• 제목/요약/키워드: Leakage energy

검색결과 727건 처리시간 0.021초

초절전형 Schottky barrier rectifier의 제조 및 그 특성 (Fabrication and Characteristics of ultra power-saving Schottky barrier rectifier)

  • 김준식;최영호;박근영;최시영
    • 대한전자공학회논문지SD
    • /
    • 제39권4호
    • /
    • pp.35-40
    • /
    • 2002
  • 일함수가 낮은 바나듐과 몰리브덴을 장벽금속으로 사용하여 초절전형 SBR을 제조하였다. 일함수가 낮은 장벽금속을 사용함으로서 나타나는 역방향 누설전류를 감소시키기 위해 n-Si층에 아르곤 이온을 1×10/sup 14/ ion/㎠, 40 keV로 주입하였다. 제조된 소자의 전기적 특성은 60 A/㎠의 동일한 전류밀도에서 Mo-SBR의 V/sub F/는 0.39 V이고 V-SBR은 0.25 V로서 매우 낮은 V/sub F/를 나타내었다. 이에 따라 아르곤 이온주입에 의해 제조된 Y-SBR의 역방향 누설전류는 일반적인 V-SBR과 비교하여 20㎂ 이상 감소됨을 확인할 수 있었다. 또한, 아르곤 이온주입으로 인한 소자의 특성저하는 나타나지 않았다.

$Y_2O_3$ 첨가에 따른 ZnO:Pr 바리스터의 미세구조 및 전기적 특성에 관한 연구 (A Study on the Microstructure and Electrical Properties of ZnO:Pr Varistor with $Y_2O_3$Additive)

  • 남춘우;정순철;이외천
    • 한국전기전자재료학회논문지
    • /
    • 제11권1호
    • /
    • pp.48-56
    • /
    • 1998
  • Pr\ulcornerO\ulcorner-based ZnO varistors were fabricated in the range of $Y_2$O$_3$additive content from 0.5 to 4.0mol%, and its microstructure and electrical properties were investigated. Yttrium was distributed nearly in the grain boundaries and the cluster phase formed at nodal point but more in cluster phase. The average grain size was decreased markedly from 34.9 to 8.6${\mu}{\textrm}{m}$ with increasing $Y_2$O$_3$additive content. It is believed that the decrease of grain size is attributed to the formation of cluster phase and the weakening of driving force for liquid sintering. As a result, $Y_2$O$_3$was acted as the inhibitor of the grain growth. With increasing $Y_2$O$_3$additive content, the varistor voltage, the activation energy, and the nonlinear exponent increased whereas the leakage current decreased, especially 4.0mol% $Y_2$O$_3$-added varistor exhibited very good I-V characteristics; nonlinear exponent 87.42 and leakage current 46.77nA. On the other hand, as $Y_2$O$_3$additive content increases, the varistor showed tendency of the salient decrease for donor concentration and the increase for barrier height. Conclusively, it is estimated that ZnO:Pr varistor compositions added more than 2.0mol% $Y_2$O$_3$are to be used to fabricate useful varistors.

  • PDF

플라즈마 표면 처리를 이용한 TiO2 MOS 커패시터의 특성 개선 (Improvement in Capacitor Characteristics of Titanium Dioxide Film with Surface Plasma Treatment)

  • 신동혁;조혜림;박세란;오훈정;고대홍
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.32-37
    • /
    • 2019
  • Titanium dioxide ($TiO_2$) is a promising dielectric material in the semiconductor industry for its high dielectric constant. However, for utilization on Si substrate, $TiO_2$ film meets with a difficulty due to the large leakage currents caused by its small conduction band energy offset from Si substrate. In this study, we propose an in-situ plasma oxidation process in plasma-enhanced atomic layer deposition (PE-ALD) system to form an oxide barrier layer which can reduce the leakage currents from Si substrate to $TiO_2$ film. $TiO_2$ film depositions were followed by the plasma oxidation process using tetrakis(dimethylamino)titanium (TDMAT) as a Ti precursor. In our result, $SiO_2$ layer was successfully introduced by the plasma oxidation process and was used as a barrier layer between the Si substrate and $TiO_2$ film. Metal-oxide-semiconductor ($TiN/TiO_2/P-type$ Si substrate) capacitor with plasma oxidation barrier layer showed improved C-V and I-V characteristics compared to that without the plasma oxidation barrier layer.

