• Title/Summary/Keyword: Leaks

Search Result 445, Processing Time 0.025 seconds

A study on Improved Convergence Security Monitoring System model (융합보안관제시스템 개선에 관한 연구)

  • Lee, Dong-Hwi;Ha, Ok-Hyun
    • Convergence Security Journal
    • /
    • v.11 no.5
    • /
    • pp.3-12
    • /
    • 2011
  • According to the NIS, damages due to leaking industrial technology are reaching tens of trillion won. The type of damages are classified according to insider leaks, joint research, and hacking, illegal technology leaks and collaborated camouflaged. But 80% of them turned out to be an insider leak about connecting with physical security. The convergence of IT and non IT is accelerating, and the boundaries between all area are crumbling. Information Security Industry has grown continuously focusing Private Information Security which is gradually expanding to Knowledge Information Security Industry, but Information Security Industry hereafter is concentrated with convergence of IT Security Technology and product, convergence of IT Security and Physical Security, and IT convergence Industry Security. In this paper, for preventing company information leaks, logical security and physical security both of them are managed at the same level. In particular, using convergence of physical security systems (access control systems, video security systems, and others) and IT integrated security control system, convergence security monitoring model is proposed that is the prevention of external attacks and insider leaks, blocked and how to maximize the synergy effect of the analysis.

A Study on the decision of Scattering distance by Shape of Fragments in LPG Tank lorry Explosion (LPG 탱크로리 폭발시 파편 형상에 따른 비산거리 산정에 관한 연구)

  • Lee, Young Jin;Hwang, Yong Woo;Lee, Ik Mo;Moon, Jin Young
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.2
    • /
    • pp.29-34
    • /
    • 2017
  • LPG is a substance that requires a lot of attention because it can cause fatal damage to people and environment when an accident occurs. LPG is frequently accidents in transportation facilities as well as fixed facilities, among which LPG tank lorries are the most frequent accidents. When the LPG tank is evacuated, the LP gas leaks into two phases, leaks mostly to the gas and leaks to some liquid. At this time, the leaked gas will also sink downward because it is heavier than air, and if it continues to leak, it may form an explosion and explode by the ignition source. The purpose of this study is to present the evacuation distance by analyzing the effect distance of the LPG liquefied petroleum gas in the event of explosion. As a result of calculation of the scattering radius of the fragment, the cylinder fragment was scattered up to 561 m. Therefore, it is appropriate to set the distance to be escaped when the LPG tanker leaks to 561m or more.

Analysis of Elastic Wave Based Leakage Detection Technology Using Accelerometers (가속도계를 이용한 탄성파 기반 누수탐지 기술 분석)

  • Choi, Kwangmook;Lee, Hohyun;Shin, Gangwook;Hong, Sungtaek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1231-1240
    • /
    • 2020
  • Water pipes are laid on the ground, making it impossible to visually detect leaks due to aging of pipes, and technology to detect leaks in pipes is mainly used to detect leaks in pipes by detecting leaks. In this paper, two accelerometers were attached to both ends of the constant water piping to calculate the time difference between the acquired data to detect leakage points. The leak test of piping was performed by installing valves at 4.3m, 8.6m, and 12.9m points on piping 17.2m, and changing the development rate of valves to 30% and 70%. Leakage can be detected for pressure drop in piping, which is 30% and 70% open valve. It is very important to detect leakage in the early stage, and it is judged that detection of the initial leak point from the algorithm applied in this paper will be possible.

Post Laparoscopic Cholecystectomy Biloma in a Child Managed by Endoscopic Retrograde Cholangio-Pancreatography and Stenting: A Case Report

  • Tiwari, Charu;Makhija, Om Prakash;Makhija, Deepa;Jayaswal, Shalika;Shah, Hemanshi
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.19 no.4
    • /
    • pp.281-285
    • /
    • 2016
  • Laparoscopic cholecystectomy, though an uncommon surgical procedure in paediatric age group is still associated with a higher risk of post-operative bile duct injuries when compared with the open procedure. Small leaks from extra hepatic biliary apparatus usually lead to the formation of a localized sub-hepatic bile collection, also known as biloma. Such leaks are rare complication after laparoscopic cholecystectomy, especially in paediatric age group. Minor bile leaks can usually be managed non-surgically by percutaneous drainage combined with endoscopic retrograde cholangio-pancreatography (ERCP). However, surgical exploration is required in cases not responding to non-operative management. If not managed on time, such injuries can lead to severe hepatic damage. We describe a case of an eight-year-old girl who presented with biloma formation after laparoscopic cholecystectomy who was managed by ERCP.

