• 제목/요약/키워드: Leakage flow

검색결과 783건 처리시간 0.032초

재생펌프의 누설 유동 및 내부 유동에 관한 연구 (Study on the Leakage Flow and the Flow Analysis of Regenerative Pump)

  • 심창열;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.593-596
    • /
    • 2002
  • Flows in a regenerative pump were calculated for several flow-rates, using the CFX-Tascflow. The calculated results show the vortex structure in the impeller and side channel. The predicted performance shows considerable discrepancy form the measured values for low flow rates. Main source of the difference is the leakage flow of pump strongly affecting the performance of pump. A simple correlation was proposed using calculated leakage flows through the parametric calculations of the simplified passage.

  • PDF

축류홴 익단누설와류의 수치적 해석 (Numerical Analysis of a Tip Leakage Vortex in an Axial Flow Fan)

  • 장춘만;김광용
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.36-44
    • /
    • 2004
  • Three-dimensional vortical flow and separated flow topology near the casing wall in an axial flow fan having two different tip clearances have been investigated by a Reynolds-averaged Navier-Stokes (RANS) flow simulation. The simulation shows that the tip leakage vortex formed close to the leading edge of the blade tip on suction side grows in the streamwise direction. On the casing wall, a separation line is formed upstream of the leakage vortex center due to the interference between the leakage vortex and main flow. The reverse flow is observed between the separation line and the attachment line generated downstream of the trailing edge, and increased with enlarging tip clearance. The patterns of a leakage velocity vector including a leakage flow rate are also analyzed according to two tip clearances. It is noted that the understanding of the distribution of a limiting streamline on the casing wall is very important to grasp the characteristics of the vortical flow in the axial flow fan.

슈라우드 임펠러에서 누설 유동이 압축기 성능에 미치는 영향에 대한 수치해석적 연구 (Numerical Prediction of a Performance Change in a Compressor Shrouded Impeller with Cavity Leakage Flow)

  • 최민욱;주원구;박준영;윤의수;최상규
    • 한국유체기계학회 논문집
    • /
    • 제15권3호
    • /
    • pp.64-69
    • /
    • 2012
  • Generally the Shrouded type impeller is considered to free from the loss of tip leakage flow, but it is actually not possible to complete sealing between the rotating impeller and the sealing which is stay still. As a result, there is the possibility of flow leaking between impeller exit to entrance, especially with high pressure ratio compressor machine. The Cavity leakage flow is expected to influence negative effect on a machine performance and also inner flow structure. In this study, Impeller with shroud-casing gap leakage flow is simulated by numerical method (Using CFX 12.1). The influence of leakage flow on compressor performance and efficiency will be analysed, also detail flowfield change will posted.

수치계산에 의한 축류터보기계의 유동장과 유동온실의 평가 III [회전차 익말단의 누설손실과 효율저하에 대한 평가] (Evaluation of Flowfield and Flow Losses insied Axial Turbomachinery Using Numerical Calculation [Evaluation of Tip Leakage Loss and Reduction of Efficiency by Tip Clearance])

  • 노수혁;조강래
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.240-247
    • /
    • 1998
  • Leakage vortices formed near blade tip causes an increase of total pressure loss near casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of tip clearance. In this study, the three-dimensional flowfields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and attack angle on the leakage vortex and overall performance, and the less distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss by tip clearance were evaluated using numerical results and aprroximate equations were presented to evaluate the reduction of rotor efficiency by tip leakage flow.

  • PDF

재생형 블로워의 누설유동 특성과 누설유량 저감을 통한 성능 향상 (Characteristics of Leakage Flow on Regenerative Blower and Leakage-reducing Design for Performance Enhancement)

  • 최민호;김영훈;강신형
    • 한국유체기계학회 논문집
    • /
    • 제14권4호
    • /
    • pp.57-63
    • /
    • 2011
  • Regenerative blower is suitable for hydrogen recirculation in fuel cell vehicle due to its capability of high pressure rise in single stage. Numerical models were applied to investigate inner gap leakage flow characteristics. A leakage flow in the inner gap is dominantly affected by pressure gradient. Therefore a blower with concentric channel type was suggested as one of modified models for reducing the inner gap pressure gradient. Also numerical results such as pressure rise, efficiency, leakage flow rate and torque were compared between modified and reference models. The performance of concentric channel type was improved as a result of reduced leakage flow.

수중펌프의 Leakage-free 자동탈착장치 개발 (Development of Leakage-free Automatic Discharge Connect in a Submersible Pump.)

