• 제목/요약/키워드: Leakage Rates

검색결과 216건 처리시간 0.027초

축류 회전차 익말단 틈새유동에 대한 수치해석(II) - 틈새변화 및 영각변화에 따른 누설와류의 변화 - (Numerical Analysis on the Blade Tip Clearance Flow in the Axial Rotor (II) - Variation of Leakage Vortex with Tip Clearance and Attack Angle -)

  • 노수혁;조강래
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1106-1112
    • /
    • 1999
  • Substantial losses behind axial flow rotor are generated by the wake, various vortices in the hub region and the tip leakage vortex in the tip region. Particularly, the leakage vortex formed near blade tip is one of the main causes of the reduction of performance, generation of noise and aerodynamic vibration in downstream. In this study, the three-dimensional flow fields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The numerical technique was based on SIMPLE algorithm using standard $k-{\varepsilon}$ model(WFM) and Launder & Sharma's Low Reynolds Number $k-{\varepsilon}$ model(LRN). Through calculations, the effects of tip clearance and attack angle on the 3-dimensional flow fileds behind a rotor and leakage flow/vortex were investigated. The presence of tip leakage vortex, loci of vortex center and its behavior behind the rotor for various tip clearances and attack angles was described well by calculation.

초장대 해저터널의 공사중 덕트 접속부의 누풍 성능 개선에 관한 연구 (A study on the air leakage performance improvement of duct coupling for temporary ventilation of long subsea tunnel)

  • 조형제;민대기;김종원;이주경;백종훈
    • 한국터널지하공간학회 논문집
    • /
    • 제19권2호
    • /
    • pp.319-333
    • /
    • 2017
  • 초장대 해저터널의 건설은 건설공간의 제약 및 건설비용 측면에서, 공사중에 사용되는 환기 시스템 설치에 유리한 조건을 갖고 있지 않다. 공사중 환기시스템을 제공하기 위해, 환기갱이 설치되는 인공섬들이 해저터널의 루트를 따라서 일부위치마다 건설됨으로써, 건설 비용이 많이 소요된다. 따라서 이러한 인공섬의 수를 최소화하는 것이 경제적으로 필요하다. 그러나 이것은 환기갱 사이의 거리가 더 길어지게 되므로, 필요한 환기풍량을 이송하기 위한 높은 팬 압력으로 인해 환기 덕트 접속부에서 누풍이 더 많이 발생하게 된다. 선행 연구에서 공기 누설이 중요한 문제임을 조명하였다. 본 연구는 개선된 덕트 접속 방식을 개발하기 위한 실험들을 소개하고, 또한 SIA 의 "S" 등급 누풍율 및 다양한 조건들을 비교하여 터널 연장에 따른 달성된 누풍율의 환기 성능을 제시한다. 본 연구의 결과로 누풍율이 $1.46mm^2/m^2$인 새로운 접속방식을 개발하였으며, 개선된 방식이 30 km규모의 장대터널에 적합한 것으로 분석되었다.

위암의 정규 위절제술 후 발생한 문합부 누출의 치료 결과 (The Result of Treatment of Anastomotic Leakage after an Elective Gastrectomy for an Adenocarcinoma)

