• 제목/요약/키워드: Leakage analysis FEM

검색결과 85건 처리시간 0.024초

고주파 트랜스포머의 권선기법 따른 손실특성 (Power Loss Characteristics according to Winding Method of High Frequency Transformer)

  • 김일남;윤신용;이공희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.49-51
    • /
    • 2004
  • This paper researched the power loss characteristics according to winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM software. The ferrite core model for analysis be used the EE type. Transformer model objected type applied to flyback converter. Therefore, analysis result was obtained the many parameter of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

  • PDF

토로이달 타입 변압기 권선의 Interleaving 효과 분석 (Analysis of Interleaving Effect for Toroidal Type Transformer Windings)

  • 신경구;강병극;정세교
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.255-261
    • /
    • 2015
  • An analysis of the interleaving effect for the secondary winding distribution of a toroidal transformer is presented in this paper. The equations to calculate the leakage inductance of the toroidal transformer are derived using MMF diagrams for the different secondary winding distributions. The simulation and experimental results are provided to show the validity of the theoretical calculation.

슬롯피치 경계 조건을 이용한 인버터 구동 유도 전동기의 회전자 등가회로 정수 추출 및 특성해석 (Analysis of Inverter-Fed Induction Motor Using F.E.M and Harmonic Equivalent Circuit)

  • 이건호;김병태;권병일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권7호
    • /
    • pp.331-338
    • /
    • 2002
  • An inverter-fed induction is driven by a harmonic voltage source so that it is necessary to be analysed by time-stepping F.E.M. But it takes so long time that disadvantageous to design. This paper presents a simple analysis method for inverter-fed induction motor using FEM and harmonic equivalent circuit. First, the rotor bar resistance and the leakage reactance are determinated by FEA for 1 slot region in rotor to consider the skin effect and the saturation. Secondly, the characteristic of the motor is analyzed by the harmonic equivalent circuits consisting of the obtained parameters from the FEA. This method is carried out to analyze an induction motor driven by the sinusoidal voltage and the inverter. The results are verified by comparing with those of the time-step F.E.A and the experiment.

3차원 수치해석에 의한 필 댐의 누수량 평가 (Seepage Quantity Evaluation of a Fill Dam using 3D FEM Analysis)

  • 최병일
    • 한국지반환경공학회 논문집
    • /
    • 제16권8호
    • /
    • pp.45-49
    • /
    • 2015
  • 침투에 대한 안정성 평가 시 댐체의 가장 큰 단면을 반영해 2차원으로 수치해석을 실시하는 것이 일반적이며, 해석결과를 이용한 침투수량 평가 시 댐체 하부지반을 단순한 직사각형 형태로 가정하여 침투수량을 구한 후 단면형상을 반영해 최종 침투수량을 계산하고 있다. 하지만 최근 기술의 발달로 댐 시공 시 다양한 형태의 지반 위에 다양한 형태의 댐들이 축조되고 있는 점을 감안하면 3차원 수치해석을 통해 댐체의 형상 및 지형조건을 보다 정확하게 반영한 결과를 이용하여 결론을 도출하는 것이 바람직하다고 판단된다. 따라서 본 연구에서는 3차원 FEM 수치해석법을 이용하여 강우량을 포함한 다른 기타요인은 배제한 후 댐체로만 통과되는 침투수량 평가를 통해 안전관리를 할 수 있는 방안을 제시하고자 한다.

Levitation and Thrust Forces Analysis of Hybrid-Excited Linear Synchronous Motor for Magnetically Levitated Vehicle

  • Cho, Han-Wook;Kim, Chang-Hyun;Han, Hyung-Suk;Lee, Jong-Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.564-569
    • /
    • 2012
  • This paper proposes a hybrid-excited linear synchronous motor (LSM) that has potential applications in a magnetically levitated vehicle. The levitation and thrust force characteristics of the LSM are investigated by means of three-dimensional (3-D) numerical electromagnetic FEM calculations and experimental verification. Compared to a conventional LSM with electromagnets, a hybrid-excited LSM can improve levitation force/weight ratios, and reduce the power consumption of the vehicle. Because the two-dimensional (2-D) FE analysis model describes only the center section of the physical device, it cannot express the complex behavior of leakage flux, which this study is able to predicts along with levitation and thrust force characteristics by 3-D FEM calculations. A static force tester for a hybrid-excited LSM has been manufactured and tested in order to verify these predictions. The experimental results confirm the validity of the 3-D FEM calculation scheme for the description of a hybrid-excited LSM.

유한요소법을 이용한 등속 조인트 고무 부트의 변형해석 및 설계변경에의 응용 (Stress Analysis of C.V. Joint Rubber Boots by Finite Element Method and Application to Design Modification)

  • 김세호;이형욱;허훈;이종화;오승탁
    • 한국자동차공학회논문집
    • /
    • 제6권3호
    • /
    • pp.123-137
    • /
    • 1998
  • The finite deformation with self contact problem of C. V. joint boots is analysed by using the implicit finite element code ABAQUS/Standard. It is shown that analysis results have a good agreement with experimental ones to the degree of maximum rotation angle. As an application of design modification, the effects of thickness change of the rounded part of boot model on the bending and the contact situation of deformed geometry are investigated. In this paper, the effect of the design modification in the end on the leakage is examined using 2-D finite element simulation. To solve the leakage problem of grease, the length of the small end is enlarged. From this study, it is confirmed that we can save the cost and time by applying FEM techniques to analyze and design the boot model.

