• Title/Summary/Keyword: Leakage signal

Search Result 342, Processing Time 0.019 seconds

Acoustic Emission based early fault detection and diagnosis method for pipeline (음향방출 기반 배관 조기 결함 검출 및 진단 방법)

  • Kim, Jaeyoung;Jeong, Inkyu;Kim, Jongmyon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.3
    • /
    • pp.571-578
    • /
    • 2018
  • The deteriorated pipline often causes the unexpected leakage and crack. Negligence and late maintenance leads the enormous damage for gas and water resource. This paper proposes early fault detection and diagnosis algorithm for pipeline using acoustic emission (AE) signals. Early fault detection method for pipeline compares the frequency amplitude of the spectrum to that of the spectrum in normal condition. Larger amplitude of the spectrum indicates abnormal condition. Early fault diagnosis algorithm uses support vector machines (SVM), which is trained for normal and abnormal conditions to diagnose the measured AE signal from the target pipeline. In the experiment, a pipeline testbed is constructed similarly to real industrial pipeline. Normal, 5mm cracked, 10mm holed pipelines are installed and tested in this study. The proposed fault detection and diagnosis technique is validated as an efficient approach to detect early faulty condition of pipeline.

The electrical properties study with specific of phase transition of Lead Monoxide by PIB(Particle In Binder) (PIB(Particle In Binder) 방법으로 제조된 산화납의 특이상전이에 따른 전기적 특성 평가)

  • Kim, Sung-Hyun;Kim, Young-Bin;Jung, Suk-Hee;Kim, Min-Woo;Oh, Kyung-Min;Park, Ji-Gun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.19-25
    • /
    • 2008
  • Commercial analog x-ray detectors based on film cassettes have been showing problems such as with image storage and image transmission. Recently direct conversion material, photoconductor whit flat panel have been researched which generate the electron hole-pair (EHP). In this paper, we researched the electrical properties of the PbO and Lead(II) oxide PbO. film which fabricated by Particle-In-Binder(PIB) method. We compared tetragonal ${\alpha}$-PbO with orthorhombic ${\beta}$-PbO physical property. Tetragonal material was more than orthorhombic material in other paper. The solution was Poly Vinyl Butyral(PVB) in the PIB. We discussed about the sample of x-ray sensitivity, leakage current, Signal to Noise Rate and investigated SEM for the physical property of sample. We need to think more research ${\alpha}$-PbO material fabrication.

  • PDF

Wireless Water Leak Detection System Using Sensor Networks (센서네트워크를 이용한 무선 누수 탐지 시스템)

  • Choi, Soo-Hwan;Eom, Doo-Seop
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.125-131
    • /
    • 2011
  • Water leak detection system is a system based on wireless sensor networks(WSNs) which detect a leak on water supply, localize the leak position and finally inform a water management center. A traditional leak detection method is to use experienced personnel who walk along a pipeline listening to the sound that is generated by the leaks and their effectiveness depend on the experience of the user. Also making more successful detection, it should be processed at middle of the night when people do not use water, as the result users have to operate the leak detection system at midnight. In this paper, we propose a new method for the water leak detection system based on the WSNs and describe it in detail. Leak detection devices which detect a leakage of water transmit and receive the result of water leak detection with each other by configuring WSNs to improve reliability of the detection result. Also, we analyzed the sound from water flowed in pipeline, proposed the pre-signal processing to separate a leakage sound from noisy sound. And lastly, It is especially important to make a time synchronization with water leak detection devices that are installed on the pipeline, we used 1PPS(1 Pulse Per Second) signal generated by GPS, therefore we could get a precise time synchronization. The proposed system set up in Namyangju and performances were evaluated.

A Study of the Exclusive Embedded A/D Converter Using the Microprocessor and the Noise Decrease for the Magnetic Camera (마이크로프로세서를 이용한 자기카메라 전용 임베디드형 AD 변환기 및 잡음 감소에 관한 연구)

  • Lee, Jin-Yi;Hwang, Ji-Seong;Song, Ha-Ryong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.99-107
    • /
    • 2006
  • Magnetic nondestructive testing is very useful far detecting a crack on the surface or near of the surface of the ferromagnetic materials. The distribution of the magnetic flux leakage (DMFL) on a specimen has to be obtained quantitatively to evaluate the crack. The magnetic camera is proposed to obtain the DMFL at the large lift-off. The magnetic camera consists of a magnetic source, magnetic lens, analog to digital converters (ADCs), interface, and computer. The magnetic leakage fields or the distorted magnetic fields from the object, which are concentrated on the magnetic lens, are converted to analog electrical signals tv arrayed small magnetic sensors. These analog signals are converted to digital signals by the ADCs, and are stored, imaged, and processed by the interface and computer. However the magnetic camera has limitations with respect to converting and switching speed, full range and resolution, direct memory access (DMA), temporary storage speed and volume because common ADCs were used. Improved techniques, such as those that introduce the operational amplifier (OP-Amp), amplify the signal, reduce the connection line, and use the low pass filter (LPF) to increase the signal to noise ratio are necessary. This paper proposes the exclusive embedded ADC including OP-Amp, LPF, microprocessor and DMA circuit for the magnetic camera to satisfy the conditions mentioned above.

