• Title/Summary/Keyword: Leakage Prevention

Search Result 316, Processing Time 0.024 seconds

Measures to Prevent the Leakage of Military Internal Information through the Analysis of Military Secret Leakage Cases: Focusing on Insider Behaviors (군사기밀 유출 사례 분석을 통한 군 내부정보 유출 방지 방안 : 내부자 행위 중심으로)

  • Eom, Jung-Ho;Kim, Nam-Uk
    • Convergence Security Journal
    • /
    • v.20 no.1
    • /
    • pp.85-92
    • /
    • 2020
  • None of the recent cases of military secret leakages have leaked internal information using networks. This is because the Internet and the Intranet are physically separated, and has a difficult process when transmitting and receiving data through the Internet. Therefore, most of the leaked paths are to copy and hand over secrets, shoot and send them with a smartphone, or disclose after remembering them. So, the technology of blocking and detecting military secret leakages through the network is not effective. The purpose of this research is to propose a method to prevent information leakage by focusing on the insider behaviors, the subject of leakage, rather than the military secret. The first is a preventive measure to prevent the leakage behavior of military secrets, the second is to block suspicious access to the military secret data, and the last is to detect the leakage behavior by insiders.

A Study on Application of Electrical Resistivity Survey to Detect the Leakage of Embankment with Weak Zone (취약대가 존재하는 제방의 누수 탐지를 위한 전기비저항 탐사의 적용성 연구)

  • Park, Samgyu;Kim, Jaehong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.4
    • /
    • pp.5-13
    • /
    • 2013
  • The water leakage of reservoir embankment usually occurs around channelling pipes, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain and the rainy season in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disaster prevention and embankment maintenance. The water leakage in dams and levees where the channelling pipes are working as weak zone was analyzed by using both numerical simulation and experimental method in this study. To detect the water leakage, an electrical resistivity survey was used and investigated for its' usability. The numerical results show the size and location of weak zone increases the importance of selection of electrode spacing. The leakage experiments of model embankment present the best result is obtained under the conditions of electrode spacing of 0.3m and dipole-dipole array. By studying the water leakage in dams and levees, the electrical resistivity survey is observed it is a very useful method to predict the leakage.

Development of mA Level Active Leakage Current Detecting Module (mA급 유효성분 누설전류 감지 모듈 개발)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.1
    • /
    • pp.109-114
    • /
    • 2017
  • In this study, we have developed the active leakage current detection module based on a MSP430 processor, 16bit signal processor. This module can be operated in a desired trip threshold within 0.03 seconds as specified in KS C 4613. This developed module is expected to be applicable as a module for prevention of electric shock in smart distribution panel of smart grid.

Military Application of Two-factor Authentication to Data Leakage and Access Prevention (데이터 유출 및 접근방지를 위한 이중 인증방식의 군(軍) 적용방안)

  • Jung, Ui Seob;Kim, Jee Won;Kim, Jae Hyun;Jeong, Chan ki
    • Convergence Security Journal
    • /
    • v.18 no.5_2
    • /
    • pp.21-27
    • /
    • 2018
  • Most of the Internet users in Korea are issued certificates and use them for various tasks. For this reason, it is recommended that accredited certification authorities and security related companies and use public certificates on USB memory and portable storage devices rather than on the user's desktop. Despite these efforts, the hacking of the certificate has been continuously occurring and the financial damage has been continuing. Also, for security reasons, our military has disabled USB to general military users. Therefore, this study proposes a two-factor method using the unique information of the USB memory and the PC which is owned by the user, and suggests a method of managing the private key file secure to the general user. Furthermore, it will be applied to national defense to contribute to the prevention of important data and prevention of access by unauthorized persons.

  • PDF

The Study of Improvement of Personal Information Leakage Prevention in Mobile Environment (모바일 환경에서 개인정보 유출 방지를 위한 개선 연구)

  • Choi, Heesik;Cho, Yanghyun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.3
    • /
    • pp.53-62
    • /
    • 2015
  • Recently, number of tablet or Smartphone users increased significantly in domestic and around the world. But violation of personal information such as leakage, misuse and abuse are constantly occurring by using mobile devices which is very useful in our society. Therefore, in this paper it will talk about the problems in the network environment of the mobile environment such as tablet and Smartphone, Mobile Malware, hacking of the public key certificate, which could be potential threat to mobile environment. This thesis will research for people to use their mobile devices more reliable and safer in mobile environment from invasion and leakage of personal information. In order to use Smartphone safely, users have to use Wi-Fi and Bluetooth carefully in the public area. This paper will research how to use App safely and characteristic of risk of worm and Malware spreading. Because of security vulnerabilities of the public key certificate, it will suggest new type of security certification. In order to prevent from the information leakage and infect from Malware in mobile environment without knowing, this thesis will analyze the improved way to manage and use the mobile device.