Traumatic cerebrospinal fluid leakage following septorhinoplasty

  • Youssef, Ahmed;Ahmed, Shahzad;Ibrahim, Ahmed Aly;Daniel, Mulvihill;Abdelfattah, Hisham M.;Morsi, Haitham
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.379-383
    • /
    • 2018
  • Septoplasty/septorhinoplasty is a common ear, nose and throat procedure offered for those patients with deviated septum who are suffering from nasal obstruction and functional or cosmetic problems. Although it is a basic and simple procedure, it could lead to catastrophic complications including major skull base injuries which result in cerebrospinal fluid (CSF) leaks. We describe two different cases of traumatic CSF leaks following septoplasty/septorhinoplasty at two different sites. The first patient suffered a CSF leak following septoplasty and presented to Alexandria University Hospital. The leak was still active at presentation and identified as coming from a defect in the roof of the sphenoid sinus and was repaired surgically. The second patient presented 4 days after her cosmetic septorhinoplasty with a CSF leak and significant pneumocephalus. She was managed conservatively. Understanding the anatomical variations of the paranasal sinuses and implementing proper surgical techniques are crucial in preventing intracranial complications when performing either septoplasty or septorhinoplasty. A good quality computed tomography of the nose and paranasal sinuses is a valuable investigation to avoid major complications especially CSF leaks following either procedure.

A Study on Insider Behavior Scoring System to Prevent Data Leaks

  • Lim, Young-Hwan;Hong, Jun-Suk;Kook, Kwang Ho;Park, Won-Hyung
    • Convergence Security Journal
    • /
    • v.15 no.5
    • /
    • pp.77-86
    • /
    • 2015
  • The organization shall minimize business risks associated with customer information leaks. Enhance information security activities through voluntary pre-check and must find a way to detect the personal information leakage caused by carelessness and neglect accident. Recently, many companies have introduced an information leakage prevention solution. However, there is a possibility of internal data leakage by the internal user who has permission to access the data. By this thread it is necessary to have the environment to analyze the habit and activity of the internal user. In this study, we use the SFI analytical technique that applies RFM model to evaluate the insider activity levels were carried out case studies is applied to the actual business.

Study on the applicability of the principal component analysis for detecting leaks in water pipe networks (상수관망의 누수감지를 위한 주성분 분석의 적용 가능성에 대한 연구)

  • Kim, Kimin;Park, Suwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.159-167
    • /
    • 2019
  • In this paper the potential of the principal component analysis(PCA) technique for the application of detecting leaks in water pipe networks was evaluated. For this purpose the PCA was conducted to evaluate the relevance of the calculated outliers of a PCA model utilizing the recorded pipe flows and the recorded pipe leak incidents of a case study water distribution system. The PCA technique was enhanced by applying the computational algorithms developed in this study which were designed to extract a partial set of flow data from the original 24 hour flow data so that the effective outlier detection rate was maximized. The relevance of the calculated outliers of a PCA model and the recorded pipe leak incidents was analyzed. The developed algorithm may be applied in determining further leak detection field work for water distribution blocks that have more than 70% of the effective outlier detection rate. However, the analysis suggested that further development on the algorithm is needed to enhance the applicability of the PCA in detecting leaks by considering series of leak reports happening in a relatively short period.

Prediction of Damages and Evacuation Strategies for Gas Leaks from Chlorine Transport Vehicles (염소 운송차량 가스누출시 피해예측 및 대피방안)

  • Yang, Yong-Ho;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.407-417
    • /
    • 2024
  • The objective of this study is to predict and reduce potential damage caused by chlorine gas leaks, a hazardous material, when vehicles transporting it overturn due to accidents or other incidents. The goal is to forecast the anticipated damages caused by chlorine toxicity levels (ppm) and to design effective response strategies for mitigating them. To predict potential damages, we conducted quantitative assessments using the ALOHA program to calculate the toxic effects (ppm) and damage distances resulting from chlorine leaks, taking into account potential negligence of drivers during transportation. The extent of damage from toxic gas leaks is influenced by various factors, including the amount of the leaked hazardous material and the meteorological conditions at the time of the leak. Therefore, a comprehensive analysis of damage distances was conducted by examining various scenarios that involved variations in the amount of leakage and weather conditions. Under intermediate conditions (leakage quantity: 5 tons, wind speed: 3 m/s, atmospheric stability: D), the estimated distance for exceeding the AEGL-2 level of 2 ppm was calculated to be 9 km. This concentration poses a high risk of respiratory disturbance and potential human casualties, comparable to the toxicity of hydrogen chloride. In particular, leaks in urban areas can lead to significant loss of life. In the event of a leakage incident, we proposed a plan to minimize damage by implementing appropriate response strategies based on the location and amount of the leak when an accident occurs.

Treatment of Prolonged Air-leak after Bilobectomy by Artificial Pneumoperitoneum (폐엽절제 후 발생한 지속적 공기누출의 인공기복에 의한 치료)

  • 조성준;이성호
    • Journal of Chest Surgery
    • /
    • v.35 no.12
    • /
    • pp.902-905
    • /
    • 2002
  • Pulmonary resection often leaves a pleural space problem that can cause prolonged air leaks. We describe a patient with lung cancer undergoing a right middle and lower lobectomy complicated by prolonged air leaks. He had a history of pulmonary tuberculosis and COPD. Artificial pneumoperitoneum was made by instillation of air via a small central vein catheter into the left lower quadrant on postoperative day(POD) 21. The air leak ceased on POD 23 and the chest tube was removed on POD 25.