• Title/Summary/Keyword: Length measurement

Search Result 2,215, Processing Time 0.028 seconds

Calibration of the integrating sphere system for correcting the roughness effect in gauge block length measurement by using the Newton's rings interferometer (간섭무늬 분석을 통한 게이지 블록의 거칠기 효과 보정용 광산란장치 교정)

  • Kang C.S.;Kim J.W.;Cho M.J.;Kong H.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.47-48
    • /
    • 2006
  • A roughness measuring system which comprises an integrating sphere and a stabilized laser has been fabricated with the aim of measuring the roughness correction value which is necessary in gauge block measurement by optical interferometry. To calibrate the system, a Newton's ring interferometer has been introduced. The method how to calibrate the roughness measurement system has been described.

  • PDF

A Study on Measurement of Crack Length by using Laser Speckle Interferometry (레이저 스페클 간섭을 이용한 균열 길이 측정에 관한 연구)

  • Kang, Young-June;Bae, Jin-Kil;Ryu, Weon-Jae;Park, Nan-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.34-41
    • /
    • 2001
  • More accurate and fast inspection method for mechanical parts and structure is required to guarantee the safety. Conventional methods using compliance method, eddy current method, ultrasonic wave, acoustic emission for non-destructive testing in mechanical parts and structure have been performed as the method of contact with objects to be inspected. With this reason these methods have been taken relatively much time, money, and manpower. In this study, in order to overcome these shortcomings, we used In-plane Electronic Speckle pattern Interferometry(In-plane ESPI) that was full-field measurement and noncontact method. We detected the cracks of the specimen at a real time and measured the length of the crack by using In-place ESPI system. Finally, we compared this results with conventional microscope method.

  • PDF

Measurement Method of Linear Expansion Coefficient for Solid Matter using Michelson Interferometer (Michelson 간섭계에 의한 고체의 선팽창계수 측정방법)

  • Kim, Hong-Gyun;Kim, Young-Sun
    • Journal of Engineering Education Research
    • /
    • v.16 no.2
    • /
    • pp.24-30
    • /
    • 2013
  • This paper deals with the measurement theory and technique of linear expansion coefficient for solid material using Michelson interferometer. The Michelson interferometer produces interference fringes by splitting a beam of monochromatic light so that one beam strikes a fixed mirror and the other a movable mirror. When the reflected beams are brought back together, an interference pattern results. Precise distance measurements until a quarter of wave length can be made with the Michelson interferometer by moving the mirror and counting the interference fringes which move by a photo diode. This paper represents the application of Michelson interferometer for measuring infinitesimal length system and shows the measurement method of linear expansion coefficients for various materials like copper, aluminum and iron. the results are good agreement with theoretical value within margin of error for each materials.

A Study on the Measurement of the Normal Tracheal Length in Korea adults (한국성인의 기관 길이 측정에 관한 연구)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • v.28 no.8
    • /
    • pp.766-771
    • /
    • 1995
  • The trachea is defined as the airway from the inferior border of the cricoid cartilage to the top of the carinal spur. This paper would confirm the normal tracheal length of Korean adults through the actual measurement using the fiberoptic bronchoscopy. The subjects of this study were 25 patients, 13 males and 12 females between the age of 20 to 69 without abnormality on the neck, trachea, mediastinum and lung pharenchyme on the preoperative chest X-ray, who received the operations from the period of July to September, 1994. For those patients who had heart diseases, the cardiothoracic ratio was below 50%. The measurement was performed on the patients with endotracheal intubation under the general anesthesia in supine and neutral position. The tracheal length was calculated by the difference between the length from the tip of the endotracheal tube [E-tube to carina and to the needle which was inserted into the E-tube at the lower border of the palpated cricoid cartilage, by inserting the broncoscopy through the E-tube. The result was as follow : 1 The measured tracheal length for men was 11.8 0.2 cm[mean standard deviation and women was 10.5 0.3 cm, and that was longer than this [p<0.01 . The average was 11.2 1.0 cm and the standard error was 0.20 cm. 2 According to the correlation between the tracheal length to weight, height[Ht , age, and body surface area[BSA respectively, the Ht [p=0.003 , age [p=0.055 , and the BSA[p=0.017 were significant, while weight was not [p=0.314 . 3 From the regression analysis of the tracheal length[T.L. to the Ht, Age, and the BSA which were significant, the following equation was derived.i Ht : T.L.= -1.29 + 0.076 x Ht [P=0.003 ii Age: T.L.= 10.04 + 0.028 x Age [P=0.055 iii BSA : T.L.= 5.60 + 3.48 x BSA [P=0.017 iv In multi-regression : T.L. = -4.15 + 0.034 x Age + 0.085 x Ht [P=0.0002]