  • 최영석;이경용;이창한;이종훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.63-68
    • /
    • 2002
  • ADC(Automatic Discharge Connector) is commonly used for the easy maintenance of the submersible pumps. However, the small gap between the flange of the base plate and that of the pipe due to the head rise, the flow momentum change and the mis-installation makes leakage flow that may be a great loss to the pumping system. In this study, the performance degradation was predicted with the simple leakage flow model through the gap. The newly developed ADC was tested and the leakage performance was compared with the old one and also no-leakage piping system. The newly developed ADC reduced the leakage flow in a satisfactory way in comparison with the old model.

  • PDF

수중펌프의 Leakage-free 자동탈착장치 개발 (Development of Leakage-free Automatic Discharge Connector in a Submersible Pump.)

  • 최영석;이경용;이창한;이종훈
    • 한국유체기계학회 논문집
    • /
    • 제6권2호
    • /
    • pp.23-28
    • /
    • 2003
  • ADC (Automatic Discharge Connector) is commonly used for the easy maintenance of the submersible pumps. However, the small gap between the flange of the base plate and that of the pipe due to the head rise, the flow momentum change and the mis-installation make a leakage flow that may be a great loss to the pumping system. In this study, the performance degradation was predicted with the simple leakage flow model through the gap. The newly developed ADC was tested, and the leakage performance was compared with the old one and also no-leakage piping system. The newly developed ADC reduced the leakage flow in a satisfactory way in comparison with the old model.

유량에 따른 축류홴의 익단누설와류 특성 (Flow Characteristics of a Tip Leakage Vortex at Different Flow Rates in an Axial Flow Fan)

  • 장춘만;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1383-1388
    • /
    • 2004
  • The flow characteristics in the blade passage of a low speed axial flow fan have been investigated by experimental analysis using a rotating hot-wire sensor for design and off-design operating conditions. The results show that the tip leakage vortex is moved upstream when flow rate is decreased, thus disturbing the formation of wake flow near the rotor tip. The tip leakage vortex interfaces with blade pressure surface, and results in high velocity fluctuation near the pressure surface. From the relative velocity distributions near the rotor tip, large axial velocity decay is observed at near stall condition, which results in large blockage compared to that at the design condition. Througout the flow measurements using a quasi-orthogonal measuring points to the tip leakage vortex, it is noted that the radial position of the tip leakage vortex is distributed between 94 and 96 percent span for all flow conditions. High spectrum density due to the large fluctuation of the tip leakage vortex is observed near the blade suction surface below the frequency of 1000 Hz at near stall condition.

  • PDF

축류형 유체 기계에서 팁 누설 유동 해석을 위한 난류 모델 성능 비교 (Performance Assessment of Turbulence Models for the Prediction of Tip Leakage Flow in an Axial-flow Turbomachinery)

  • 이공희;백제현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2162-2167
    • /
    • 2003
  • It is well-known that high anisotropic characteristic of turbulent flow field is dominant inside tip leakage vortex. This anisotropic nature of turbulence invalidates the use of the conventional isotropic eddy viscosity turbulence model based on the Boussinesq assumption. In this study, to check whether an anisotropic turbulence model is superior to the isotropic ones or not, the results obtained from steady-state Reynolds averaged Navier-Stokes simulations based on the RNG ${\kappa}-{\varepsilon}$ and the Reynolds stress model in two test cases, such as a linear compressor cascade and a forward-swept axial-flow fan, are compared with experimental data. Through the comparative study of turbulence models, it is clearly shown that the Reynolds stress model, which can express the production term and body-force term induced by system rotation without any modeling, should be used to predict the complex tip leakage flow, including the locus of tip leakage vortex center, quantitatively.

  • PDF

축류팬 익단누설와류의 비정상 특성 (Unsteady Nature of a Tip Leakage Vortex in an Axial Flow Fan)

  • 장춘만;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.845-850
    • /
    • 2003
  • Unsteady nature of a tip leakage vortex in an axial flow fan operating at a design and off-design operating conditions has been investigated by measuring the velocity fluctuation in a blade passage with a rotating hotwire probe sensor. Two hot-wire probe sensors rotating with the fan rotor were also introduced to obtain the cross-correlation coefficient between the two sensors located in the vortical flow as well as the fluctuating velocity. The results show that the vortical flow structure near the rotor tip can be clearly observed at the quasi-orthogonal planes to a tip leakage vortex. The leakage vortex is enlarged as the flow rate is decreased, thus resulting in the high blockage to main flow. The spectral peaks due to the fluctuating velocity near the rotor tip are mainly observed in the reverse flow region at higher flow rates than the peak pressure operating condition. However, no peak frequency presents near the rotor tip for near stall condition.

  • PDF