Treatment of Prolonged Air-leak after Bilobectomy by Artificial Pneumoperitoneum  

조성준 (강원대학교병원 흉부외과)
이성호 (강원대학교병원 흉부외과)
Publication Information
Journal of Chest Surgery / v.35, no.12, 2002 , pp. 902-905 More about this Journal
Abstract
Pulmonary resection often leaves a pleural space problem that can cause prolonged air leaks. We describe a patient with lung cancer undergoing a right middle and lower lobectomy complicated by prolonged air leaks. He had a history of pulmonary tuberculosis and COPD. Artificial pneumoperitoneum was made by instillation of air via a small central vein catheter into the left lower quadrant on postoperative day(POD) 21. The air leak ceased on POD 23 and the chest tube was removed on POD 25.
Keywords