• Title/Summary/Keyword: Leakage Reduction

Search Result 483, Processing Time 0.03 seconds

Design of Surface-Mounted Permanent Magnet Synchronous Motor Considering Axial Leakage Flux by using 2-Dimensional Finite Element Analysis

  • Lee, Byeong-Hwa;Park, Hyung-Il;Jung, Jae-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2284-2291
    • /
    • 2018
  • This paper deals with optimum design of surface mounted permanent magnet synchronous motor (SPMSM) for automotive component. For a compact system structure, it was designed as a motor with a 14-pole 12-slot concentrated winding and hollow shaft. The motor is a thin type structure which stator outer diameter is relatively large compared to its axial length and is designed to have a high magnetic saturation for increasing the torque density. Since the high magnetic saturation in the stator core increases the axial leakage flux, a 3-dimensional (3-D) finite element analysis (FEA) is indispensable for torque analysis. However, optimum designs using 3-D FEA is inefficient in terms of time and cost. Therefore, equivalent 2-D FEA which is able to consider axial leakage flux is applied to the optimization to overcome the disadvantages of 3-D FEA. The structure for cost reduction is proposed and optimum design using equivalent 2-D FEA has been performed.

Detailed Heat Transfer Characteristics on Rotating Turbine Blade (회전하는 터빈 블레이드에서의 열전달 특성)

  • Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.11 s.254
    • /
    • pp.1074-1083
    • /
    • 2006
  • In the present study, the effect of blade rotation on blade heat transfer is investigated by comparing with the heat transfer results for the stationary blade. The experiments are conducted in a low speed annular cascade with a single stage turbine and the turbine stage is composed of sixteen guide vanes and blades. The chord length and the height of the tested blade are 150 mm and about 125 mm, respectively. The blade has a flat tip and the mean tip clearance is 2.5% of the blade chord. A naphthalene sublimation method is used to measure detailed mass transfer coefficient on the blade. For the experiments, the inlet Reynolds number is $Re_c=1.5{\times}10^5$, which results in the blade rotation speed of 255.8 rpm. Blade rotation induces a relative motion between the blade and the shroud as well as a periodic variation of incoming flow. Therefore, different heat/mass transfer patterns are observed on the rotating blade, especially near the tip and on the tip. The relative motion reduces the tip leakage flow through the tip gap, which results in the reduction of the tip heat transfer. However, the effect of the tip leakage flow on the blade surface is increased because the tip leakage vortex is formed closer to the surface than the stationary case. The overall heat/mass transfer on the shroud is not affected much by the blade rotation.

Corrosion Reduction Techniques of Pipe Line Net Using DVGW (DVGW이론에 따른 상수관망의 부식방지에 관한 연구)

  • Choo, Tai-Ho;Kim, Ha-Il;Je, Sung-Jin;Ok, Chi-Youl
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.11
    • /
    • pp.310-316
    • /
    • 2006
  • Leakage of waterworks pipe line net cause loss of water resources, additional foundation of pressurization facilities from pressure loss and soil weakening near leaked pipe line, etc.. This makes it difficult to maintain and manage waterworks pipe line net and so cause serious economic loss. The rate of accounted water can be improved by monitoring always water pressure and flux, and so on. from isolated region, preparing positively against leakage accident and preventing leakage from occurring. Actually after isolating region, average rate of accounted water in this region went up 88.94% by continuously monitoring control of water pressure and inflow rate. It is about 9.44% higher than that of Busan metropolitan city in 2003, 79.5%.

  • PDF

Study on designing of Flat Transformer and operating characteristics of Converter (Flat Transformer 코아의 설계와 컨버터 동작 특성)

  • Han, Se-Won;Cho, Han-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.587-590
    • /
    • 2003
  • The first attention in designing a transformer for low temperature rise should be to reduce losses. Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

A Plan to Ensure Safety of Electric Installation in Empty houses During Normal Working Hours (부재수용가의 전기설비에 대한 안전확보 방안)

  • Lim, Young-Bae;Jung, Jong-Wook;Jung, In-Soo;Bae, Seok-Myung;Cho, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.25-26
    • /
    • 2006
  • An electrical fault is defined as any abnormal condition caused by reduction in the insulation strength between energized conduction parts and ground or any grounded part of an electrical system. Failure of solid insulation can be caused by excessive mechanical tension being applied on the insulation, harsh service environment, aging, and also by corona phenomena. The number of empty houses during normal working hours is rising. As a result, the number of uninspected electric installation for general use is increasing. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value can not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed.

  • PDF

A Lubrication Performance Analysis of Mechanical Face Seals Using Galerkin Finite Element Method (갤러킨 유한요소해석법을 이용한 미케니컬 페이스 실의 윤활성능해석)

  • Choe, Byeong-Ryeol;Lee, An-Seong;Choe, Dong-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.6
    • /
    • pp.916-922
    • /
    • 2001
  • A mechanical face seal is a tribo-element intended to control leakage of working fluid at the interface between a rotating shaft and its housing. Leakage of working fluid decreases drastically as the clearance of the mating seal faces gets smaller. But the very small seal clearance results in an increased reduction of seal life because of high wear and heat generation. Therefore, in the design of mechanical face seals a compromise between low leakage and acceptable seal life is important, and it presents a difficult and practical design problem. A fluid film or sealing dam geometry of the seal clearance affects seal lubrication performance very much, and thereby it is one of the main design considerations. In this study the Reynolds equation for the sealing dam of mechanical face seals is numerically analyzed, using the Galerkin finite element method, which is readily applied to various seal geometries. Film pressures of the sealing dam are analyzed, including the effects of the seal face coning and tilt. Then, lubrication performances of the seals, such as opening forces, restoring moments, leakage, and dynamic coefficients, are calculated, and they are compared to the results obtained by the narrow seal approximation.