지역난방 첨두부하보일러 대류부 부식 파손 분석 (Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler)

  • 김영수;채호병;홍민기;송민지;조정민;김우철;하태백;이수열
    • Corrosion Science and Technology
    • /
    • 제18권2호
    • /
    • pp.55-60
    • /
    • 2019
  • Corrosion failure in the convection part of peak load boiler (PLB) of the district heating system led to water leakage. Herein, Internal Rotary Inspection System (IRIS) inspection was employed to examine wall thinning and the cause of leakage in the flue tube. The corrosive products of the turbulator and tube were investigated using scanning electron microscope combined with energy dispersive spectroscopy, X-ray diffraction, and inductively coupled plasma (ICP). Majority of the serious corrosion damage was observed near the turbulator located in the upper flue tube. ICP analysis of the boiler water revealed oxide formation of sodium chloride in the lower end part of the flue tube. A cross-sectional view of the turbulator revealed the presence of double-layers of the oxide film, indicating environmental change during operation associated with water leakage. The outer surface of the turbulator consisted of the acid oxides such as $NO_x$ and $SO_x$ along with sodium and chloride ions. Dew-point corrosion is hypothesized as the main cause for the formation of acid oxides in the region of contact of the flue tube and the turbulator.

변형각의 측정 위치에 따른 6인치 탄소강관엘보의 파괴 기준 (Failure Criteria of a 6-Inch Carbon Steel Pipe Elbow According to Deformation Angle Measurement Positions)

  • 윤다운;전법규;장성진;박동욱;김성완
    • 한국지진공학회논문집
    • /
    • 제26권1호
    • /
    • pp.13-22
    • /
    • 2022
  • This study proposes a low-cycle fatigue life derived from measurement points on pipe elbows, which are components that are vulnerable to seismic load in the interface piping systems of nuclear power plants that use seismic isolation systems. In order to quantitatively define limit states regarding leakage, i.e., actual failure caused by low-cycle fatigue, in-plane cyclic loading tests were performed using a sine wave of constant amplitude. The test specimens consisted of SCH40 6-inch carbon steel pipe elbows and straight pipes, and an image processing method was used to measure the nonlinear behavior of the test specimens. The leakage lines caused by low-cycle fatigue and the low-cycle fatigue curves were compared and analyzed using the relationship between the relative deformation angles, which were measured based on each of the measurement points on the straight pipe, and the moment, which was measured at the center of the pipe elbow. Damage indices based on the combination of ductility and dissipation energy at each measurement point were used to quantitatively express the time at which leakage occurs due to through-wall cracking in the pipe elbow.

Consequence Analysis를 통한 도시가스 사고 피해 예측에 관한 연구 (A Study on the Prediction of City Gas Accident Damage by Consequence Analysis)

  • 안정식;김지혜;유지훈;김종경;강수비;조동현
    • 한국가스학회지
    • /
    • 제26권4호
    • /
    • pp.36-40
    • /
    • 2022
  • 최근 산업계에서 가장 큰 화두는 산업안전보건관리에 대한 영역이다. 도시가스는 인화성 가스로 화재 및 폭발의 위험이 크기 때문에 중대 산업 및 시민 재해를 예방하기 위해 많은 노력이 요구된다. 본 연구에서는 도시가스 안전관리의 일환으로 Consequence Analysis를 통해 도시가스 누출에 의한 폭발사고 발생 시 피해 범위 및 정도를 정량적으로 예측하고자 하였다. 그 결과 압력, 기상상황 등 다양한 누출조건에 따라 분석결과 값에 차이를 보였다. 본 연구를 통해 도시가스 안전관리업무 수행 시 도시가스 누출에 의한 사고의 시나리오를 마련하여 보다 효과적인 사고예방과 비상조치계획을 마련하는데 활용할 예정이다.

저가형 대기전력 차단장치 개발 (Development of a Low-Price Device for Standby Power Cut-off)

  • 이상윤
    • 융합신호처리학회논문지
    • /
    • 제16권3호
    • /
    • pp.115-121
    • /
    • 2015
  • 가정 및 사무실의 전기/전자 기기가 내부 혹은 외부로부터 주 기능 수행을 위한 명령을 기다리고 있는 상태에서 소모되는 대기전력을 차단할 수 있는 장치를 저가로 개발하였다. 대기전력을 줄이기 위한 노력이 선진국들뿐만 아니라 국제적 차원에서 경주되고 있다. 우리나라도 가구당 전자/전기기기 보유대수가 증가되는 추세에 따른 대기전력이 점차 증가하고 있어 전기 에너지 낭비의 큰 요인이 되고 있다. 기존의 대기전력 차단장치는 그 장치 자체의 소비전력이 크고, 구조가 복잡하여 사용 의미를 퇴색시키는 문제점을 안고 있다. 본 논문에서는 기존 제품의 이러한 문제점을 보완시키고 대기전력을 완전히 차단하는 저가형 대기전력 차단장치를 제안한다. 그리고 제안한 대기전력 차단장치를 누전차단기와 콘센트에 적용하여 회로를 설계 및 구현하고 실험을 통하여 그 우수성을 확인하였다.

