• Title/Summary/Keyword: Leakage volume

Search Result 218, Processing Time 0.031 seconds

Early Onset Subsequent Vertebral Compression Fracture after Percutaneous Verteroplasty (경피적 척추 성형술 후 조기에 발생한 새로운 척추 압박골절)

  • Kim, Jong-Kil;Choi, Byeong-Yeol;Park, Young-Chul;Kim, Dong-Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.24-29
    • /
    • 2019
  • Purpose: To evaluate the characteristics and the risk factors of early onset subsequent vertebral compression fractures after percutaneous vertebroplasty. Materials and Methods: A total of 44 patients, who had a new subsequent vertebral fracture after percutaneous vertebroplasty for an osteoporotic vertebral compression fracture between January 2013 and December 2015, were recruited. The patients were divided into two groups according to the onset period of subsequent fracture. The number of patients who had a fracture within 3 months following vertebroplasty were 22 cases (Group A); after 3 months were 22 cases (Group B). Variables, including age, sex, bone mineral density (BMD), body mass index (BMI), preexisting vertebral compression fracture, location of the initial fracture, intradiscal cement leakage, injected cement volume, restoration of vertebral body height, and correction of kyphosis, in the two groups were analyzed and compared retrospectively. Results: The age, sex, BMD, BMI, preexisting vertebral compression fracture, location of the initial fracture, intradiscal cement leakage, and correction of kyphosis were similar in the two groups. Both a greater volume of bone cement injected and a greater degree of vertebral height restoration contributed significantly to the risk of fracture within 3 months. Conclusion: The cement volume and degree of height restoration are risk factors for early onset fracture at the adjacent vertebrae after percutaneous vertebroplasty and close attention is needed during the follow-up period.

A Study on the Performence improvment of Contactless Inductive Coupler for the Stocker System (반도체 제조장비용 무접점 Inductive Coupler의 성능개선을 위한 연구)

  • Kim, Hyun-Woo;Ban, Sang-Ho;Kwon, Ho;Park, Jae-Bum;Lee, Ju;Lee, Chul-Jik;Kim, Suk-Tae;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.923-925
    • /
    • 2002
  • The existing contactless inductive coupler has many problems because of its large volume and high level of exciting current, so a new contactless inductive coupler is being required under the circumstances and the load requirement. For a contactless inductive coupler in the manufacturing equipment of semiconductor, the coupler's efficiency is low because of its small magnetic inductance and large leakage inductance. Moreover, the high frequency switching to increase energy density per unit volume increases the iron loss and the eddy current loss, so it must be considered deeply when selecting core materials. Therefore, this paper presents core materials and shape to improve the performance of the contactless inductive coupler according to the coil positions.

  • PDF

An Analytical Study on the Performance Analysis of a Unit-In-jector System of a Diesel Engine

  • Kim, Chul-Ho;Lee, Jong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.146-156
    • /
    • 2003
  • A numerical algorithm is developed to analyze the performance of a Unit-injector (UI) System for a diesel engine. The fundamental theory of the algorithm is based on the continuity equation of fluid dynamics. The loss factors that should be seriously regarded on the continuity equation are the compressibility effect of liquid fuel, the wall friction loss in high-pressure fuel lines of the system, the kinetic energy loss of fuel in the system, and the leakage of fuel out of the control volume. For an evaluation of the developed simulation algorithm, the calculation results are compared with the experimental outputs provided by the Technical Research Center of Doowon Precision Industry Co. (DPICO) ; the maximum pressure in the plunger chamber (P$\_$p/) and total amount of fuel injected into a cylinder per cycle (Q$\_$f/) at each operational condition. The result shows that the average error rate (%) of P$\_$p/ and Q$\_$f/ are 2.90% and 4.87%, respectively, in the specified operational conditions. Hence, it can be concluded that the analytical simulation algorithm developed in this study can be reasonably applied to the performance prediction of newly designed UI system.

Lip Type Electromagnetic Flap Valve for Low Leakage (누수 최소화를 위한 립 타입 전자력 플랩 밸브)

  • Lim, In-Ho;Lee, Ki-Jung;Sim, Woo-Young;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1476-1477
    • /
    • 2008
  • This paper reports on a flexible flap valve actuated by electromagnetic force under a constant pressure source. The flexible flap valve consists of the three main components: a flexible flap with a steel disk embedded in PDMS, an electromagnetic actuator and two glass plates with inlet and outlet. Sealing lip structures for improving the valve characteristics are added on the outlet of the bottom glass substrate. The flap valve is fabricated by the spin-coating process, the EDM process, SU-8 mold process and oxygen plasma treatment. The dimension of an assembled flap valve is $12mm{\times}20mm{\times}28mm$. The stroke volume of the flap valve is measured for various pressures and open times. When the input voltage of 30 V is applied for 0.33 s, the minimum stroke volume of the flap valve is 70 ${\mu}L$ at 50 kPa.

  • PDF

Optimal Design of A Quick-Acting Hydraulic Fuse Using Design of Experiments and Complex Method (실험계획법과 콤플렉스법에 의한 고성능 유압휴즈의 최적 설계)

  • Lee, Seong Rae
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.8-14
    • /
    • 2015
  • A quick-acting hydraulic fuse, which is mainly composed of a poppet, a seat, and a spring, must be designed to minimize the leaked oil volume during fuse operation on a line rupture. The optimal design parameters of a quick-acting hydraulic fuse were searched using the design of experiments method and the complex method. First, the $L_{50}(5^4)$ orthogonal array is used to find the robust minimum point among the 625 points of design variables. The search range can then be narrowed around the robust minimum point. Second, the $L_{25}(5^4)$ orthogonal array is used to obtain the variations of the design variables in the narrowed search range. The variations of design variables are used to set the structure of a polynomial equation representing the leakage oil volume of the quick-acting hydraulic fuse. The least squares method is then applied to obtain the coefficients of polynomial equation. Finally, the complex method is used to find the optimal design parameters where the objective function is described by the polynomial equation.

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

A Comparative Study of the Navier-Stokes Equation & the Reynolds Equation in Spool Valve Analysis (스풀밸브 해석에서 Navier-Stokes 방정식과 Reynolds 방정식에 의한 비교 연구)

  • Hong, Sung-Ho;Son, Sang-Ik;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.28 no.5
    • /
    • pp.218-232
    • /
    • 2012
  • In a spool valve analysis, the Reynolds equation is commonly used to investigate the lubrication characteristics. However, the validity of the Reynolds equation is questionable in a spool valve analysis because cavitation often occurs in the groove and the depth of the groove is much higher than the clearance in most cases. Therefore, the validity of the Reynolds equation in a spool valve analysis is investigated by comparing the results obtained from the Reynolds equation and the Navier-Stokes equation. Dimensionless parameters are determined from a nondimensional form of the governing equations. The differences between the lateral force, friction force, and volume flow rate (leakage) obtained by the Reynolds equation and those obtained by the Navier-Stokes equation are discussed. It is shown that there is little difference (less than 10%), except in the case of a spool valve with many grooves where no cavitation occurs in the grooves. In most cases, the Reynolds equation is effective for a spool valve analysis under a no cavitation condition.

Morphologic change of rectosigmoid colon using belly board and distended bladder protocol