  • 심요섭;김찬영;양두현
    • Journal of Gastric Cancer
    • /
    • 제4권3호
    • /
    • pp.164-168
    • /
    • 2004
  • Purpose: The most feared complication of gastrointestinal tract operations is anastomotic leakage, not only because of the presumed individual surgeon's culpability but also because of the assumption that this event is often fatal. We have experienced 32 cases of anastomotic leakage after elective gastric resection during 8 years. The purpose of this study was to evaluate the result of their treatment. Materials and Methods: We evaluated the records of 1335 patients who had undergone elective gastric resection for an adenocarcinoma of stomach from January 1995 to October 2003 and conducted a retrospective, multivariate analysis. Results: Of the 1335 patients, 32 ($2.4\%$) sustained an anastomotic leakage. Anastomotic leakages usually developed on mean postoperative day $9.1\pm3.2$ (range:$1\∼18$ days).Overall, $31.3\%$ (10/32) of patients who sustained an anastomotic leakage died. The anastomotic leakages were identifed by radiological study or by operative finding at the site of the duodenal stump (20 patients), the esophagojejunostomy (7), the gastroduodenostomy (4), and the gastrojejunostomy (1). Fourteen patients ($43.8\%$) underwent a relaparotomy, a drainage procedure in the main, and 18 patients ($56.3\%$) were treated conservatively. The mortality rates were $42.9\%$ (6/14) and $22.2\%$ (4/18), respectively, but this difference was not statistically significant. A cox's proportional hazard analysis showed that a body-mass Index < 24 kg/m2 (odds ratio 5.55, $95\%$ CI: $0.69\∼44.82$) and non-enteral feeding (odds ratio 18.27, $95\%$ CI 2.22.150.69) were independent factors of mortality due to anastomotic leakage. Conclusion: Our observations show that anastomotic leakage after an elective gastric resection has a high risk of being fatal. Moreover, for a patient with a body-mass index lower than $24\;kg/m^{2}$ and/or non-enteral feeding, an anastomotic leakage after an elective gastric resection has a higher risk of being fatal.

  • PDF

모래자갈과 누수성 토질을 기반으로하는 용수로의 누수방지에 대한 연구 (A Study on the Leakage Interception Work in the Irrigation Canal Founding on the Sandy Gravel or the Porous Soil)

  • 강신업
    • 한국농공학회지
    • /
    • 제12권2호
    • /
    • pp.1965-1970
    • /
    • 1970
  • The experiment was carried out in order to improve the leakage stopping work in the irrigation canal founding on the porous soil. But the experiment had many problems to be studied more owing to the insufficient time and facilities. The results obtained are summarized as follows; 1. Polyethylene film is estimated not to make strength decrease owing to buring in the subsoil, but to make owing to the sunlight. 2. Coated nylon shows the tendency to deteriorate strength when it is buried in the earth or exposed to the sun for long time, but leakage is all but impermeability generally. 3. Leakage loss rates for one hour show some differences in the canal to be full with water in accordance with operating methods, that is, the clay lining section is 12.6%, the coated nylon lining section is 1.7%, the polyethylene film lining section is 1.3%, respectively. 4. Leakage quantities per wetted perimeter unit area show $3.556cc/cm^2/hr$. in the clay lining section, $1.574cc/cm^2/hr$. in the coated nylon section, $0.695cc/cm^2/hr$. in the polyethylene film lining section, respectively. 5. When the construction fund make the clay lining section as a standard, the polyethylene film section is 92.1%, the coated nylon section is 174.2%, respectively. But, the unit cost of execution may be low when the polyethylene film and the coated nylon will enable to mass-produce for the purpose of execution.

  • PDF

여러 환경조건에 대한 고분자애자의 누설전류 특성 변화 (Variation in Leakage Current Characteristics of Polymer Insulator for Various Environmental Condition)

  • 박재준;최인혁;이동일
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.169-175
    • /
    • 2006
  • This study investigated variation leakage current maximum value and waveform considering applied voltage phase angel by simulating three environmental conditions, such as fog, salt fog, and kaolin contamination .As the result of applied voltage phase angel characteristics, leakage currents presented almost in phases in the early stage regardless of environmental conditions just after applying the voltage, and the phase of leakage currents certain phase lags for the discharge of the applied voltage when surface discharges occurred due to the continuous environmental contamination. In addition, the difference in phase significantly increased according to the intensity of discharges. The change in distortion rates according to the environmental contamination presented a nearly same level just after applying the voltage. The distortion rate of third harmonic for the fundamental wave presented by the order of fog>salt fog>kaolin when surface discharges occurred due to the applied voltage for certain continued periods. In the case of the fog and salt fog, the scale of spectrums decreased according to the increase in frequencies from the results of the analysis of high frequencies. In addition, the even number frequency presented a relatively large level compared to the odd number frequency under the kaolin contamination.

