• 제목/요약/키워드: Leakage current control system

검색결과 94건 처리시간 0.022초

고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터 (Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise)

  • 이성호;권정민;권봉환
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.

PSCAD/EMTDC를 이용한 ESS의 누설전류 모델링에 관한 연구 (A Study on Modeling of Leakage Current in ESS Using PSCAD/EMTDC)

  • 김지명;태동현;이일무;임건표;노대석
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.810-818
    • /
    • 2021
  • ESS의 누설전류는 PCS(Power Control System)측 누설전류와 계통불평형 전류로 인한 누설전류로 구분되는데, PCS측의 누설전류는 정상 상태 운전 시, IGBT(Insulated Gate Bipolar Transistor) 스위칭의 전압 변화량과 IGBT와 방열판 사이에 존재하는 기생 커패시턴스에 의해 발생한다. 또한, 계통불평형 전류에 의한 누설전류는 불평형 부하로 인해 발생한 불평형 전류가 Yg-∆ 결선방식의 3각 철심이 적용된 태양광전원 연계형 변압기의 중성선을 통해 ESS로 유입된다. 따라서, 본 논문에서는 방열판 유도공식을 통해 산정한 기생 커패시턴스에 의하여 PCS측의 누설전류 발생 메커니즘을 제시하고 또한, 계통불평형에 의한 ESS측의 누설전류 발생 메커니즘을 제안한다. 이를 바탕으로, 배전계통 상용해석 프로그램인 PSCAD/EMTDC를 이용하여 배터리부, PCS부, AC전원부로 이루어진 PCS측의 누설전류 발생 메커니즘과 배전 계통부, 불평형 부하부, ESS부로 이루어진 계통불평형에 의한 ESS측의 누설전류 발생 메커니즘을 모델링하고, 누설전류의 특성을 평가한다. 상기의 모델링을 바탕으로 시뮬레이션을 수행한 결과, 외함의 저항과 접지저항의 크기에 따라 PCS측의 누설전류는 7[mA]에서 34[mA]로, 계통불평형에 의한 배터리 외함으로 흐르는 누설전류는 3.96[mA]에서 10.76[mA]로 증가하여 배터리측에 큰 영향을 미침을 알 수 있었다.

지능형 콘센트를 위한 안드로이드 어플리케이션 개발 (The Development of Android Application for Intelligent Concent)

  • 한영오;김동우
    • 한국전자통신학회논문지
    • /
    • 제8권10호
    • /
    • pp.1515-1521
    • /
    • 2013
  • 본 논문에서는 저항성 누설전류, 과전류, 대기전력 차단기능을 갖는 지능형 콘센트와 연동하는 안드로이드 운영체제의 전력관리 어플리케이션을 개발한다. 개발된 전력관리 어플리케이션을 이용하면 언제, 어디서나 콘센트에서 발생될 수 있는 누전으로 인한 전기화재 및 감전 등을 모니터링하고, 콘센트에 공급되는 전력을 제어하여 실내의 가전기기에 대한 ON/OFF 제어 및 낭비되고 있는 대기전력을 손쉽게 차단할 수 있도록 하였다.

공간전압벡터 PWM을 이용한 컨버터/인버터 시스템에서의 커먼 모드 전압 펄스 제거 (Elimination of a Common Mode Voltage Pulse in Converter/Inverter System Modifying Space-Vector PWM Method)

  • 이현동;이영민;설승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권2호
    • /
    • pp.89-96
    • /
    • 1999
  • This paper proposes a common-mode voltage reduction method base on SVPWM(Space-Vector Pulsewidth Modulation) in three phase PWM converter/inverter system. By shifting the active voltage vector of inverter and aligning this to the active vector of converter, it is possible to eliminate a common-mode voltage pulse in one control period. Since the proposed PWM method maintains the active voltage vector, it does not affect the control performance of PWM converter/inverter system. Without any extra hardware, overall common mode voltage dv/dt and conrresponding leakage current can be reduced to two-third of the conventional three phase symmetric SVPWM scheme.

