• Title/Summary/Keyword: Lee Sang Hyuk

Search Result 1,628, Processing Time 0.035 seconds

Comparison of $^{18}F$ FDG-PET and CT/MRI for the Diagnosis of Cervical Lymph Node Metastasis in Head and Neck Cancer: A Level-by-Level Based Study (두경부암 환자에서 경부 림프절 전이에 대한 $^{18}F$ FDG-PET과 CT/MRI의 진단적 정확도 비교: 림프절군에 따른 연구)

  • Yang, Yoo-Jung;Kim, Jae-Seung;Kim, Sang-Yun;Lee, Ho-Gyu;Nam, Soon-Yul;Choi, Seung-Ho;Ryu, Jin-Sook;Yeo, Jeong-Seok;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.52-61
    • /
    • 2004
  • Purpose: Cervical lymph node metastasis is the most important factor of the prognosis and therapeutic planning in head and neck cancer. With increasing interest of minimally invasive neck surgery, more accurate preoperative assessment of cervical lymph node becomes more essential. We evaluated the diagnostic accuracy of $^{18}F$ FDG-PET in the assessment of lymph node metastasis in patients with primary head and neck cancer and compared the results with those of CT/MRI. Materials and Methods: Thirty-two patients (M/F=27/5, $56{\pm}10yr$) with biopsy proven head and neck cancer (16 supraglottic cancer, 9 tongue cancer, 7 others) underwent FDG-PET and CT/MRI (25/7) within 1 month before neck dissection. Based on lymph node level, the diagnostic sensitivity and specificity of FDG PET and CT/MRI for the metastasis of cervical lymph node were compared. Results: Of 153 lymph node levels dissected in 32 patients, 32 lymph node levels of 19 patients were positive for metastasis by histopatholologic examination. The overall sensitivity and specificity of FDG-PET were 88% (28/32) and 93% (113/121), whereas those of CT/MRI were 56% (18/32) (p=0.002) and 92% (112/121), respectively. The diagnostic sensitivity and specificity of FDG-PET were different according to location of lymph node levels, and those of ipsilateral level 11 were lower than those of other levels. Conclusion: FDG-PET is more sensitive in detecting metastatic cervical lymph node in head and neck cancer than CT/MRI. FDG-PET might be useful in guiding the extent of neck dissection.

Pilot Study for the Prediction of Response to Radiotherapy Using [$^{18}F$]Fluorothymidine PET in Nasopharyngeal Cancer: Comparison with [$^{18}F$]FDG PET (비인두암에서 [$^{18}F$]Fluorothymidine PET을 이용한 방사선치료 반응도 예측을 위한 예비 연구: [$^{18}F$]FDG PET와의 비교)

  • Baek, So-Ra;Chae, Sun-Young;Kim, Hye-Ok;Lee, sang-Wook;Oh, Seung-Jun;Im, Ki-Chun;Moon, Dae-Hyuk;Kim, Jae-Seung;Ryu, Jin-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.535-542
    • /
    • 2009
  • Purpose: This study was performed to know whether [$^{18}F$]Fluorothymidine (FLT) positron emission tomography (PET) can be used to monitor early response to radiotherapy in comparison with [$^{18}F$]Fluorodeoxyglucose (FDG) PET, and to establish the optimal imaging time for prediction of therapy response. Materials and Methods: Two patients with nasopharyngeal cancer underwent serial FLT PET and FDG PET before and during radiotherapy. Three on-treatment FLT and FDG PET scans were performed on 1 week, 2 weeks and 3 weeks (at each time of 10 Gy, 20 Gy and 30 Gy delivered). The peak standardized uptake values ($SUV_{peak}$) of primary tumors were measured on FLT and FDG PET. Then, percent changes of $SUV_{peak}$ after therapy were calculated. Results: In two patients, baseline values of $SUV_{peak}$ on FDT PET were higher than those on FLT PET (FLT vs FDG; 3.7 vs 5.0, and 5.7 vs 15.0). In patient 1, FLT $SUV_{peak}$ showed 78%, 78% and 84% of decrease on 1 week, 2 and 3 weeks after treatment, whereas FDG $SUV_{peak}$ showed 18%, 52% and 66% of decrease, respectively. In patient 2, FLT $SUV_{peak}$ showed 75%, 75% and 68% of decrease, whereas FDG $SUV_{peak}$ showed 51%, 49% and 58% of decrease, respectively. Both patients reached to complete remission after radiotherapy. Conclusion: After radiotherapy, the decrease of FLT tumor uptake preceded the decrease of FDG tumor uptake in patients with nasopharyngeal cancer, and 1 week after therapy may be appropriate time for the assessment of early response. FLT PET might be more useful than FDG PET for monitoring early response to radiotherapy.

