• Title/Summary/Keyword: Length Standard

Search Result 1,965, Processing Time 0.026 seconds

A Study on Accalerated Vocous Condition in Siphon Spillway (싸이폰식 여수토의 진공촉진에 대한 연구)

  • 김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.6 no.2
    • /
    • pp.816-825
    • /
    • 1964
  • 1. Outline: The flow of the siphon spillway is very intricate and affected by vacuous condition. It is an intresting problem to make vacuum rapidly in_siphon, i.e, to provoke the perfect siphonaoge with the lowest water-level of overflow. The hydraulic experiments of siphon spillway have practiced at the Masan Lake, Haenam, the province of Junnam and gained rational and economical results which cannot be odtained by calculation. 2. Experiment: The model scale was a half of that of the prototype. 3. Results and discussion: In the experiments of 14 runs, washing, overflow water level, outlet, water level of cushion, phenomenon of water flying and water pressure of every part, etc. were studied. a) The relation of overflow water-level at siphon inlet and deflector When the elevation of the deflector is 10. 65m and the form of deflector O.4m long is the hypotenuse of an $45^{\circ}$ isosceles triangle, the over flow water-level is the minimum, i. e. the siphonage was excellent. There is no effect by the rising of overflow water-Ievel between 11.95m to 1O.65m of deflector elevation (in the first plan, it is 11.05m). But the overflow water-level rises remarkably in the outside region of the above limits. b) The relation of overflow water-level, the length of cushion and standard height of the base. The reduction of the length of cushion brings the rising of overflow waterlevel, and the rising of the standard height of the base brings the rising of overflow water level. For the long cushion length and low standard height of the base, it cannot be expeted to have the falling of overflow water-level. The most satisfactory data were obtained at 5.20m of the base standard height and 6.1m of the length of cushion. The first vah,le planned was 5.70 m and 4.30m.

  • PDF

Taxonomy of Preys in Natural Young Tarpon, Megalops atlanticus

  • Sung Hwoan Cho
    • Journal of Aquaculture
    • /
    • v.12 no.2
    • /
    • pp.101-105
    • /
    • 1999
  • Predater, tarpon (Megalops atlanticus) has a specific preferring preys in natural environments. To investigate this, young tarpon were captured and their stomach contents were weighed and sorted based on taxonomic groups. Average standard length and body weight for tarpon captured were 11.49 cm and 34.67 g, respectively. The average weight of the stomach contents in the tarpon was 0.83 g. The status of digestion extent of the consumed preys was 2.37 which indicated that preys were relatively well digested. The main preys in tarpon stomach were other fishes (mosquito fish and sheepshead minnow) and shrimp. Frequency occurrence of fishes in tarpon stomach was highest (P<0.05). Also, frequency occurrence of shrimp was higher than that of fly (P<0.05). Mean individual number of fish found in tarpon stomach was 2.66 per tarpon and it was higher than that of shrimp or fly (P<0.05). There was linear regression between the total weight of the consumed preys and the standard length of tarpon; Y (Total weight of preys) = 0.3151 $\times$ (Standard length of tarpon) - 2.7123, $R^2$=0.6140. Also, there was the strong linear regression between the total weight of the consumed preys and weight of the tarpon; Y (Total weight of preys) = 0.0299 $\times$ (Body weight of tarpon) - 0.0774, $R^2$=0.7882. These results indicated that the main preys for young tarpon in their natural environments were small fish composed of mosquito fish and sheepshead minnow and shrimp. And there was the stronger correlation between the total weight of preys and the body weight of tarpon than that between the total weight of preys and the standard length of tarpon.

  • PDF

Survey on Setting New Standards for Estimation of Acupoints in the Upper Limb of Normal Adults (정상(正常) 성인(成人) 남녀(男女) 상지부위(上肢部位)의 실측(實測)을 통한 혈부위(穴部位) 도량형(度量衡)의 기준(基準) 정립(定立))

  • Sung, Byoung-Sik;Kwon, O-Sang;Jeon, In-Suk;Kim, Jae-Hyo;Ahn, Sung-Hun;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.25 no.3
    • /
    • pp.1-14
    • /
    • 2008
  • Objectives : Weights and measures (度量衡) in Korean traditional medicine have been changed in many dynasties and countries. Thus, measurements of chon (寸) and cheok (尺) have been considered as symbolical meaning in recent studies on meridians and acupoints. The present study was made to settle up standard measurement by surveying length of each parts of upper limb as follows. Methods : To calculate length of 1 chon (寸), the length of each part was divided into the numbers of chon (寸) as shwon in ${\ll}$Goldo Hwangjenaegyeong-yeongchu (靈樞 骨度篇)${\gg}$; the chon (寸) length in ${\ll}$Goldo Hwangjenaegyeong-yeongchu (靈樞 骨度篇)${\gg}$ was compared with the chon (寸) length which is calculated by dividing human average hight into 75 chon. Results : Increment of length of 1 chon (寸) did not change as increment of height in subjects. Length of 1 chon (寸) in height is representative of length of 1 chon (寸) in each parts of upper limb. Conclusions : We suggest that most suitable length of 1 chon (寸)for the standard measurement of acupoint location is 2.20 ${\pm}$ 0.17 cm based on length of elbow joint to wrist joint.

  • PDF

Certification of magnification standards for the establishment of meter-traceability in microscopy (현미경의 길이표준 소급성 확립을 위한 배율 교정 시편 인증)

  • Kim J.A.;Kim J.W.;Park B.C.;Eom T.B.;Kang C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.645-648
    • /
    • 2005
  • Microscopy has enabled the development of many advanced technologies, and higher level microscopic techniques are required according to the increase of research in nano-technology and bio-technology fields. Therefore, in many applications, we need to measure the dimension of micro-scale parts accurately, not just to observe their shapes. To establish the meter-traceability in microscopy, gratings have been widely used as a magnification standard. KRISS provides the certification service of magnification standards using an optical diffractometer and a metrological AFM (MAFM). They are based on different measurement principles, and so can give complementary information for each other. In this paper, we describe the configuration of each system and measurement procedures to certificate grating pitch values of magnification standards. Several measurement results are presented, and the discussion about them are also given. Using the optical diffractometer, we can calibrate a grating specimen with uncertainty of less than 50 pm. The MAFM can measure a grating specimen of down to 100 nm pitch value, and the calibrated values usually have uncertainty less than 500 pm.

  • PDF

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

An experimental study on the performance of inverter heat pump with a variation of frequency and capillary size (인버터 열펌프의 주파수 및 모세관 길이 변화에 따른 시스템 성능특성의 실험적 연구)

  • Choi, J.M.;Kim, Y.C.;Kim, J.Y.;Bae, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-72
    • /
    • 1997
  • An experiment study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4141W(3550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of 1000mm which was optimum size for the frequency of 60Hz and ARHRAE Test condition A was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycle was invesigated by varying the length of capillary tube at each frequency levels of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency levels. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher EER, while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

A Study on Evaluation of Frost Damage of High-Flowing Concrete using Blast-Furnace Slag (철근의 적정량 산출에 관한 연구)

  • 임칠순;이규철
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.148-156
    • /
    • 2001
  • The korean Standard of the length of steel bar is 6m and 8m for building structures. This paper is to investigate the length of steel bar to reduce the loss of steel bar comparing with the steel length(6m, 8m) using today. This research shows that using of the others length of steel bar(7m, 9m) is able to reduce the loss up to 2.27%.

  • PDF

Comparative Studies on Physical and Mechanical Properties of Domestic Wood-Based Panels (국산목질판상재료(國産木質板狀材料)의 물리적(物理的) 및 기술적성질(機械的性質)에 관(關)한 비교연구(比較硏究))

  • Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.67-78
    • /
    • 1990
  • This study was performed to determine the characteristics of physical and mechanical properties of domestic wood based materials; plywood, particleboard, medium density fiberboard. Main items of tested properties were panel size, moisture content, water absorption, linear expansion and thickness swelling, glue bond shear strength, bending properties(stress at proportional limit, modulus of rupture. modulus of elasticity), tensile strength, screw holding strength, and internal bond as neccessary. the results were discussed mainly with Korean Standards. The obtained conclusions are as follows; 1. Length and width of 3mm thin plywood(3-ply) and 12mm thick plywood(7-ply) were satished with KS-standard, but thicknesses of these panels were not- passed tolerance limit except one of eight makers. 2. Length and width of particleboard and medium density fiberboard were greater than the tolerance limit value of KS standard, but the thicknesses of these panels were passed this value. 3. Moisture contents of 12mm thick and 3mm thin plywood were satisfied with KS-standard except one mill made 3mm thin plywood. 4. Moisture absortion of plywood was not passed tolerance limit of KS-standard but particleboard was satisfied with this standard value. 5. Dry and wet shear strengths in glue bond of 3mm thin plywood were not reached to KS-standard, but those of 12mm thick plywood were sufficiently satisfied with KS standrad. 6. Modulus of ruptures, parallel to grain and perpendicular to grain of plywood, and particleboard and medium density fiberboard were satisfied with KS-standard. 7. Tensile strengths, parallel to grain and perpendicular to grain of plywood were satisfied with allowance stress of US product standard PS 1-74. 8. Screw holding strength of particleboard was not reached to KS standard, but internal bond was satisfied with KS standard.

  • PDF

Research about Spec and Uniformity of Commercial Indirect Moxibustion (상용 간접구의 규격과 품질균일성에 대한 조사)

  • Kwon, O-Sang;Lee, Sang-Hoon;Cho, Sung-Jin;Choi, Kwang-Ho;Yeon, Sun-Hee;Lee, Sae-Bom;Choi, Sun-Mi;Ryu, Youn-Hee
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.53-62
    • /
    • 2011
  • Objectives : Burn is most common adverse events of moxibustion. Various kinds of components influence on the heat stimulation of commercial indirect moxa, but there are not enough investigation about the status. The purpose of this study is to investigate the 6 components to build a base data that is currently available to build a standard of an indirect moxibustion. Methods : The length and weight, density, thickness of the paper disk, diameter of the paper disk, and diameter in the paper disk hole were measured against 6 kinds of commercial indirect cautery. Results : 1. 'Seoam', 'Kihwang' and 'Taegeuk' shows uniform length than the other brands. 2. 'Dongbang', 'Kihwang' and 'Taegeuk' shows uniform weight than the other brands. 3. 'Dongbang', 'Kihwang' and 'Taegeuk' shows uniform density than the other brands. 4. 'Dongbang' and 'Kihwang' shows uniform thickness than the other brands. 5. 'Seoam', 'Dongbang' and 'Taegeuk' shows uniform diameter of disc hole than the other brands. Conclusions : As a result of investigation, 'Dongbang' and 'Kiwhang' indirect moxibustion was identified as a uniform product. This results are considered as an important base materials of the KS through commercial indirect moxibustion.

A Study on the Suggestion for the Revision of Standard Sizing System for Infant Clothing (유아복의 KS 치수체계 개정을 위한 제안 연구)

  • Jung, Myoung Sook;Suh, Chu Yeon;Lee, Jin Hee
    • Fashion & Textile Research Journal
    • /
    • v.16 no.1
    • /
    • pp.118-127
    • /
    • 2014
  • This study proposed a revision of standard sizing system for infant clothing to provide exact information for consumers and manufacturers. The size designation was set up by compensating the defect of existing system. Basic body measurement and reference body measurement were analysed according to size designation. The ages of the infants ranged from 0 to 36 month in accordance with safety standard of KC Self-Regularity Safety Confirmation. The results are as follows: Size designation for infant clothing was based on height that was basic body measurement. Chest girth, waist girth, head girth, arm length, foot length and weight were also analysed according to age of the month. It was proposed that height could be written alone and height with age of month did together for size designation. Size intervals of basic and reference body measurements were fixed as follows: size intervals are 5 cm in height, 2 cm in chest girth, 2 cm in waist girth, 1 cm in head girth, 2 cm in arm length, 0.5 cm in foot length and 2 kg in weight. The distributions of height and chest girth showed normal distributions. As height was taller, chest girth was also bigger. But the distribution of waist girth didn't show remarkable change with age of month. The distributions of arm length and weight showed remarkable difference with growth in 0~9 months, but the amount of growth variation got less in 12~18 months.