Design of Ku-Band Low Noise Amplifiers including Band Pass Filter Characteristics for Communication Satellite Transponders (대역통과여파기 특성을 갖는 통신위성중계기용 Ku-Band 저잡음증폭기의 설계 및 제작)

  • 임종식;김남태;박광량;김재명
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.5
    • /
    • pp.872-882
    • /
    • 1994
  • In this paper, the Low Noise Amplifier(LNA) is designed and fabricated to include a band pass filter characteristics considering the antenna system characteristics according to the transmitting and receiving signal level of communication satellite transponder. As an example, a 2-stage low noise amplifier and a 4-stage amplifier and designed, fabricated and measured at 14,0~14.5GHz of receiving frequency band. This fabricated LNA has shown the gain with very good flatness within pass-band, and its gain decreases rapidly out of band resulting in supperssion of the transmitting signal power leakage. It has shown the 20.3dB +- 0.1dB of pass-band gain, the 1.44dB +-0.04dB of noise figure and the 14dB rejection out of band(12.25~12.75GHz). The gain flatness, noise figure and group delay of this 2-stage LNA satisfactorily met the simulation results. And the fabricated 4-stage amplifier has shown the more than 42dB of pass-band gain, the +-0.25dB of flatness and the 28dB of the rejection effect for transmitting power leakage. The 2-stage LNA and 4-stage amplifier, in this paper, will bring a design margin for the input filter and also result in the system cost reduction.

  • PDF

Fabrication of IMT-2000 Linear Power Amplifier using Current Control Adaptation Method in Signal Cancelling Loop (신호 제거 궤환부의 전류 제어 적응형 알고리즘을 이용한 IMT-2000용 선형화 증폭기 제작)

  • 오인열;이창희;정기혁;조진용;라극한
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.1
    • /
    • pp.24-36
    • /
    • 2003
  • The digital mobile communication will be developed till getting multimedia service in anyone, any where, any time. Theses requiring items are going to be come true via IMT-2000 system. Transmitting signal bandwidth of IMT-2000 system is 3 times as large as IS-95 system. That is mean peak to average of signal is higher than IS-95A system. So we have to design it carefully not to effect in adjacent channel. HPA(High Power Amplifier) located in the end point of system is operated in 1-㏈ compression point(Pl㏈), then it generates 3rd and 5th inter modulation signals. Theses signals affect at adjacent channel and RF signal is distorted by compressed signal which is operated near by Pl㏈ point. Then the most important design factor is how we make HPA having high linearity. Feedback, Pre-distorter and Feed-forward methods are presented to solve theses problems. Feed-forward of these methods is having excellent improving capacity, but composed with complex structure. Generally, Linearity and Efficiency in power amplifier operate in the contrary, then it is difficult for us to find optimal operating point. In this paper we applied algorithm which searches optimal point of linear characteristics, which is key in Power Amplifier, using minimum current point of error amplifier in 1st loop. And we made 2nd loop compose with new structure. We confirmed fabricated LPA is operated by having high linearity and minimum current condition with ACPR of -26 ㏈m max. @ 30㎑ BW in 3.515㎒ and ACLR of 48 ㏈c max@${\pm}$㎒ from 1W to 40W.

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.

Radiation detector material development with multi-layer by hetero-junction for the reduction of leakage current (헤테르접합을 이용한 누설전류 저감을 위한 다층구조의 방사선 검출 물질 개발)

  • Oh, Kyung-Min;Yoon, Min-Seok;Kim, Min-Woo;Cho, Sung-Ho;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.11-15
    • /
    • 2009
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using a multi-layer technique to decrease dark current. High efficiency materials in substitution for Amorphous Selenium(a-Se) have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using PN junction or Hetero junction already used as solar cell, semiconductor. Particle-In -Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in Particle-In -Binder method. To make up for the weak points, multi-layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity, signal linearity is measured to evaluate multi-layer radiation sensor material.

  • PDF

Applicability of the Multi-Channel Surface-soil CO2-concentration Monitoring (SCM) System as a Surface Soil CO2 Monitoring Tool (다채널 지표토양 CO2 농도 모니터링(SCM) 시스템 개발 및 적용성 평가 연구)

  • Sung, Ki-Sung;Yu, Soonyoung;Choi, Byoung-Young;Park, Jinyoung;Han, Raehee;Kim, Jeong-Chan;Park, Kwon Gyu;Chae, Gitak
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.1
    • /
    • pp.41-55
    • /
    • 2015
  • Monitoring of $CO_2$ release through the ground surface is essential to confirm the safety of carbon storage projects. We conducted a feasibility study of the multi-channel surface-soil $CO_2$-concentration monitoring (SCM) system as a soil $CO_2$ monitoring tool with a small scale injection test. The background concentrations showed the distinct diurnal variation. The negative relation of $CO_2$ with temperature and the low $CO_2$ concentrations during the day imply that surface-soil $CO_2$ depends on photosynthesis and respiration. After 4.2 kg of $CO_2$ injection (1 m depth for 29 minutes), surface-soil $CO_2$ concentrations increased in the all five chambers, which were located less than 2.8 m of distance from each other. The $CO_2$ concentrations seem to be recovered to the background around 4 hours after the injection ended. To determine the leakage, the data from Chamber 2 and 5 with low increase rates were used for statistical analyses. Coefficient of variation for 30 minutes ($CV_{30min}$.) is efficient to determine a leakage signal, with reflecting the fast change in $CO_2$ concentrations. Consequently, SCM and $CV_{30min}$ could be applied for an efficient monitoring tool to detect $CO_2$ release through the ground surface. Also, this study provides ideas for establishing action steps after leakage detection.