Clarithromycin Therapy for Scrub Typus (쯔쯔가무시(Tsutusgamushi)병에서 Clarithromycin의 치료 효과)

  • Kim, Soon;Jung, Eun Mi;Moon, Kyung Hyun;Yoe, Sung Yeob;Eum, Soo Jung;Lee, Joo Hyung;Jo, Sung Rae;Ma, Sang Hyuk
    • Pediatric Infection and Vaccine
    • /
    • v.9 no.2
    • /
    • pp.175-181
    • /
    • 2002
  • Purpose : Scrub typhus(tsutsugamushi disease) is a febrile disease characterized by fever, rash, eschar, lymphadenopathy. Therapy with tetracycline(doxycycline) or chloramphenicol is currently recommended for the treatment for scrub typhus. But there are limitations in usage a tetracycline(doxycycline) for scrub typhus in the children. Recently, there was a report that azithromycin, a macrolide antibiotic was used for scrub typhus in pregnant woman successfully. So we evaluated the effectiveness of the Clarithromycin, other a macrolide antibiotic, for scrub typhus. Methods : Seven patients with scrub typhus at department of internal medicine and three patients with scrub typhus at department of pediatrics Masan Fatima Hospital were involved for this study. A serologic diagnosis for scrub typhus were performed by use of passive hemagglutination test. Clarithromycin(Abbott Laboratories, North Chicago, IL, USA) was administrated orally in a daily dose of 500 mg for adult patients and 15 mg/kg/bid/day for pediatric patients. Results : There were 7 cases of adult patients, varying from 28 to 76 years of age and 3 cases of pediatirc patients, varying from 4 to 7 years of age with scrub typhus. All of cases had fever, myalgia, headache, rash, eschar. Seven cases had positive passive hemagglutination test and eight cases had abnormal liver function. Mean duration for the removal of fever after medication was 1.3 day(1~2 days) and all cases were recovered without complications. Conclusion : Our results suggest that Clarithromycin therapy may be effective for scrub typhus.

  • PDF

SEDATION EVALUATION USING BIS INDEX ASSESSMENT WITH AND WITHOUT THE ADDED SUBMUCOSAL MIDAZOLAM (점막하 Midazolam의 병용투여 시 BIS 분석을 이용한 진정 평가)

  • Lee, Young-Eun;Park, Mi-Kyung;Kim, So-Young;Kim, Yun-Hee;Jung, Sang-Hyuk;Baek, Kwang-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.91-98
    • /
    • 2007
  • The aim of this study was to examine the difference of the depth of sedation using the Bispectral index assessment with and without the added submucosal Midazolam to oral Chloral hydrate and Hydroxyzine for pediatric patients. Twenty seven sedation cases were performed in this study Selection criteria included good health(ASA I), 2 to 6 years of age, the need for sedation to receive dental treatment including anesthesia, and restorative procedure over at least two teeth. Patients were randomly classified into one group taking oral Chloral hydrate(60 mg/kg) and Hydroxyzine(1 mg/kg) and the other group recieving Chloral hydrate(60 mg/kg), Hydroxyzine(1 mg/kg) and submucosal Midazolam(0.1 mg/kg). Nitrous Oxide(50%) was used for both group during sedation. Patients were monitored using a pulse oximeter and a Bispectral monitor. A behavior scale was rated as quiet(Q), crying(C), movement(M), or struggling(S) every 2 minutes watching a recorded videotape. Analysis showed a significant difference in mean Bispectral index and SD during sedation across two groups(P<0.001). The group of patients injected with submucosal Midazolam in addition to oral Chloral hydrate and Hydroxyzine showed a lower mean Bispectral index and a narrower SD. PR and SpO2 for both groups remained within the normal values. Submucosal Midazolam improved the sedation quality by deepening sedation depth without compromising safety and enabled the sedation pattern to be kept more stable.