  • PDF

An Analysis to the Actual Condition of Tight Skirts Construction According to the Difference Between Body Size and Products Size (신체치수와 제품치수의 차이로 본 타이트 스커트의 구성 실태분석)

  • 정옥임
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.1
    • /
    • pp.1-8
    • /
    • 2000
  • In this study 61private brand skirts and 67 brand name skirts were compared to see if the skirts from the different markets were suitable for both comfort and movement. The researcher chose size 66 skirts with a waist circumference of 68~70cm and hip circumference of 92cm. The resets are as follows. (1) In the waist measurement, the minor brand skirts were made at the maximum measurement (70cm) and the department store brand skirts were at the minimum (68cm). (2) Compared with the standard back split length of 9cm for a 48cm-long skirt, the minor brand skirts had a split of only 4.5cm, while the department store brand skirts were 3cm less (split length-6cm). From this result, we see that both of them are less practical than they are supposed to be (3) For the department store skirts, the hip circumference and waist circumference show a significant correlation to skirt length (p<0.05) and back split length (p<0.001). Larger waist & hip measurements equal longer split length. For the minor brand skirts, the length of the split shows a significant correlation to the depth of the hem-line Shorter split equals smaller hem depth. From these results, it can be concluded that the two groups of skirts do not differ except for back split length and waist circumference, but regarding the split length, both of them should be modified for else of movement and comfort.

  • PDF

An Experimental Study on the Measurement Performance of Coordinate Measuring Machine (3 차원 좌표 측정기의 측정 성능에 대한 실험적 연구)

  • Lee, Seung-Pyo;Kang, Hyung-Joo;Ha, Sung-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.3
    • /
    • pp.47-54
    • /
    • 2009
  • In the manufacturing industry, there has been a significant increase in the use of coordinate measuring machines(CMM). In this paper, the sources of CMM measurement performance are discussed. The effects of workpiece position, length and orientation are analyzed by using the design of experiments. Both a fractional factorial design and a factorial design are employed to conduct the experimental study. The analysis of variance is performed to determine the significance of factors in the experiment and regression analysis is applied to make the measurement approximate model. The results show that position along the Z axis, length and orientation affect the CMM measurement performance.

High resolution linear scale using collimated LASER (레이저를 이용한 광학식 리니어 스케일의 분해능 향상에 관한 연구)

  • 박윤창;정경민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.170-174
    • /
    • 1999
  • The main scale of linear scale greatly affects on the precision of displacement measurement. Especially when needing the long range measurement, the length of main scale should be increased accordingly. In this paper, we propose a linear scale that uses laser interference pattern as main scale for long range measurement. The linear scale is similar to Michelson interferometer excepting that the reference mirror is tilted so as to obtain interference fringe pattern and a grating panel is attached on a quadratic photo diodes. Four kinds of grating having phase differences of 0, $\pi$ /4, $\pi$ /2, 3 $\pi$ /4 are arranged on the panel. The experimental results show that signals of - quadratic photo diode, A, B,$\overline{A}$ and $\overline{B}$ are cosine wavelike and successive signals have phase difference of $\pi$/4 each other. So the proposed method can achieve improved measurement resolution.

