• Title/Summary/Keyword: Leakage water

Search Result 894, Processing Time 0.025 seconds

Geochemical Investigation of Fluoride Migration in the Soil Affected by an Accidental Hydrofluoric Acid Leakage (불산 누출사고 지역 토양수의 지구화학적 특성을 통한 불소 거동 및 확산 잠재성 연구)

  • Kwon, Eunhye;Lee, Hyun A;Kim, Doyoung;Lee, Junseok;Lee, Sanghoon;Yoon, Hye-On
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.3
    • /
    • pp.65-73
    • /
    • 2015
  • The hydrofluoric acid (HF) leakage accident occurred on September 2012 in Gumi, Korea affected the surrounding soils and plants. In this study, we investigated fluoride migration in Gumi area through geochemical properties of soil-liquid phase (pore water F and water-soluble F). The concentrations of porewater F and water-soluble F were obtained from N.D (Not detected) to 9.79 mg/L and from 0.001 to 21.4 mg/L, respectively. F in pore water seemed to be affected by artificial and natural origin, and PHREEQC results implied that fluorite is F control factor. F concentrations of soil and soil-liquid phase did not exceed concern level of regulatory criteria and showed similar trends compared by previous studies. Therefore, F contents remained in the soil and soil-liquid phase were considered to be not affected by HF leakage accident.

Development of new electrical leakage detection system for waste landfil (위생매립지 누출검지 및 누출위치 파악을 위한 전극배치시스템 개발)

  • Han, Sang-Jae;Shin, Hyun-Young;Jung, Jae-Hyun;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.242-250
    • /
    • 2008
  • Lining systems are used for two purpose in landfills : as covers to minimize leachate generation and surface water contamination by providing a barrier from precipitation and other percolating waters, and as containment liners to contain leachate and minimize its downward migration into underlying groundwater. So identifying leaks in landfill liners is an essential part of waste management. There are many leakage detection systems to monitor and seek leakage location, such as two electrode method, electrode grid method, diffusion hoses, capacitance sensors and tracers sensing cables. However, most of them can be applied in the new landfill construction sites because sensors must be installed prior to work. This paper presents a new type of leakage detection system, so called fence type electrode arrangement system, to monitor leakage and to seek leakage location in working landfill as well as new landfill. This system is based on the measurement of an electrical current flowing through leakage point. Series of laboratory tests are performed to investigate an availability of this system and this paper present some of these results.

  • PDF

A Study on Under-registration of 13mm Water Meters (가정용 13mm 수도계량기 미감지율 조사연구)

  • Ahn, Jae-Chan;Ha, Sung-Ho;Jeong, Pan-Sig;Choi, Jeong-Sub;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.506-514
    • /
    • 2005
  • Unaccounted-for water subtracting water sold from produced water includes leakage, under-registration, unauthorized use, etc. To improve accounted-for water ratio, firstly, it should be attempted to accurately identify where unaccounted-for water is, and then it must to be reduced. Under-registration of meter is caused by allowable tolerance of meter, improper size of meter installed, gradient installation, etc. Under-registered water of meters has ever been the second large amount of unaccounted-for water next to leakage, but still is not estimated exactly. In this study, the estimated value as under-registered water was obtained by using the selected-area modeling program. As a result, the under-registered water ratio of 13mm meters was approximately 1.23%. Those of meters according to ages 1, 3, and, 5 years old were 1.46% 2.77% and, 2.26%, respectively but that of 7 years old meters showed over-registration of 1.59%.

Application of Resistivity/SP Monitoring Technique to Maintenance of Water Utilization Facilities (수리시설물의 유지관리를 위한 비저항/SP 모니터링기법 연구)

  • Park, Sam-Gyu;Kim, Jung-Ho;Seo, Goo-Won;Won, Jong-Geun;Kim, Byung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.71-76
    • /
    • 2005
  • The subject of this paper is research into the application of resistivity/SP monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity/SP measurement, inclinometer, piezometer, and water gauge at an embankment, Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and SP variations that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variations of resistivity and SP at the embankment were provided from the monitoring data and we could accurately locate the portions of which resistivities and SP have sharply changed, Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity and SP, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity and SP data would be much more preferable to performing the just one-time measurements.