  • Cho, Yeona;Chang, Jee Suk;Kim, Mi Sun;Lee, Jaehwan;Byun, Hwakyung;Kim, Nalee;Park, Sang Joon;Keum, Ki Chnag;Koom, Woong Sub
    • Radiation Oncology Journal
    • /
    • v.33 no.2
    • /
    • pp.134-141
    • /
    • 2015
  • Purpose: This study investigates morphologic change of the rectosigmoid colon using a belly board in prone position and distended bladder in patients with rectal cancer. We evaluate the possibility of excluding the proximal margin of anastomosis from the radiation field by straightening the rectosigmoid colon. Materials and Methods: Nineteen patients who received preoperative radiotherapy between 2006 and 2009 underwent simulation in a prone position (group A). These patients were compared to 19 patients treated using a belly board in prone position and a distended bladder protocol (group B). Rectosigmoid colon in the pelvic cavity was delineated on planning computed tomography (CT) images. A total dose of 45 Gy was planned for the whole pelvic field with superior margin of the sacral promontory. The volume and redundancy of rectosigmoid colon was assessed. Results: Patients in group B had straighter rectosigmoid colons than those in group A (no redundancy; group A vs. group B, 10% vs. 42%; p = 0.03). The volume of rectosigmoid colon in the radiation field was significantly larger in group A (56.7 vs. 49.1 mL; p = 0.009). In dose volume histogram analysis, the mean irradiated volume was lower in patients in group B (V45 27.2 vs. 18.2 mL; p = 0.004). In Pearson correlation coefficient analysis, the in-field volume of rectosigmoid colon was significantly correlated with the bladder volume (R = 0.86, p = 0.003). Conclusion: Use of a belly board and distended bladder protocol could contribute to exclusion of the proximal margin of anastomosis from the radiation field.

Intracavitary Radiation Therapy for Recurrent Cystic Brain Tumors with Holmium-166-Chico : A Pilot Study

  • Ha, Eun Jin;Gwak, Ho-Shin;Rhee, Chang Hun;Youn, Sang Min;Choi, Chang-Woon;Cheon, Gi Jeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.175-182
    • /
    • 2013
  • Objective : Intracavitary injection of beta-emitting radiation source for control of cystic tumors has been tried with a benefit of localized internal radiation. The authors treated cystic brain tumor patients with Holmium-166-chitosan complex (Ho-166-chico), composed of a beta-emitting radionuclide Holmium-166 and biodegradable chit polymer, and evaluated the safety and effective measurement for response. Methods : Twenty-two patients with recurrent cystic brain tumor and/or located in a deep or eloquent area were enrolled in this pilot study. The cyst volume and wall thickness were determined on CT or MRI to assess radiological response. The activity of Ho-166-chico injected via Ommaya reservoir was prescribed to be 10-25 Gy to the cyst wall in a depth of 4 mm. Results : There was neither complications related to systemic absorption nor leakage of Ho-166-chico in all 22 patients. But, two cases of oculomotor paresis were observed in patients with recurrent craniopharyngioma. Radiological response was seen in 14 of 20 available follow-up images (70%). Seven patients of 'evident' radiological response experienced more than 25% decrease of both cyst volume and wall thickness. Another 7 patients with 'suggestive' response showed decrease of cyst volume without definitive change of the wall thickness or vice versa. All patients with benign tumors or low grade gliomas experienced symptomatic improvement. Conclusion : Ho-166-chico intracavitary radiation therapy for cystic tumor is a safe method of palliation without serious complications. The determination of both minimal effective dosage and time interval of repeated injection through phase 1 trial could improve the results in the future.

Preliminary study on a 3D field permanent magnet flux switching machine - from tubular to rotary configurations

  • Wang, Can-Fei;Shen, Jian-Xin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.4
    • /
    • pp.505-508
    • /
    • 2012
  • A permanent magnet flux switching (PMFS) machine has a simple rotor, whilst both magnets and coils are set in the stator, resulting in easy removal of heat due to both copper loss and eddy current loss in magnets. However, the volume of magnets used in PMFS machines is usually larger than in conventional PM machines, and leakage flux does exist at the non-airgap side. To make full use of the magnets and gain higher power density, a novel 3-dimensional (3D) field PMFS machine is developed. It combines merits of the tubular linear machine, external-rotor rotary machine and axial-flux rotary machine, hence, offers high power density and peak torque capability, as well as efficient utility of magnets owing to the unique configuration of triple airgap fields.