A Polycrystalline CdZnTe Film and Its X-ray Response Characteristics for Digital Radiography

  • Kim, Jae-Hyung;Park, Chang-Hee;Kang, Sang-Sik;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제4권5호
    • /
    • pp.15-18
    • /
    • 2003
  • The Cd$\_$1-x/Zn$\_$x/Te film was produced by thermal evaporation for the flat-panel X-ray detector. The crystal structure and the surface morphology of poly crystalline Cd$\_$1-x/Zn$\_$x/Te film were examined using XRD and SEM, respectively. The leakage current and X-ray sensitivity of the fabricated films were measured to analyze the X-ray response characteristic of Zn in a polycrystalline CdZnTe thin film. The leakage current and the output charge density of Cd$\_$0.7/Zn$\_$0.3/Te thin film were measured to 0.3 1nA/$\textrm{cm}^2$ and 260 pC/$\textrm{cm}^2$ at an applied voltage of 2.5 V/$\mu\textrm{m}$, respectively. Experimental results showed that the increase of Zn doping rates in Cd$\_$1-x/Zn$\_$x/Te detectors reduced the leakage current and improved the X-ray sensitivity significantly. The leakage current was drastically diminished by the formation of thin parylene layer in the Cd$\_$0.7/Zn$\_$0.3/Te detector.

사판식 액시얼 피스톤 펌프의 가변용량 시스템의 특성에 관한 연구 (A Study on Characteristics of a Compensator System for Swash Plate Type Axial Piston Pump)

  • 김신;오석형;정재연
    • Tribology and Lubricants
    • /
    • 제14권4호
    • /
    • pp.15-22
    • /
    • 1998
  • Recently, the importance of variable displacement piston pump is increasing in industrial world. Especially, most consumers require various range of pressures and flow rates. Pressure compensator is a system controlling flow rate in piston pump at low cost and, therefore, satisfies the need of consumers. However, the system has serious problems, such as response and leakage. The response and leakage are affected by clearance between actuator piston and cylinder, roughness of surface, and spool overlap. In this paper, these effects are investigated experimentally, and optimal clearance and chamfer is obtained. While diameter of cylinder is fixed and diameter of actuator piston is changed in this experiment, response and leakage are measured. Also parameters such as roughness and processing accuracy are changed for piston of fixed clearance. Experimental setup modelled into several parts of actuator piston, cylinder, spool, and swash plate. Input pressure is changed by function generator and proportional valve. The result of this experiment shows that leakage increases very much in proportion to the increase of clearance, and especially leakage occurs enormously when clearance is more than 0.002. The response is not good because as clearance increases leakage increases and as clearance decreases viscous damping effect increases. Accordingly, it is found out that optimal clearance range exists for tile response, within about 0.0012∼0.0014, at this time. Futhermore, the better roughness and geometrical accuracy of actuator piston are, the smaller are leakage and friction. The paper informs that response and leakage are influenced by and geometrical accuracy of actuator piston, roughness of surface, and the clearance between actuator piston and cylinder, and that optimal design of actuator piston in the pressure compensator is possible.

원전 격납건물 국부누설률시험에서의 압력감소법을 이용한 과다누설 측정 방법 (Excessive Leakage Measurement Using Pressure Decay Method in Containment Building Local Leakage Rate Test at Nuclear Power Plant)