PLT(5) 박막의 Switching 및 Retention 특성에 관한 연구 (A Study on the Switching and Retention Characteristics of PLT(5) Thin Films)

  • 최준영;장동훈;강성준;윤영섭
    • 대한전자공학회논문지SD
    • /
    • 제42권1호
    • /
    • pp.1-8
    • /
    • 2005
  • Sol-gel 법을 이용하여 Pt/TiO/sub x/SiO₂/Si 기판 위에 3.14×10/sup -4/㎠ 의 상부전극 면적을 갖는 PLT(5) 박막을 제작하여 스위칭 및 retention 특성에 대해 연구하였다. 4V 에서 3.56×10/sup -7/A/㎠의 누설전류밀도 값을 갖는 우수한 PLT(5) 박막에 펄스전압을 2V 에서 5V 까지 인가하였다. 펄스전압 증가에 따라 스위칭 시간은 0.52㎲ 에서부터 0.14㎲ 까지 감소하는 경향을 나타냈으며, 부하저항을 50Ω 에서 3.3Ω 으로 증가시킴에 따라 스위칭 시간이 0.14㎲에서 13.7㎲ 로 증가하는 것이 관찰되었다. 인가된 펄스 전압에 대한 스위칭 시간의 관계로부터 구한 활성화 에너지(Ea) 는 135kV/cm 이었다. PLT(5) 박막의 이력곡선과 분극 스위칭 실험으로부터 구한 switched charge density 사이의 오차는 약 10% 정도로 비교적 잘 일치하였으며, retention 특성은 105s 이후에도 약 8% 정도의 우수한 분극 감소 특성을 나타내었다.

압력구배가 없는 수중 파이프에서의 액체 오염물 유출에 관한 수치연구 (A Numerical Study on the Leakage of a Liquid from an Underwater Pipe without Pressure Gradient)

  • 송무석;한재훈
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제3권2호
    • /
    • pp.18-24
    • /
    • 2000
  • 성질이 다른 두가지 유체가 복잡한 상호작용을 하는 경우의 유동을 살펴 보기 위하여 2차원 비점성 수치해법을 개발하고, 이를 감압된 수중 파이프에서의 기름 유출 문제에 적용하였다. 두 유체의 경계면은 보오텍스 쉬트로 모델링하고 보오텍스격자법 (vortex-in-cell method)을 적용하여 유동을 해석하며, 장시간의 유동 모사를 위하여 경계면의 분할과 접합이 가능하도록 하였다. Boussinesq 가정에서 외부유체의 관내로의 유입 속도가 기존의 수학모델과 거의 동일함을 확인하였고, 경계면에서의 복잡한 상호 유입과 보오텍스 유동에도 불구하고 Lock Exchange가 발생함을 보였다. 개발된 수치해법은 다양한 해양환경의 2상유체 문제에 효과적으로 이용될 수 있다고 사료된다.

  • PDF

지하철에 의한 서울특별시 광역 지하수 유동 특성 (Regional Groundwater Flow Characteristics due to the Subway System in Seoul, Korea)

  • 신에스더;김형수;하규철;윤희성;이은희
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권3호
    • /
    • pp.41-50
    • /
    • 2015
  • Hydrogeologic environment of the Mega City such as Seoul, suffers from rapid changes caused by urbanization, construction of underground subway or buildings, and contaminant loading by diverse anthropogenic activities. Understanding the present condition of groundwater environment and water budget is necessary to prevent natural and manmade disasters and to prepare for sustainable water resource management of urban environment. In this study, regional groundwater flow and water budget status of Seoul was analyzed using numerical simulation. Modeling result indicated that groundwater level distribution of Seoul generally followed the topography, but the significant decreases in groundwater level were observed around the subway network. Steady-state water balance analysis showed groundwater recharge by rainfall and leakage from the water supply network was about 550,495 m3/day. Surface water inflow and baseflow rate via Han River and major streams accounted for 799,689 m3/day and 1,103,906 m3/day, respectively. Groundwater usage was 60,945 m3/day, and the total groundwater leakage along the subway lines amounted to 114,746 m3/day. Modeling results revealed that the subway could decrease net groundwater baseflow by 40%. Our study result demonstrated that the subway system can have a significant influence on the groundwater environment of Seoul.