  • PDF

Effect of Various Forms of Floor System on Performance of Meat-type Duck and Environments of Duck House (오리사 바닥 형태가 육용오리의 생산성 및 사육환경에 미치는 영향)

  • Bang, Han-Tae;Kim, Dong-Woon;Hwangbo, Jong;Na, Jae-Cheon;Kang, Hwan-Ku;Kim, Min-Ji;Mushtaq, M.M.H.;Parvin, R.;Choi, Hee-Chul;Lee, Sang-Bae;Kang, Min;Kim, Ji-Hyuk
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.253-262
    • /
    • 2013
  • This experiment was conducted to investigate the effects of floor type and heating system on performance, housing environment and health status of ducks reared in three types of duck house (OD : Open floor house-Direct heating system, OF : Open floor house-Floor heating system and LD : Loft type house-Direct heating system). In OF treatment, PVC pipes were installed for heating under concrete floor and covered with litter. In LD treatment, plastic mesh was installed 50 cm above the floor so that duck's droppings can pass through it. Each treatment had four replicates of 25 birds (Cherry Valley duck breed) per pen. There were no significant differences in weight gain and feed intake of ducks for 6 weeks among all treatments. However, feed conversion ratio in LD was significantly higher (p<0.05) than that in OF. No differences were found in carcass charac- teristics, with the exception of abdominal fat weight where OF were higher than the others. Concentrations of $CO_2$ and $NH_3$ gas in OD were higher than those of OF and LD at 3, 4 and 5 weeks. Moisture content in litter of OF was lower than that of OD. In contrast, the amount of dust in the air was higher in OF than in OD. The amount of fuel used for 6 weeks in LD was lower about 21% than that in OD. Some of unusual symptoms were observed in open floor house and loft type house, such as lying, spraddle legged, twisted ankle and legs, wounded sole, or etc. No components of leukocyte and erythrocyte of blood were significantly different among all treatments. The results of this experiment showed that OF and LD systems had no positive effects on performance of meat type commercial duck. However, there were some positive effects of certain house type for the improvement of environmental condition in duck house for hygienic production. In the future, more research on the effect of various facilities and systems for duck house is needed.

THE EFFECT OF SMEAR LAYER TREATMENT ON THE MICROLEAKAGE (Smear layer 처리에 따른 미세누출에 대한 연구)

  • Lee, Jung-Min;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.378-389
    • /
    • 2006
  • The purpose of this study was to compare the sealing ability of root canal obturation with or without the treatment of smear layer. Eighty extracted human teeth with one canal were selected Instrumentation was performed with crown-down technique. After instrumentation, root canals of the NaOCl group and NaOCl-6 group were irrigated with 3% NaOCl. EDTA group and EDTA-6 group were irrigated with 17% EDTA. Then all teeth were obturated using continuous wane obturation technique NaOCl group and EDTA group were immersed in methylene blue solution for 84hours. NaOCl-6 group and EDTA-6 group were immersed in methylene blue solution for 6months. The teeth were sectioned at 1.5 mn (Level 1), 3.0 mm (Level 2) and 4.5 mm (Level 3) from the root apex. The length of dye-penetrated inter-face and the circumferential length of canal at each level were measured using Sigma-Scan Pro 5.0. 1. The mean leakage ratio was decreased cervically. 2. NaOCl group showed higher mean leakage ratio than EDTA group at each level. But there was significant difference at level 1 only (p < 0.05). 3. NaOCl-6 group showed higher mean leakage ratio than EDTA-6 group at each level. But there was significant difference at level 1 only (p < 0.05). 4. NaOCl-6 group showed higher mean leakage ratio than NaOCl group at each level. But there was significant difference at level 1 only (p < 0.05). 5. EDTA-6 group showed higher mean leakage ratio than EDTA group at each level. But there was no significant difference. 6. In NaOCl group and NaOCl-6 group, scanning electron micrographs of tooth sections generally covered with smear layer. In EDTA group and EDTA-6 group, tooth sections showing the penetration of sealers to opened dentinal tubules. The results suggest that removal of smear layer was effective to reduce the apical microleakage of the root canal.

