• Title/Summary/Keyword: Lens Analysis

Search Result 766, Processing Time 0.037 seconds

Tolerance Analysis Method of Camera Optics Using Floating System (플로팅 시스템이 적용된 카메라 광학계의 공차 분석)

  • Son, Hyun Jun;Ryu, Jae Myung;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.303-309
    • /
    • 2022
  • Since the pixel size of the image sensor used in optical systems is gradually decreasing, the resolution specification of the optical system should be inevitably higher. If aberration change according to the eccentricity of a specific lens group occurs, only the amount of eccentricity of a specific lens group may be calculated with the traditional resolution adjustment method so that the aberration of the optical system is minimized to a certain extent. As a result, it is possible to increase the resolution of the optical system and to respond to a sensor with a large number of pixels. However, in the traditional method, there should be no change in specific aberration due to the eccentricity of a specific lens group. In this paper, we propose a new method to eliminate such a limitation of the traditional method in a camera optical system with a floating system, which is to choose and control the arbitrary two lens groups to easily minimize the eccentricity of the optical system in order to obtain an optical system with high resolution.

The correction of Lens distortion based on Image division using Artificial Neural Network (영상분할 방법 기반의 인공신경망을 적용한 카메라의 렌즈왜곡 보정)

  • Shin, Ki-Young;Bae, Jang-Han;Mun, Joung-H.
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.4
    • /
    • pp.31-38
    • /
    • 2009
  • Lens distortion is inevitable phenomenon in machine vision system. More and more distortion phenomenon is occurring in order to choice of lens for minimizing cost and system size. As shown above, correction of lens distortion is critical issue. However previous lens correction methods using camera model have problem such as nonlinear property and complicated operation. And recent lens correction methods using neural network also have accuracy and efficiency problem. In this study, I propose new algorithms for correction of lens distortion. Distorted image is divided based on the distortion quantity using k-means. And each divided image region is corrected by using neural network. As a result, the proposed algorithms have better accuracy than previous methods without image division.

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

A Study on the Method for the Local Transmittance Measurements of the Ocular Lens (안경 렌즈의 국소적 투과율 측정을 위한 방법에 관한 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Youk, Do-Jin;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.471-477
    • /
    • 2014
  • Purpose: We have analyzed the transmittance distribution of the ocular lens using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The transmittance of the laser which is focused on the surface of the ocular lens was measured by using the photo-detector and lock-in amplifier and analyzed. Multi-coated, uncoated, and progressive lenses were analyzed. Results: In the measurement of the progressive lens and a physical stimulated lens, local transmittance microscopy analysis showed a high degree of match with the measurement results through the optical microscope. In addition, the average value of the transmittance is reduced and the standard deviation was increased in the presence of optical defects. In unstimulated lens, there are a large impact on transmittance whether the anti-reflective coating is presence or absence in both the local transmittance microscopy and general transmittance analysis. Conclusions: The distribution of the transmittance measured by local transmission microscopy were changed when the various stimulus is applied to the lenses. These analyzes by local transmission microscopy can be utilized as a way to evaluate or determine the uniformity of the coating film or lens.

Investigation of the Current Status of Domestic Contact-Lens (국내 콘택트렌즈 시장 현황 조사)

  • Lee, Won Jin;Sung, Duk-Yong;Youk, Do Jin;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.79-87
    • /
    • 2002
  • To analyze the current status of contact-lens in domestic, we analyzed the data of "The Spectacles-wearing Rate Analysis in 1999 (Korea Gallup Research)", "Industry current status(Korea Medical Instruments Industrial cooperative}", "Export & Import current status (Korea Customs Service)", and finally reached the following conclusions. 1. The number of contact-lens wearers in domestic could be assumed 2.13 millions. 2. The size of contact lens market in domestic(on year 2000 basis) was about 25.3 billion Korean wons(\) in total ; 10.8 billion Korean wons on the basis of production unit price (Domestic Gross Production Amount-Export Amount : used the subtraction in math), 14.5 billion Korean wons on Import unit price basis. 3. According to the year 2001 data, the import amount of contact lens is 1.7 times greater than export amount of that. 4. The contact lens export status in year 2001 was Japan, Singapore, Taiwan, U.S.A, China, Hong Kong, Malaysia, Thai, - in order. Especially, the contact lens export of China has increased gradually every year since 1998, the first export year of contact lens. 5. The import status of contact lens was U.S.A, Japan, England, Indonesia, Argentina, Taiwan, Hong Kong, - in order. In addition, the consumption trend of contact lens consumers in domestic reflects that famous foreign contact lens brands were much preferred than lower price contact lens imported from several developing countries.

  • PDF