• Title/Summary/Keyword: Lean limit

Search Result 148, Processing Time 0.024 seconds

Effect of Swirl Angles and Combustion Characteristics of Low Swirl Model Combustor (저선회 모델 연소기의 연소특성 및 선회각도 영향)

  • Jeong, Hwanghui;Lee, Keeman
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.40-49
    • /
    • 2016
  • This study aims to confirm the characteristics of low swirl combustion at our low swirl model combustor. To do it, it is experimentally conducted by evaluating the flame shape, stability region and emissions according to the swirl angle. The most significant feature of low swirl combustion is a occurrence of lifted flame. Such lifted flames happen to combine exquisitely propagating feature of premixed flame with diverging flow. This feature of lifted flame was confirmed through a velocity flow field and visualized the flame in this model combustor. The visualized flame was classified according to the thermal power and equivalence ratio. The variation study in swirl angles showed that the lean flammable limit could be extended only by swirl angles. Also, as the swirl angle increased, it was confirmed that the NOx and CO emissions were decreased due to the mixing enhancement and shorter resident time.

A Study of Flame Visualization of the APU Gas Turbine Engine Sector Combustor (APU용 가스터빈 엔진 분할연소기의 화염가시화 연구)

  • Kim, Bo-Ra-Mi;Choi, Chea-Hong;Choi, Seong-Man
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.4
    • /
    • pp.11-17
    • /
    • 2011
  • In order to see flame behavior in the annular reverse gas turbine combustor, sector combustion test was performed. Ignition test by using torch ignition system was carried out at various combustor inlet velocity and air fuel ratio. Also, flame blow out limit was measured by changing fuel flow rate with constant air mass flow rate. In test results, stable ignition is possible at air excess ratio of 6 and this limit is gradually increased with combustor inlet velocity. The minimum blow out limit is about 4 at 40 m/s of combustor inlet velocity. This blow out limit is also increased up to about 10 with increasing combustor inlet velocity. Test result shows that lean blow out limits are increased with air velocity. The highest blow out limit was found at the combustor inlet velocity of 65 m/s.

A Study of Flame Visualization of the APU Gas Turbine Engine Sector Combustor (APU용 가스터빈 엔진 분할연소기의 화염가시화 연구)

  • Kim, Bo-Ra-Mi;Choi, Chea-Hong;Choi, Seong-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.153-159
    • /
    • 2010
  • In order to see the flame behavior in the annular reverse gas turbine combustor, sector combustion test was performed. Ignition test by using torch ignition system was carried out at the various combustor inlet velocity and air fuel ratio. Also, flame blow out limit was measured by changing fuel flow rate with constant air mass flow rate. In the test results, stable ignition is possible at air excess ratio of 6 and this limit is gradually increased with combustor inlet velocity. The minimum blow out limit is about 4 at 40 m/s of combustor inlet velocity. This blow out limit is also increased up to about 10 with increasing combustor inlet velocity. Test result shows that lean blow out limits are increased with air velocity. The highest blow out limit was found at the combustor inlet velocity of 65m/s.

  • PDF

Vibration Characteristics of Lean Premixed Flame Anchored by a Hydrogen Pilot Flame in a Tube (파일롯 화엄에 의해 고정된 관내 예혼합 화염의 진동 특성)

  • Guahk, Young-Tae;Oh, Kwang-Chul;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.42-48
    • /
    • 2004
  • Lean laminar premixed propane and methane flames which were anchored by a hydrogen-pilot flame in a tube were investigated experimentally. The flame shapes were observed by varying mean velocity from 10cm/s to 140cm/s and equivalence ratio from 0.45 to 0.8. In this study, behaviors of flames are divided into five regions such as tail-out, flash-back, flickering, stable and vibrating flames with respect to the mean velocity and the equivalence ratio. Although the flames are unstable in both the flickering and the vibrating region, they have different characteristics such as the frequency, sound generation and creation process of flame curvature. The flickering region exists near the flammability limit and the flame flickers in a frequency of about 10Hz. When flame front is bended, the propane flame front is straightened and the methane flame front is bended more by thermo-diffusive instability. In the vibrating region, the flame vibrates emitting audible sound in a frequency of about 100Hz. In the boundary of vibrating region, the vibration of flame changes between two modes such as single frequency vibration and dual frequency vibration. Increase and decrease of vibration in each mode are determined by thermo-acoustic instability.

  • PDF

Performance and Emission Characteristics of Compression Ignition Gasoline Engine (압축점화 가솔린기관의 성능 및 배기특성)

  • Kim, Hong-Sung;Kim, Mun-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.1007-1014
    • /
    • 2003
  • This work deals with a controlled auto-ignition (CAI) single cylinder gasoline engine, focusing on the extension of operating conditions. The fuel is injected indirectly into electrically heated inlet air flow. In order to keep a homogeneous air-fuel mixing, the fuel injector is water-cooled by a specially designed coolant passage. Investigated are the engine performance and emission characteristics under the wide range of operating conditions such as 32 to 63 in the air-fuel ratio, 1000 to 1800 rpm in the engine speed, and 150 to 18$0^{\circ}C$ in the inlet air temperature. The compression ignition gasoline engine can be achieved that the ultra lean-burn with self-ignition of gasoline fuel by heating inlet air. For example. the allowable lean limit of air-fuel ratio is extended until 63 at engine speed of 1000 rpm and inlet air temperature of 17$0^{\circ}C$. It can be achieved that the emission concentrations of carbon monoxide, hydrocarbons and nitrogen oxide had been significantly reduced by CAI combustion compared with conventional spark ignition engine.