THE EFFECT OF DENTIN BONDING AGENTS ON MARGINAL LEAKAGE FOLLOWING RESTORATION ON THE CERVICAL ABRASION (치경부 마모증 수복시 상아질 접착제가 변연누출에 미치는 영향)

  • Koo, Bon-Wook;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.2
    • /
    • pp.55-63
    • /
    • 1987
  • The purpose of this study is to evaluate the effect of dentin bonding agents on marginal leakage. V-shaped cavities were prepared on the faciocervical area of 140 extracted human teeth. In Groups of twenty cavities, they were restored as follow: Group 1 with enamel bonding resin and Silux, Group 2 Scotchbond and Silux, Group 3 enamel bonding resin and Heliomolar, Group 4 Dentin Adhesit and Heliomolar, Group 5 enamel bonding resin and Durafill, Group 6 Dentin Adhesive and Durafill, Group 7 Chembond. All specimens were thermocycled alternatively at $4^{\circ}C$ and $60^{\circ}C$ of 2% methylene blue dye solution, and sectioned faciolingually with diamond disk under water spray. The sectioned specimens observed with stereo microscope. Following results were obtained: 1. The groups filled with Scotchbond-Silux or Dentin Adhesit-Heliomolar had appeared lesser marginal leakage compared with the groups with enamel bonding resin-Silux or enamel bonding resin-Helimolar. 2. The group filled with Dentin Adhesive-Durafill did not show the reduction of the marginal leakage compared with the group with enamel bonding resin-Durafill. 3. There was significant difference among the four dentin bonding agents. Scotchbond showed the greatest marginal sealing ability, and Dentin Adhesit was the next. The marginal sealing ability of Dentin Adhesive was the worst.

  • PDF

A Study on the Effect of Damages on the Conditions of Dike in the Leakage of Hydrochloric Acid Storage Tank (염산 저장탱크 누출 시 방류벽 조건에 따른 피해영향 연구)

  • Kang, Jungchun;Kim, Seungha;Kim, KyuHwan;Kim, YeonSoo;Kwon, Donguk
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.7-12
    • /
    • 2018
  • Hydrochloric acid is a highly corrosive toxic substance and requires proper safety to minimize damage in case of leakage. Among the various risk-reduction facilities, the dike is a typical safety facility installed to protect the surrounding buildings and facilities by preventing the external spread of hazardous materials from the storage tank. In this study, the KORA program was used to assume leakage accident of hydrochloric acid storage tank. At this time, the extent of the damage effects of ERPG-2 were assessed for each of the three separation distance between the storage tank and the dike. The study found that the smaller the separation distance between the dike and the storage tank, the smaller the extent of damage caused by hydrochloric acid leakage, and the greater the impact of indoor conditions under the same conditions. Through this process, we are going to assist in selecting locations and installing facilities for new and existing businesses.

Reduction of EMI Generated by a PWM Inverter-Fed AC Motor Dirve System

  • Ogasawara, Satoshi;Akagi, Hirofumi
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.452-457
    • /
    • 1998
  • This paper deal with problems of leakage current, shaft voltage, bearing current, and EMI, in valiable-speed AC drives. The originating mechanism is illustrated with a high-frequency equivalent circuit. Reduction methods are classified in to six categories based on the equivalent circuit. Some experimental results show that a common-mode transformer (CMT) and a common-noise canceler (ACC) can solve the problems, which have been proposed the authors.

  • PDF

Assessment of Formwork-Seepage Minimization in High Fluidity, Normal Strength Concrete Utilizing Thixotropic Properties (고유동 일반강도 콘크리트의 요변성 부여에 따른 거푸집 누출 저감 성능 분석)

  • Kim, Young-Ki;Lee, Yu-Jeong;Kim, In-Tae;Han, Dong-Yeop
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.4
    • /
    • pp.337-348
    • /
    • 2023
  • The central objective of this study is to curtail the leakage of mortar or cement paste, often resultant of ill-constructed formwork, by implementing thixotropy in the formulation of high-fluidity, standard-strength concrete. When such concrete is utilized in smaller scale construction projects, instances of formwork gaps due to suboptimal construction precision may lead to significant leakage of mortar and paste, a problem not typically encountered with traditional slump-flow concrete. In this investigation, Polyvinyl Alcohol(PVA) and borax are incorporated into the concrete mixture to induce thixotropy. The experimental design includes varying methodologies for integrating PVA and borax, while assessing alterations in diverse concrete performances, including thixotropy and leakage reduction potential that simulates formwork gap conditions. Under the experimental conditions defined within this study, it was found that replacing, rather than merely adding PVA and borax, aids in averting water addition via suspensions. This approach yielded promising results in terms of concrete properties and proved efficacious in stemming leakage in concrete possessing sufficient thixotropy. Notably, when a 6% PVA suspension was substituted, a significant reduction in leakage was observed. Consequently, it is projected that construction quality can be ensured, even with lower precision formwork, by applying thixotropy to concrete through the use of PVA and borax.