  • PDF

Measurement Uncertainty Analysis of Performance Test for Coordinate Measuring Machine (3차원 좌표 측정기 성능 시험법에 대한 측정 불확도 해석)

  • Lee, Seung-Pyo;Kang, Hyung-Joo;Ha, Sung-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.91-99
    • /
    • 2009
  • Because of both precise measurement and efficient quality control, coordinate measuring machines(CMMs) have been widely used in the industry. The purpose of this paper is to present a method to estimate the CMM measurement uncertainty using design of experiments. A factorial design is applied to carry out the performance test proposed by ISO 10360 and to investigate CMM measurement errors associated to orientation and length of the length bar. In order to assess the measurement uncertainty for the performance test, an analysis of the uncertainty components that make up the uncertainty budget has been carried out. The procedure for evaluating the uncertainty of it follows GUM ("Guide to the expression of uncertainty in measurement"). The results show that the proposed method is suitable to investigate CMM performance and determine the contribution of machine variables to measurement uncertainty.

A Comparative Analysis of the Difference between 3D Body Scan Measurements and Physical Measurements by Gender -5th Size Korea Adult Data- (3차원 스캔측정치와 직접치수간 차이의 성별 비교 -제5차 Size Korea 성인데이터를 대상으로-)

  • Han, Hyun-Sook;Nam, Yun-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.8
    • /
    • pp.1190-1202
    • /
    • 2009
  • A 3D body scan measurement (SM) is used as an alternative to physical measurements (PM) as the information for designing industrial products. This study compared the mean difference (MD) between SM and PM by gender and analyzed the causes of the difference. The data used in this study were the scan measurements and physical measurements of adults aged twenty to seventy years old of the fifth Size Korea survey. The results of this study are as follows: 1. The comparison of MD between men and women for all subjects: The measurement of the significant differences between men and women were height, neck base girth, chest girth, under-bust girth, waist girth, armscye girth, back length, and foot length. The causes of difference are the difference of body shape. 2. The comparison of MD between men and women by BMI groups: Many measurements had significant differences between men and women at normal weight and overweight but underweight. Some measurements had significant differences only at a specific BMI group because the body shape difference between men and women is revealed clearly in the group. The comparison of MD between men and women by age groups: The measurements that show significant difference at more than four age groups were neck girth, chest girth, under-bust girth, waist girth, armscye girth, and foot length. The height and abdomen girth had a significant difference in the age range of 20's and 30's. There were measurements that increase MD with an increase in age; under-bust girth and lateral shoulder length for women and lateral shoulder length for men. This comparison of MD between men and women provide the correct guidelines for the use of SM.

An Analysis of the Fitting of Plus-sized Women's Formal Jackets in On-line Shopping Malls (온라인 쇼핑몰의 플러스 사이즈 여성 정장 재킷 사이즈 실태 분석)

  • Ha, Hee-Jung
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.2
    • /
    • pp.203-215
    • /
    • 2009
  • The purpose of this study was to investigate current garment sizes of women's formal jackets, targeting plus-size women in online shopping malls, and to identify effective size information involved in online apparel purchase behaviors to overcome the short comings of current garment sizes from the perspectives of consumers. Basic 88 size formal jackets from the seven companies found on the 22 websites were collected and analyzed. The data were collected from March to October 2007, and analyzed using SPSS 14.0. The results were summarized as follows. First, there was no website using standard garment size labeling with 'bust-hip-height' set up by KS K 0051 among the 22 websites. Instead, all 22 websites used garment size labeling with figures such as 88, 99, 100, 110, and 120 or with letters such as L, XL, and XXL. The websites presented no body size, but listed garment size. Furthermore, the size information was presented differently, ranging from three items of bust circumference, upper arm length, and jacket length to six items of shoulder width, bust circumference, waist circumference, sleeve width, sleeve length, and jacket length. In addition, no website presented basic information for hip circumference, despite the jacket length covering the hips. Second, a total of 85.7% the websites listed bust circumferences in 88 garment sizes collected as 100cm. Shoulder widths were presented as 39cm or 37cm. Sleeve circumferences were addressed the same, 36cm, in all websites. Third, comparing the differences between guidance sizes and measurement sizes, only 28.5% of the web sites posted guidance sizes of shoulder widths the same as those of the measurement sizes. All web sites presented guidance sizes of bust circumstances as 1 to 5cm smaller than those of the measurement sizes.

  • PDF