RADICAL IGNITION TECHNIQUE IN A CONSTANT VOLUME CHAMBER

  • Park, J.S.;Ha, J.Y.;Yeom, J.K.;Lee, J.S.;Lee, C.J.;Chung, S.S.
    • International Journal of Automotive Technology
    • /
    • v.8 no.3
    • /
    • pp.269-274
    • /
    • 2007
  • A prior fundamental study was executed using a constant volume chamber (CVC) to improve the burning characteristics of lean pre-mixture by the injection of active radicals generated in the sub-chamber of the CVC. The Radical ignition (RI) technique shows remarkable progress in the burning velocity and combustible lean limit compared with the results of the spark ignition (SI) technique. The optimum design value of the sub-chamber geometry is near $0.11cm^{-1}$ for the ratio of the total area of the holes to the sub-chamber volume $(A_h/V_s)$. In this study, based on the former experimental results, the additional works have been performed to examine the effects of the geometry change in the number $(N_h)$, the total section area $(A_h)$, and diameter $(D_h)$ of the passage holes on the combustion characteristics in the CVC. Also ambient conditions such as the initial temperature and the initial pressure of the mixture were selected as experimental parameters and the effects of residual gas at the chamber on the combustion characteristics were investigated. As a result, the correlation between the passage hole number and overall passage hole area was grasped. The effects of the initial temperature were significant, but on the other hand, those of the initial pressure were weak. A more detailed analysis on the residual gas is required in the future.

An Innovative Public Project Process Management For the Government Owner (발주자 입장에서 바라본 혁신적인 관급공사 관리 프로세스 제시를 위한 기초 연구)

  • Kim, Sung-Won;Kim, Dea-Young
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.557-562
    • /
    • 2008
  • In Korean construction industry, a public sector's ordering volume has been constantly increased after 2000. But, because a cost, schedule and quality control generally depends on a result-centric management form and a transparent management is not done during the construction in the Korean public business, it is recognized that this causes problems including an increase of cost and schedule, incomplete construction, a difficulty to find the problem in advance to establish measures, and an unclear locus of responsibility of constructor, supervisor and designer. Accordingly, this study is intended to derive the problems and the limit of management by identifying and analyzing the management state of the present government construction client for the client organization of public sector's government construction. Also, the study is intended to contribute to the client's efficient and actual project management by presenting the model of supplementing or improving the derived problem and limits to the client's organization.

  • PDF

A Study on the Optimization of Combustion and Emission Performance in a Heavy-duty HCNG Engine (Heavy-duty HCNG엔진의 연소 및 배기성능 최적화에 관한 연구)

  • Choi, Young;Park, Chul-Woong;Won, Sang-Yeon;Kim, Chang-Gi
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.15-20
    • /
    • 2011
  • Although CNG is able to meet the current emission standards, it is expected to be impossible to satisfy the requirements of the next EURO-6 emission regulation without an additional after-treatment device. Hydrogen is known to be a gaseous fuel which features the wide flammability limit and the fast reactivity. A certain amount of hydrogen addition to CNG is able to extend the lean combustion range and produce lesser amounts of harmful emissions. In this research, the combustion and emission characteristics of HCNG(mixture of Hydrogen and CNG) fuel were experimented in an 11-liter heavy duty lean burn engine varying hydrogen contents, air-to-fuel ratio and spark timing. The optimization of this HCNG engine for a city bus was performed through the evaluations of oxidation catalyst characteristics.

Limit Cycle Amplitude Prediction Using Results of Flame Describing Function Modeling (화염묘사함수 모델링 결과를 이용한 한계 진폭 예측)

  • Kim, Jihwan;Kim, Jinah;Kim, Daesik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.6
    • /
    • pp.46-53
    • /
    • 2016
  • It is required to predict a limit cycle amplitude controlled by system's nonlinear behavior as well as an eigen-frequency and initial growth rate of instabilities under the linear motions, in order to fully understand combustion instabilities in a lean premixed gas turbine combustor. Special focus of the current work is placed on the limit cycle amplitude prediction using flame describing function(FDF) where the ratio of a heat release fluctuation to a given flow perturbation is expressed as a function of frequency and amplitude. In this study, the CFD modeling work based on RANS is carried out to obtain FDF, which makes that the nonlinear thermo-acoustic model is successfully developed for predicting the limit cycle amplitude of the combustion instability.

다공성 물질에 의한 열재순환 화염에 관한 실험적 연구 I

  • 유영돈;민대기;신현동
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1113-1120
    • /
    • 1988
  • This paper presents the results of an experimental investigation on one dimensional excess enthalpy flame formed in a porous block. The investigation is undertaken in order to further the physical understanding of internal heat recirculation from reaction zone to unburned mixture. Two porous blocks are placed at both sides of combustion block to control the temperature distribution in the combustion block by means of radiation heat transfer. Mean temperature measurement reveals the general nature of the reaction zone in the porous material. It is conformed that the temperature of reaction zone exceeds the adiabatic flame temperature and the flame is stabilized at the out range of flammibility limit derived by conventional burner.