  • 이원규;김창수;김왕배
    • 비파괴검사학회지
    • /
    • 제36권3호
    • /
    • pp.231-235
    • /
    • 2016
  • 원자력발전소에서 격납건물 국부누설률시험(LLRT)에 사용되는 누설률 측정 방법에는 유량보충법과 압력감소법이 있으며, 대부분의 발전소에서는 유량보충법을 우선 적용하고 있다. 유량보충법은 누설되는 양만큼 보충되는 유량을 측정하여 누설률을 계산하는 방식이다. 그러나 과도한 누설이 발생하여 시험압력 유지가 어려울 경우 압력감소법이 보완적으로 사용될 수 있다. 압력감소법은 시험압력보다 낮은 압력을 적용하여 누설률을 측정할 수 있기 때문이다. 본 논문에서는 원자력발전소 격납건물 국부누설률시험에서 압력감소법을 이용한 과다누설 측정 방안을 연구하고자 하였다. 이에 따라 현장에서의 누설시험 조건과 유사하게 실험장치를 구성하여 실증실험을 수행하였다. 실험 결과 압력감소법에서의 누설률 변화 특성을 확인하였으며, 여러조건에서 측정된 누설량을 바탕으로 실제 누설률 계산에 필요한 보상비를 산출하였다.

경사 그루브를 갖는 평판 실의 압력 강하 및 누설 성능 (Pressure Drop and Leakage Performances of Flat Seals with Inclined Grooves)

  • 정진우;정권종;황성호;김태호;김어진
    • Tribology and Lubricants
    • /
    • 제38권5호
    • /
    • pp.213-221
    • /
    • 2022
  • This paper presents performance measurements of pressure drop and leakage flow rate of test flat seals with asymmetric inclined grooves. This study aims to reveal the influence of groove shapes, often machined in radial film riding-face seals, in forming a hydrodynamic wedge on leakage performance. A test facility was developed, and test seals were manufactured to study the effects of the inlet pressure level, ratio of inlet to outlet pressure, seal groove length, and seal groove height on the steady-state pressure drop and leakage performance. A series of tests were conducted, and the test data were compared to the predictions from a simple and efficient mathematical model using a one-dimensional Reynolds equation. The test results revealed that an increase in the inlet pressure increased the pressure drop through the test seals. The leakage flow rate increased significantly as the inlet pressure and ratio of the inlet to outlet pressure increased. The groove shape also affects seal performance. An increase in the groove length and height resulted in an evident increase in the leakage flow rate. The simple model predictions underestimated the leakage flow rates but showed good agreement with the trend in the measurements for all test operating conditions and changes in the groove shape.

Dosimetrical Analysis of Reactor Leakage Gamma-rays by Means of Scintillation Spectrometry

  • Jun, Jae-Shik
    • Nuclear Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.291-309
    • /
    • 1973
  • TRIGA Mark II와 III 원자로의 여러가지 가동조건에 있어서 노벽으로 부터의 누설 ${\gamma}$선에 의한 조사선양률을 3"$\times$3"원통형 NaI(T1) 섬광계수기와 400 channel파 고분석장치로 측정하였는데 측정된 spectrum으로부터 조사선양률을 산출하는데는 실제적면에서 복잡하기 짝이 없는 response matrix 방법대신 정도가 좋으면서도 비교적 그 과정이 단순한 Moriuchi의 specturm -조사선양률 환산 이론을 적용하였다. 연구결과에 따르면 노심에서 발생된 누설 ${\gamma}$선의 기본적인 spectrum 형태는 원자로의 열출력이나 차장벽에 의한 강도의 감쇠에 별로 영향을 받지 않고 있으며 원자로 누설${\gamma}$선에 의란 전조사선양률의 공기중에서의 감쇠는 폭 넓은 energy분포에도 불구하고 지수함수적 감쇠를 하고 있음이 판명되있다. 이 전조사선양률은 원자로의 열출력에 대체로 비례하고 있으나 TRIGA Mark III과 같은 가동형노심의 경우는 측정된 spectrum이 매우 다양한바, 그로부터 산출된 전조사선양률의 크기에는 관계없이, spectrum 분해방법을 적용하여 노심에서 발생된 누설 ${\gamma}$선과 원자로가동중 발생되는 여지 ${\gamma}$선의 기여를 판별 해석하는데 성공하였다.

  • PDF