The Selter Selection Plan due to Formaldehyde Leakage (산화프로필렌의 누출영향평가에 따른 안전거리 산정)

  • Seongju Oh;Sanghun Han;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.11-22
    • /
    • 2024
  • This study aims to present safety distances by the damage impact assessment of the leakage of propylene oxide. As a result of the experiment, the pressure 1psi range was 52m to 169m, the radiant heat 18kW/m2 range was 63m to 163m, the AEGL-2 range was analyzed as 224m to 414m, and the fire ball diameter was analyzed to be 45m to 121m. Additionally, the extent of damages was proportional to the amount of propylene oxide stored or handled. The safe distance for a 10% lethality due to overpressure and radiant heat was calculated to be 134m, and the safe distance for a 0% lethality was 169m. Toxicity was measured at 134m with a lethality 0%. Therefore, the safety distance due to leakage of propylene oxide is calculated to be between 134m and 169m.

Consumer Awareness Analysis of Residential Building Underground Structure Leakage Prevention Measurements (공동주택 지하공간 누수 예방 기술 정책 수립을 위한 소비자 인식 분석 연구)

  • Han, Yoon-Jung;Oh, Kyu-Hwan;Kim, Su-Ryon;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.379-387
    • /
    • 2016
  • In this study, a survey was conducted on the required measurement and waterproofing performance for residential building underground structure leakage prevention system. According to the results of the survey, it has been determined that leakage problem is considered to be quite severe, and many respondents have agreed. The legal guidelines and regulation systems do not reflect properly on the environmental requirements or conditions, resulting in continued leakage problem. In regards to this, a standardized waterproofing technique that can be used in underground areas of residential structures is required as an obligation and the development of high performance waterproofing method that allows for wet concrete surface adhesion and a guideline, design and maintenance method that allows the control of overall situational control of leakage is required.

Development of the Automobile Part for the Engine Oil Leakage Prevention by the Precise Cold Forging (정밀냉간단조에 의한 엔진오일 누수방지용 자동차부품 개발)

  • Kwon H. B.;Lee B. K.
    • Transactions of Materials Processing
    • /
    • v.14 no.8 s.80
    • /
    • pp.675-680
    • /
    • 2005
  • This study was aimed at the design of the dies for the automobile part for the engine oil leakage prevention using the computer simulation to shorten the period of production, on the basis of the process planning which was designed by the field experts. In the computer simulation,'eesy-2-form' of 2D FEM simulation package and 'eesy-DieOpt' have been used, which are the commercial process analysis and die design program. Through the simulation of 'eesy-2-form', we could know the propriety of the forming process, the inner pressure of the die and the suitable fitting pressure between the insert and the sleeve which was not showing any positive tangential stresses in the insert. Through the simulation of 'eesy-DieOpt', we could know the number of the stress ring, the diameter ratios, the stresses of the die, the shrink fitting tolerance and temperature in the condition of the already determined maximum outer die diameter of the multi-stage former. The validity of the die design using the computer simulation was analyzed by the experiments and the results were satisfactory. As the results of this study, the new and easy die design system for cold forging has been developed.

The Survey of Fire Hazard of Fan in Manufacturing Industries (제조 사업장의 환풍기 화재위험성 조사)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.21-29
    • /
    • 2013
  • The short circuit and overload is presented by main cause of electrical fire. However, 85% of the fan directly connected the outlet box without switch in total 110 fans as a research in manufacturing industries. In installation direction of vertical type fans which was placed on the horizontal surface, only 39 vertical type fans were placed on vertical surface and 71 fans were placed on the horizontal type. The installation direction of the fans warns of the risk of the fire hazard due to the motor stall to the user manual of the maker. However, it is the representative nonconformity example of construction which the people or builder disregards. In addition, the condition of ground connection with the earth leakage prevention was investigated in grounding of 5 fans, non-grounding of 105 fans. The double insulation structure is generally used for small fan and it can't connect ground wire as electric plug of non-grounding type. However, industrial iron fan needs ground wire for electric leakage and to protect against electric shock.

Security-equipment building cause based on 「grounded theory」 approaches (융합보안 설비구축 원인에 대한 근거이론적 접근)

  • Lim, Heon-Wook
    • Convergence Security Journal
    • /
    • v.16 no.7
    • /
    • pp.69-75
    • /
    • 2016
  • The government is to prevent technology leakage in 2007, the Industrial Technology Protection Act was enacted and encouraging deployment of security equipment. in this study, corporate security equipment for the tried to determine the cause. In contrast to quantitative research, which is an existing research method, Barney G. Glaser & Anselm L. Strauss used a grounded theory as a kind of qualitative methodology in social science. As a result, it was found that the higher the government subsidy, the request from the representative or the client, the higher the efficiency through the prevention of technology leakage, the higher the sales increase, In the United States.