  • PDF

N-Type Carbon-Nanotube MOSFET Device Profile Optimization for Very Large Scale Integration

  • Sun, Yanan;Kursun, Volkan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.2
    • /
    • pp.43-50
    • /
    • 2011
  • Carbon-nanotube metal oxide semiconductor field effect transistor (CN-MOSFET) is a promising future device candidate. The electrical characteristics of 16 nm N-type CN-MOSFETs are explored in this paper. The optimum N-type CN-MOSFET device profiles with different number of tubes are identified for achieving the highest on-state to off-state current ratio ($I_{on}/I_{off}$). The influence of substrate voltage on device performance is also investigated in this paper. Tradeoffs between subthreshold leakage current and overall switch quality are evaluated with different substrate bias voltages. Technology development guidelines for achieving high-speed, low-leakage, area efficient, and manufacturable carbon nanotube integrated circuits are provided.

A Study on Phenomena of Watertree and Dielectric Breakdown in XLPE (XLPE의 수트리와 절연파괴 현상에 관한 연구)

  • Lee, Sung-Il;Ryu, Sung-Lim;Park, Il-Kyu;Lee, Ho-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.262-265
    • /
    • 2001
  • In order to investigate the water tree degradation behavior on XLPE cable, direct voltage of 200 to 800V has been applied to the material at $50^{\circ}C\sim100^{\circ}C$. and the water tree property has been correlated with voltage and temperature in this study. The leakage current was shown to increase as temperature increased and the Ohm's law was generally satisfied in this experiment though some experimental errors were found. The leakage current was shown to decrease and reach to the stable state with time. It was also shown that the time for the stabilization of leakage current was lessened as voltage increased

  • PDF

A Study on the Evaluation Method of Water Leakage Repair in Polyacrylic Resin (폴리 아크릴 레진의 누수 보수 평가에 관한 연구)

  • Cho, Il-Kyu;Kim, Keun-Hur;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.223-224
    • /
    • 2017
  • In this study, various materials such as epoxy material, urethane material, cement material, and acrylic material are used to solve the water leakage occurring in underground structures. However, in the reality that the durability is insufficient and the effect is insufficient, it is aimed to improve the repairing effect by using cement and acrylics in combination. As a first study, we tried to verify the performance of improve the performance by checking the product properties according to the composition ratio of polyacrylic resin. Polyacrylic resin is evaluated in three different composition ratios. When the material is selected for polyacrylic resin, it is applied to the field to understand the maintenance effect and durability.

  • PDF

A Study on Phenomena of Watertree and Dielectric Breakdown in XLPE (XLPE의 수트리와 절연파괴 현상에 관한 연구)

  • 이성일;류성림;박일규;이호식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.262-265
    • /
    • 2001
  • In order to investigate the water tree degradation behavior on XLPE cable, direct voltage of 200 to 800V has been applied to the material at 50$^{\circ}C$∼100$^{\circ}C$, and the water tree property has been correlated with voltage and temperature in this study. The leakage current was shown to increase as temperature increased and the Ohm's law was generally satisfied in this experiment though some experimental errors were found. The leakage current was shown to decrease and reach to the stable state with time. It was also shown that the time for the stabilization of leakage current was lessened as voltage increased

  • PDF

Standard Manual for Preventing and Maintaining Leakage of Underground Structures in Apartment Houses - Part 1. Maintenance Plan and Inspection - (공동주택 지하 구조물의 누수 예방 및 유지보수를 위한 표준 매뉴얼 - Part 1. 유지관리 계획 및 점검 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Lee, Sung Jin;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.237-238
    • /
    • 2019
  • As part of the development of building technology to improve the living performance closely related with lifestyle to Realize the Housing Welfare, the standard manual for the prevention and maintenance of water leaks in the underground structures of apartment buildings consists of Part 1 and Part 2. This study further covered the maintenance plan and inspection carried out in Part 1.

  • PDF

A Flashover Prediction Method by the Leakage Current Monitoring in the Contaminated Polymer Insulator (누설 전류 모니터링에 의한 오손된 고분자 애자에서의 섬락 예지 방법)

  • 박재준;송영철
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.7
    • /
    • pp.364-369
    • /
    • 2004
  • In this Paper, a flashover prediction method using the leakage current in the contaminated EPDM distribution polymer insulator is proposed. The leakage currents on the insulator were measured simultaneously with the different salt fog application such as 25g, 50g, and 75g per liter of deionized water. Then, the measured leakage currents were enveloped and transformed as the CDFS using the Hilbert transform and the level crossing rate, respectively. The obtained CDFS having different gradients(angles) were used as a important factor for the flashover prediction of the contaminated polymer insulator. Thus, the average angle change with an identical salt fog concentration was within a range of 20 degrees, and the average angle change among the different salt fog concentrations was 5 degrees. However, it is hard to be distinguished each other because the gradient differences among the CDFS were very small. So, the new weighting value was defined and used to solve this problem. Through simulation, it Is verified that the proposed method has the capability of the flashover prediction.