  • PDF

결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구 (A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

Analysis of Key Parameters for Inductively Coupled Power Transfer Systems Realized by Detuning Factor in Synchronous Generators

  • Liu, Jinfeng;Li, Kun;Jin, Ningzhi;Iu, Herbert Ho-Ching
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1087-1098
    • /
    • 2019
  • In this paper, a detuning factor (DeFac) method is proposed to design the key parameters for optimizing the transfer power and efficiency of an Inductively Coupled Power Transfer (ICPT) system with primary-secondary side compensation. Depending on the robustness of the system, the DeFac method can guarantee the stability of the transfer power and efficiency of an ICPT system within a certain range of resistive-capacitive or resistive-inductive loads. A MATLAB-Simulink model of a ICPT system was built to assess the system's main evaluation criteria, namely its maximum power ratio (PR) and efficiency, in terms of different approaches. In addition, a magnetic field simulation model was built using Ansoft to specify the leakage flux and current density. Simulation results show that both the maximum PR and efficiency of the ICPT system can reach almost 70% despite the severe detuning imposed by the DeFac method. The system also exhibited low levels of leakage flux and a high current density. Experimental results confirmed the validity and feasibility of an ICPT system using DeFac-designed parameters.

누설변압기가 부착된 전원 불평형 3상 전압형 PWM 컨버터 운전법 (Operating Method of 3 Phase Voltage type PWM Converter for Unbalanced Voltage with Leakage Transformer)

  • 전지용;김영춘;조유환;이근홍
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.125-127
    • /
    • 2005
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining way of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. Because it is possible that the unbalanced System control is used to leakage transformer not equaled reactance by each phase in rectifier system, the proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

  • PDF

중소기업 산업기술 유출방지를 위한 정보보호 관리체계 설계 (The Design of Information Security Management System for SMEs Industry Technique Leakage Prevention)

  • 장항배
    • 한국멀티미디어학회논문지
    • /
    • 제13권1호
    • /
    • pp.111-121
    • /
    • 2010
  • 중소기업들은 산업기술 유출방지에 필요성을 인식하여 많은 예산을 들여 정보보호 시스템을 구축하고 있으나, 정보보호 전담조직을 구성하여 통합적인 정보보호 관리체계에 따라 일관성 있는 정보보호 시스템을 구축하지 못하고 특정시스템의 단발성 도입이 이루어지고 있다. 본 연구에서는 중소기업 산업기술 유출현황 조사결과를 바탕으로 대기업과 차별된 중소기업 산업기술 유출방지를 위한 정보보호 관리체계를 설계하고 하였다. 세부적으로 중소기업 산업기술 유출현황 및 취약점 등에 관한 사례를 분석하여 정리하고, 델파이 방법을 적용하여 중소기업 산업기술 유출방지 관리체계를 설계한 다음 이에 대한 적합성을 검증하였다. 본 연구의 결과를 활용하여 중소기업은 적정한 정보보호 투자수준을 산정하고 이에 대한 통제도구를 개발할 수 있을 것으로 기대된다.

고주파 유도가열용 전원장치의 개발에 관한 연구 (A Study on Development of Power Supply for High Frequency Induction Heating)

  • 이봉섭
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.179-186
    • /
    • 2002
  • This paper proposed LC resonant current fed high frequency inverter for high frequency induction heating using leakage inductance of transformer and, its described operating principle. The analysis of circuit presented by using normalized parameter in considering leakage inductance of transformer and, discussed characteristic evaluation of inverter circuit in detail. The proposed inverter is operating ZVS to reduce turn-on and turn-off loss of switching devices so, raised an efficiency. And, the experimental apparatus was made on base characteristic evaluation of theoretical analysis to discuss possibility on high frequency source and confirmed a rightfulness theoretical analysis. A result of study, the proposed inverter is higher utilizing factor using on leakage inductance of transformer and show possibility, which is application on high frequency power system.

  • PDF

동물병원의 방사선발생장치 정도관리에 대한 연구 (Quality Control of Diagnostic X-ray Units for Animal Hospital)

  • 김상우;이지훈;박예슬;임재동;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF