

Search Result 39, Processing Time 0.024 seconds

Visual Inspection of Tube Internal

  • Choi, Young-Soo;Cho, Jai-Wan;Kim, Chang-Hoi;Seo, Yong-Chil;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.789-792
    • /
    • 2003
  • Pipe inspection has a great importance to ensure safety for the nuclear power plant. In this paper, we designed visual inspection module for the tube internal, which diameter is 15${\sim}$20mm. And we made inspection module which consisted of CCD camera and light. And the relation between image and real world coordinate is established. Image processing is performed to calculate mapping parameter and analyze the size of defect. For the calculation of mapping parameter, experiment is performed using grid type test pattern. Acquired image is processed to extract image coordinate. Edge detection, thresholding, median filtering and morphology filtering is applied to extract grid pattern. Extracted image coordinate is used to calculate image to real world mapping. Lens distortion was considered and corrected to get exact data. Coordinate transformation data is provided for the users to recognize easily. Experiment was performed using grid type test pattern, we extracted lens distortion parameter and real coordinate of defect point. Radial distortion of lens was corrected but tangential distortion was not considered. As continuum to this study, the tangential distortion of lens is considered and improvement of analy zing technique for the tube internal be explored continuously.

  • PDF

Evaluation of a Aluminum Hyperbolic Mirror with the Diameter of 300 mm(f/1.98) by Using the Autostigmatic Null Lens System Assembled in a Fixed Tube Mount (경통고정식 자동무수차점 널 렌즈 테스트법을 이용한 직경 300 mm(f/1.98) 알루미늄 쌍곡면 거울의 형상측정)

  • Lee, Young-Hun;Jo, Jae-Heung;Rim, Cheon-Seog;Yang, Sun-Choel;Kim, Geon-Hee;Won, Jong-Ho;Jeong, Youn-Hong
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.412-419
    • /
    • 2006
  • We design and fabricate an autostigmatic null lens system assembled in a fixed tube mount in order to evaluate the shape of an aluminum hyperbolic mirror with the diameter of 300 mm and the f-number of 1.98, which is fabricated by a high precision aspherical DTM (diamond turning machine). Also, we evaluate the degree of shape of the aspherical mirror by this autostigmatic null lens testing method. The autostigmatic null lens system assembling in a fixed tube mount has several advantages of light weight, good mechanical stability, etc. The permissible fabricating limits of null lenses and a mount are determined by considering various tolerances to assure the measurement reliability.

Development and Design of the Optical System of a Night Scope (Night Scope 광학계의 설계 및 개발)

  • Lee, Dong-Hee;Lim, Yang-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.11-17
    • /
    • 2004
  • We tried to design and manufacture a night scope which is used in the leisure sports field. The whole system consists of an IR light source part, an objective lens part, an intensifier tube part and an eye_piece lens part. We designed an objective lens part to the infinite object imaging optical-system with 80mm focal-length, 40mm effective-aperture and 14mm image-field-size of which the chromatic aberration is reduced by using materials of BK7 and FD4. The resolution of this system is about 25lines/mm at the 40% MTF value criterion. The eye_piece lens is adopted goods to be used commercially to save cost of production. The design technique which gets in this development will be utilized greatly in good developments of the dot, the sight and the day/night riflescope system at the hereafter.

  • PDF

Dynamics of Electrowetting of a Liquid-Liquid Interface in a Cylindrical Tube (원형관내의 액체-액체 계면에 대한 전기습윤 현상의 동적 거동)

  • Kang, Kwan-Hyoung;Chung, Won-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.557-560
    • /
    • 2006
  • The contact angle of a meniscus and a droplet can be controlled by using electrowetting phenomena. We investigated the dynamic aspect of electrowetting for an oil-electrolyte interface formed inside a closed glass tube. A step input voltage is applied and the subsequent motion of the interface is recorded by a high-speed camera. A kind of capillary instability is observed near the three-phase contact line, which could degrade the reliability of device utilizing electrowetting such as electrowetting liquid lens. The dynamics of interface motion for different input voltages and the fluid viscosities are analyzed and discussed based on the experimental results.

  • PDF

Analysis of time-series user request pattern dataset for MEC-based video caching scenario (MEC 기반 비디오 캐시 시나리오를 위한 시계열 사용자 요청 패턴 데이터 세트 분석)

  • Akbar, Waleed;Muhammad, Afaq;Song, Wang-Cheol
    • KNOM Review
    • /
    • v.24 no.1
    • /
    • pp.20-28
    • /
    • 2021
  • Extensive use of social media applications and mobile devices continues to increase data traffic. Social media applications generate an endless and massive amount of multimedia traffic, specifically video traffic. Many social media platforms such as YouTube, Daily Motion, and Netflix generate endless video traffic. On these platforms, only a few popular videos are requested many times as compared to other videos. These popular videos should be cached in the user vicinity to meet continuous user demands. MEC has emerged as an essential paradigm for handling consistent user demand and caching videos in user proximity. The problem is to understand how user demand pattern varies with time. This paper analyzes three publicly available datasets, MovieLens 20M, MovieLens 100K, and The Movies Dataset, to find the user request pattern over time. We find hourly, daily, monthly, and yearly trends of all the datasets. Our resulted pattern could be used in other research while generating and analyzing the user request pattern in MEC-based video caching scenarios.

Development of an In-process Confocal Positioning System for Nanostereolithography Using Evanescent Light

  • Kajihara, Yusuke;Takeuchi, Toru;Takahashi, Satoru;Takamasu, Kiyoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.51-54
    • /
    • 2008
  • A novel stereolithography method using evanescent light has been proposed as a means to realize 100-nanometer resolution. An in-process measurement system with high accuracy has been introduced to the nanostereolithography apparatus. Specifically, an optical microscopic system was developed to monitor the exposure process and a confocal positioning system was established to improve the longitudinal positioning accuracy in the layer-by-layer process. A high-power objective lens, a tube lens, and a charge coupled device (CCD) were included in the optical microscopic system, whereas a laser, a high-power objective lens, a piezoelectric (PZT) stage, a condenser lens, a pinhole, and a photomultiplier (PMT) made up the confocal microscopic system. Two verification experiments were conducted, and the results indicated that the optical microscopic system had a horizontal resolution of 200 nm and that the confocal positioning system provided a depth resolution of 30.8 nm. These results indicate that nanostereolithography can be successfully performed with this system.

Absorbed Doses in Organs of the Head and Neck from Conventional Temporomandibular Joint Tomography (악관절 단층촬영시의 두경부 주요 기관의 흡수선량)

  • Cho Bong-Hae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.411-416
    • /
    • 1999
  • Purpose : This study was done to evaluate the absorbed doses in organs of the head and neck for the conventional temporomandibular joint tomography. Materials and Methods : Dosimetry was performed with 32 LiF thermoluminescent dosimeters, which were placed in a tissue-equivalent phantom when the temporomandibular joint was examined by both lateral and frontal temporomandibular joint tomography. Results : For lateral tomography, parotid gland and preauricular area towards tube showed relatively high absorbed dose of 1056.9 μGy and 519.9 μGy respectively. For frontal tomography, the two largest absorbed doses were 259.2 μGy in orbit towards tube and 212.0 μGy in lens towards tube. Conclusion : Conventional temporomandibular joint tomography showed relatively low absorbed doses on critical organs. Thus, responsible use of it may not be limited.

  • PDF

A X-ray Tube Using Field Emitter Made by Multi-walled Carbon Nanotube Yarns

  • Kim, Hyun-Suk;Castro, Edward Joseph D.;Kwak, Seung-Im;Ju, Jin-Young;Hwang, Yong-Gyoo;Lee, Choong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.392-392
    • /
    • 2011
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission.$^{1,2}$ CNT yarns have demonstrated its potential as excellent field emitters.$^3$ Extensive simulations were carried out in designing a CNT yarn-based cathode assembly. The focal spot size dependence on the anode surface of the geometric parameters such as axial distance of the electrostatic focus lens from the cathode and the applied bias voltages at the cathode, grid mesh and electrostatic focus lens were studied. The detailed computer simulations using Opera 3D electromagnetic software$^4$ had revealed that a remarkable size of focal spot under a focusing lens triode type set-up design was achieved. The result of this optimization simulation would then be applied for the construction of the CNT yarn based micro-focus x-ray tube with its field emission characteristics evaluated.

  • PDF

Advanced tube formation assay using human endothelial colony forming cells for in vitro evaluation of angiogenesis

  • Lee, Hyunsook;Kang, Kyu-Tae
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.22 no.6
    • /
    • pp.705-712
    • /
    • 2018
  • The tube formation assay is a widely used in vitro experiment model to evaluate angiogenic properties by measuring the formation of tubular structures from vascular endothelial cells (ECs). In vitro experimental results are crucial when considered the advisability of moving forward to in vivo studies. Thus, the additional attentions to the in vitro assay is necessary to improve the quality of the pre-clinical data, leading to better decision-making for successful drug discovery. In this study, we improved the tube formation assay system in three aspects. First, we used human endothelial colony forming cells (ECFCs), which are endothelial precursors that have a robust proliferative capacity and more defined angiogenic characteristics compared to mature ECs. Second, we utilized a real-time cell recorder to track the progression of tube formation for 48 hours. Third, to minimize analysis error due to the limited observation area, we used image-stitching software to increase the microscope field of view to a $2{\times}2$ stitched area from the $4{\times}$ object lens. Our advanced tube formation assay system successfully demonstrated the time-dependent dynamic progression of tube formation in the presence and absence of VEGF and FGF-2. Vatalanib, VEGF inhibitor, was tested by our assay system. Of note, $IC_{50}$ values of vatalanib was different at each observation time point. Collectively, these results indicate that our advanced tube formation assay system replicates the dynamic progression of tube formation in response to angiogenic modulators. Therefore, this new system provides a sensitive and versatile assay model for evaluating pro- or anti-angiogenic drugs.