  • PDF

지하매설 가스관의 검사를 위한 누설자속탐상 PIG 설계에 관한 연구 (Research on MFL PIG Design for the Inspection of Underground Gas Pipeline)

  • 박상호;박관수
    • 비파괴검사학회지
    • /
    • 제22권2호
    • /
    • pp.177-186
    • /
    • 2002
  • 본 논문에서는 3차원 형태의 결함을 가진 지하매설 가스관에서 누설자속(magnetic flux leakage, MFL) 탐상 법을 사용한 결함 검출에 관하여 연구하였다. 영구자석과 요크로 구성된 자기 시스템을 유한요소법을 사용하여 해석하고 동작점을 설정하였다. 가스관이 충분히 포화되지 않은 경우에는 측정이 곤란하며, 과대포화 된 경우에는 결함에 의한 누설자속의 변화량이 적어서 측정이 곤란하므로 적정한 값을 설정하여야 하므로 자기 시스템의 동작점은 결함이 있을 때 누설자속 증가율이 최대가 되도록 설정하여야 한다. 본 논문에서는 3차원 비선형 유한요소법을 사용하여, 가스관에 결함이 있는 경우 결합의 크기, 깊이에 따른 결함신호를 예측하여 그 결과 가스관 포화상태의 적절여부, 홀 센서 range 및 resolution의 적정도 등을 연구하였다. 또한 홀 센서의 민감도 형장을 위하여 back-yoke를 사용하여 측정신호를 향상시키는 방법을 제안하였다.

지하매설 가스관의 부식 및 결함 탐지를 위한 비파괴 누설 탐상시스템 개발에 관한 연구 (Research on MFL PIG Design for caustic and defect the Inspection of Underground Gas Pipeline)

  • 박상호;박관수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.11-20
    • /
    • 2002
  • 본 논문에서는 3차원 형태의 결함을 가진 지하매설 가스관에서 누설자속(magnetic flux leakage, MFL) 탐상법을 사용한 결함 검출에 관하여 연구하였다. 영구자석과 요크로 구성된 자기 시스템을 유한요소법을 사용하여 해석하고 동작점을 설정하였다. 가스관이 충분히 포화되지 않은 경우에는 측정이 곤란하며, 과대포화된 경우에는 결함에 의한 누설자속의 변화량이 적어서 측정이 곤란하므로 적정한 값을 설정하여야 하므로 자기 시스템의 동작점은 결합이 있을 때 누설자속 증가율이 최대가 되도록 설정하여야 한다. 본 논문에서는 3차원 비선형 유한요소법을 사용하여, 가스관에 결함이 있는 경우 결함의 크기, 깊이에 따른 결함신호를 예측하여 그 결과 가스관 포화상태의 적절여부, 홀 센서 range 및 resolution의 적정도 등을 연구하였다. 또한 홀 센서의 민감도 향상을 위하여 back-yoke를 사용하여 측정신호를 향상시키는 방법을 제안하였다.

  • PDF

가스밸브의 강도안전성에 관한 연구 (A Study on the Strength Safety of a Gas Valve)

  • 김청균
    • 한국가스학회지
    • /
    • 제22권1호
    • /
    • pp.60-63
    • /
    • 2018
  • 본 연구에서는 LPG 용기용 가스밸브의 강도안전성에 대한 FEM 해석결과를 제시하고 있다. FEM 해석결과에 의하면, 가스밸브가 완전히 열린 상태에서 3.5 MPa의 공급압력을 적용하였을 때, 안전밸브와 나사의 상단부사이의 경계 지역에서 발생한 von Mises 최고응력은 99.2 MPa로 나타났다. 99.2 MPa라는 von Mises 최고응력은 황동소재의 항복강도에 비해 낮은 값으로 충분히 안전한 결과이다. 이 경우에, 압력조정기의 상측 오른쪽에서는 최대 변위량 0.002mm가 발생하였다. 최대로 변형된 이 지역은 가스밸브에 설치된 오링이나 다이어프램과 같은 밀봉 부분이 아니므로 의미를 부여할 필요는 없다. 기존의 개폐식 밸브와 압력 조정기를 일체형으로 형성하여 제시한 하이브리드형의 가스밸브 모델은 LPG 용기용으로 가스누출이 없는 메커니즘과 최소로 단순화시킨 크기의 가스모델로 추천된다.

U-컵 시일의 밀봉기구에 관한 유한요소해석 (Finite Element Analysis on the Sealing Mechanism of U-Cup Seals)

  • 최준업;전인기;김희준;김청균
    • Tribology and Lubricants
    • /
    • 제10권3호
    • /
    • pp.12-17
    • /
    • 1994
  • Minimum clearance between the U-cup seal groove of a piston and a cylinder bore to ensure against extrusion of the U-cup ring and leakage of working fluids is an important design parameter for a seal designer in hydraulic cylinder applications. Therefore, typical U-cup seal of a hydraulic actuator has been analyzed as a function of a sealing gap using the nonlinear FEM software MARC. In this study, the useful design data were presented as a function of the sealing gap and the sealed hydraulic pressure.