Surface Characteristics and Spontaneous Combustibility of Coal Treated with Non-polar Solvent under Room Temperature (상온에서의 용매 처리를 통한 저등급 석탄의 표면물성 및 자연발화 특성 변화)

  • Jo, Wan Taek;Choi, Ho Kyung;Kim, Sang Do;Yoo, Ji Ho;Chun, Dong Hyuk;Rhim, Young Joon;Lim, Jeong Hwan;Lee, Si Hyun
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.609-614
    • /
    • 2013
  • This study investigated the spontaneous combustion behavior of solvent-treated low rank coals. Indonesian lignite (a KBB and SM coal) and sub-bituminous (a Roto coal) were mixed with non-polar 1-methyl naphthalene (1MN) either by mechanical agitation or ultrasonication. The property change associated with 1MN treatment was then analyzed using proximate analysis, calorific value analysis, Fourier transform infrared (FT-IR), X-ray photoelectron spectroscopy and moisture re-adsorption test. Susceptibility to spontaneous combustion was evaluated using crossingpoint temperature (CPT) measurement along with gas analysis by GC. A FT-IR profile showed that oxygen functional groups and C-H bonding became weaker when treated by 1 MN. XPS results also indicated a decrease of the oxygen groups (C-O-, C=O and COO-). Increased hydrophobicity was found in the 1MN treated coals during moisture readsorption test. A CPT of the treated coals was ${\sim}20^{\circ}C$ higher than that of the corresponding raw coals and the ultrasonication was more effective way to enhance the stability against spontaneous combustion than the agitation. In the gas analysis less CO and $CO_2$ were emitted from 1MN treated coals, also indicating inhibition of pyrophoric behavior. The surface functional groups participating in the oxidation reaction seemed to be removed by the ultrasonication more effectively than by the simple mechanical agitation.

Experimental study on the ground subsidence due to the excavation of a shallow tunnel (경사지반에서 얕은터널의 굴착에 따른 지표침하에 대한 실험적 연구)

  • Park, Chan Hyuk;Lee, Sang Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.761-778
    • /
    • 2017
  • The need of the underground space for the infrastructures in urban area is increasing, and especially the demand for shallow tunnels increased drastically. It is very important that the shallow tunnel in the urban area should fulfill not only its own safety conditions but also the safety condition for the adjacent structures and the surrounding sub-structure. Most of the studies on the behavior of shallow tunnels concentrated only on their behaviors due to the local deformation of the tunnel, such as tunnel crown or tunnel sidewall. However, few studies have been performed for the behavior of the shallow tunnel due to the deformation of the entire tunnel. Therefore, in this study the behavior of the surrounding ground and the stability caused by deformation of the whole tunnel were studied. For that purpose, model tests were performed for the various ground surface slopes and the cover depth of the tunnel. The model tunnel (width 300 mm, height 200 mm) could be simulationally deformed in the vertical and horizontal direction. The model ground was built by using carbon rods of three types (4 mm, 6 mm, 8 mm), in various surface slopes and cover depth of the tunnel. The subsidence of ground surface, the load on the tunnel crown and the sidewall, and the transferred load near tunnel were measured. As results, the ground surface subsided above the tunnel, and its amount decreased as the distance from the tunnel increased. The influence of a tunnel ceased in a certain distance from the tunnel. At the inclined ground surface, the wider subsidence has been occurred. The loads on the crown and the sidewall were clearly visible, but there was no effect of the surface slope at a certain depth. The load transfer on the adjacent ground was larger when the cover depth (on the horizontal surface) was lager. The higher the level (on the inclined surface), the wider and smaller it appeared. On the shallow tunnel under inclined surface, the transfer of the ambient load on the tunnel sidewall (low side) was clearly visible.

Manufacture of Cutting-Gouda Cheese using Lactobacillus rhamnosus_p1 and the Physicochemical Properties of Gouda Cheese during Ripening Periods (Lactobacillus rhamnosus_p1을 이용한 절단형 고다치즈 제조방법 및 숙성 중 품질특성)

  • Park, Jong-Hyuk;Jung, Hoo-Kil;Moon, Hye-Jung;Oh, Jeon-Hui;Lee, Joo-Hee;Kim, Myung-Kon;Na, Sang-Eon;Kim, Youn-Jeong;Hwang, Young-Tae
    • Journal of Dairy Science and Biotechnology
    • /
    • v.32 no.2
    • /
    • pp.131-139
    • /
    • 2014
  • The aim of this study was to manufacture Cutting-Gouda cheese and to investigate the change in physicochemical properties of Cutting-Gouda cheese made with Lactobacillus rhamnosus_p1. Lactic acid bacteria were isolated from Gouda cheese ripened for more than 1 year. They were identified as 2 strains of L. rhamnosus, Lactobacillus casei, Lactobacillus curvatus, and Staphylococcus saprophyticus by 16S rDNA sequencing and named L. rhamnosus_p1, L. casei_p2, L. curvatus_p3, L. rhamnosus_p4 and S. saprophyticus_p5. The proteolytic activities of isolated strains against casein were measured using prepared skim milk agar plates. L. rhamnosus_p1 showed the highest proteolytic activity. Cutting-Gouda cheese was made with L. rhamnosus_p1, and its physicochemical properties (moisture, protein, fat, ash and free amino acid content) were measured during ripening periods. Because of the modified atmosphere packaging ($N_2{^-}$), there was no change in moisture, protein, fat, and ash in the experimental group. The total amount of free amino acids in the control and experimental group gradually increased during ripening periods. The sensory evaluation showed that the experimental group was preferable to the control group. This result suggests that L. rhamnosus_p1 has potential to be developed as a new starter for Gouda cheese.

  • PDF

Usefulness of Ultrasonographic Examination in Diagnosis and Follow-up of the Frozen Shoulder (동결견의 진단과 치료 경과 판정에 대한 초음파 검사의 유용성)

  • Choi, Chang-Hyuk;Kim, Seok-Jun;Lee, Sang-Hwa;Kim, Hee-Soo;Shim, Jung-Hyun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose: In order to know the effectiveness of ultrasonographic examination in diagnosis and follow-up evaluation for the frozen shoulder, we compared those with contralateral side in initial and after steroid injection. Materials and Methods: For the 20 unilateral frozen shoulder from July 2012 to July 2013, ultrasonographic examination was tried using reference line 1 (CBT: distance from coracoid process to LHB tendon) and line 2 (CBG: distance from coracoid process to bicipital groove). We tried 1 time steroid injection and compared the improvement in gross motion and reference line with 2 month, 4 month, and 6 month's serial ultrasonographic examination. Results: The differences on CBT line between lesion side and normal side were -5.6 mm, -5.0 mm, and -4.3 mm in neutral (Neut), external rotation (ER) and internal rotation (IR), respectively. The differences on CBG line were -6.1 mm, -4.7 mm, and -5.0 mm respectively (p<0.05). The changes in the reference line after steroid injection were evaluated at 2 month (CBT: -4.8 mm, -3.5 mm, -2.6 mm / CBG: -4.7 mm, -4.0 mm, -3.6 mm), 4 month (CBT: -4.7 mm, -3.2 mm, -1.7 mm / CBG: -4.3 mm, -3.7 mm, -1.2 mm), and 6 month (CBT: -1.1 mm, -2.9 mm, -0.5 mm / CBG: -1.2 mm, -0.7 mm, -0.9 mm). The gross motion was improved at 4 month after injection, from elevation $108^{\circ}$, ER $32^{\circ}$, IR L5 in initial to $133^{\circ}$, $42^{\circ}$, L3 respectively (p<0.05). Pain improved from 7.5 in initial to 3.0 at 2 month on visual analog scale (VAS). Conclusion: The serial examination after steroid injection revealed that the delayed improvement on reference line (6 month) compared with pain (2 month) or gross motion (4 month). Dynamic ultrasonogram was useful in diagnosis and follow-up evaluation of frozen shoulder.

  • PDF