• Title/Summary/Keyword: Leakage Measurement

Search Result 501, Processing Time 0.5 seconds

An Evaluation of Airtightness Performance and Analysis of Energy Savings Potential in Apartment Housing (공동주택의 기밀성능 평가 및 에너지 절감효과 분석)

  • Leigh, Seung-Bok
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.119-125
    • /
    • 1995
  • Since the using of heating energy associated with infiltration is significant in a building, the efforts to minimize the infiltration while ensuring minimum ventilation rates for various types of occupancy will be beneficial. In constrast to that many efforts have been made to reduce heat loss by improving thermal resistance of building envelope, little has been tried to reduce heat loss from infiltration. For achieving such an objective, measurement of air leakage rate will be pre-requisite as a diagnostic tool. A blower door system, a depressurization/pressurization method, was employed and it demonstrated a good potential for measuring airtightness performance of residential buildings. Based on the test results, annual energy savings for residential heating was estimated by reducing infiltration to a level of reasonably airtight or to a level of ASHRAE Standard 62-1989 for minimum ventilation.

  • PDF

Humidity Calibration for a Pressure Gauge Using a Temperature-Stable Quartz Oscillator

  • Suzuki, Atsushi
    • Applied Science and Convergence Technology
    • /
    • v.25 no.6
    • /
    • pp.124-127
    • /
    • 2016
  • Humidity calibration for a temperature-stable quartz oscillator (TSQO) was investigated to exclude the influences of relative humidity on the TSQO output in order to use the corresponding devices outdoors. The TSQO output is a voltage that is inversely proportional to the electric impedance of the quartz oscillator, which depends on the viscosity and density of the measured gas. The TSQO output was humidity calibrated using its humidity dependence, which was obtained by varying the relative humidity (RH) from 0 to 100 RH% while other conditions were kept constant. The humidity dependencies of the TSQO output were fit by a linear function. Subtracting the change in the TSQO output induced by the change in humidity, calculated with the function from the experimentally measured TSQO output for a range of 0-100RH%, eliminated the influence of humidity on the TSQO output. The humidity calibration succeeded in reducing the fluctuations of the TSQO output from 0.4-3% to 0.1-0.3% of the average values for a range of 0-100RH%, at constant temperatures. The necessary stability of the TSQO output for application in hydrogen sensors was below one-third of the change observed for a hydrogen leakage of 1 vol.% hydrogen concentration, corresponding to 0.33% of the change in each background. Therefore, the results in this study indicate that the present humidity calibration effectively suppresses the influence of humidity, for the TSQO output for use as an outdoor hydrogen sensor.

Industry safety characteristic of Prismatic EDLCs (각형 전기이중층 커패시터의 산업 안전성)

  • 김경민;장인영;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.247-257
    • /
    • 2004
  • Electrodes were fabricated based on activated carbon powder BP-20, conducting agent such as Super P, vapor grown carbon fiber (VGCF) and acetylene black (AB), and the mixed binders of flexible poly(vinylidenefluoridehexafluoropropylene) [P(VdF-co-HFP)] and cross linking dispersion agent of polyvinylpyrrolidone (PVP) to increase mechanical strength. According to impedance measurement of the electrode with the addition of conducting agent, we found that it was possible to charge rapidly by the fast steady-state current convergence due to low equivalent series resistance (AC-ESR, fast charge transfer rate at interface between electrode and electrolyte and low RC time constant. The self-discharge of unit cell showed that diffusion process was controlled by the ion concentration difference of initial electrolyte due to the characteristics of Electric Double Layer Capacitor (EDLC) charged by ion adsorption in the beginning, but this by current leakage through the double-layer at the electrode/electrolyte interface had a minor effect and voltages of curves were remained constant regardless of electrode material. We found that the 2.3V/230F grade EDLC would be applied to industrial safety usage such as uninterrupted power supply (UPS) because of the constant DC-ESR by IR drop regardless of discharge current.

  • PDF

Effect of Rapid Thermal Annealing and Orientation of Si Substrate on Structural and Electrical Properties of MOCVD-grown TiO2 Thin Films (급속 후 열처리 및 실리콘기판 배향에 따른 MOCVD-TiO2박막의 구조적.전기적 특성)

  • 왕채현;최두진
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.1
    • /
    • pp.88-96
    • /
    • 1998
  • The structural and electrical properties of titanium dioxide(TiO2) thin films deposited on p-type (100) si and 4$^{\circ}$off(100) Si substartes by metalorganic chemical vapor deposition (MOCVD) have been studied with post rapid thermal annealing. TiO2 thin films of anatase phase were grown at 300-500$^{\circ}C$ using titanium post rapid thermal annealing at a temperature of 800$^{\circ}C$ for 30sec. rutile phase was observed in the condition of the deposition temperature over 350$^{\circ}C$ in the ambient air atmosphere and at 500$^{\circ}C$ in cacuu,. SEM and AFM study show-ed surface roughness were increased slightly from 40${\AA}$to 55${\AA}$ after annealing due to grain growth and phase transformation. From capacitane-voltage measurement of Al/TiO2./p-Si structure after annealing we obtained ideal capacitance-voltage characteristics of MOS structure with dielectric constant of 16-22 in case of (100) Si and about 30- in case of 4$^{\circ}$off(100) Si but showed the higher leakage current.

  • PDF

Improvements of Information Security Level in Electronic Financial Infrastructure(By Analyzing Information Security Management Level) (전자금융기반시설 정보보호 수준강화 방안 (정보보호 관리수준 분석을 통한))

  • Park, Keun-dug;Youm, Heung-youl
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.6
    • /
    • pp.1605-1618
    • /
    • 2016
  • In recent years, security incidents - such as personal information leakage, homepage hacking, DDoS and etc. - targeting finance companies(banks, securities companies, credit card companies, insurance companies and etc.) have increased steadily. In this paper, we analyze problems of information security management level in the existing electronic financial infrastructure from perspective of compliance and information security certification system and propose improvements to enable sustainable high level of information security activities under a comprehensive management system for the financial sector characteristics using ISMS, SECU-STAR and CNIVAM system.

A Low Power and High Linearity Up Down Converter for Wireless Repeater (무선 중계기용 저전력, 고선형 Up-down Converter)

  • Hong, Nam Pyo;Kim, Kwang Jin;Jang, Jong-Eun;Chio, Young-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.433-437
    • /
    • 2015
  • We have designed and fabricated a low power and high linearity up down convertor for wireless repeaters using $0.35{\mu}m$ SiGe Bipolar CMOS technology. Repeater is composed of a wideband up/down converting mixer, programmable gain amplifiers (PGA), input buffer, LO buffer, filter driver amplifier and integer-N phase locked loop (PLL). As of the measurement results, OIP3 of the down conversion mixer and up conversion mixer are 32 dBm and 17.8 dBm, respectively. The total dynamic gain range is 31 dB with 1 dB gain step resolution. The adjacent channel leakage ratio (ACLR) is 59.9 dBc. The total power consumption is 240 mA at 3.3 V.

Error Analysis of a Sensorless Position Estimation Considering Noise for Switched Reluctance Motor (노이즈 성분을 고려한 SRM 센서리스 위치 추정의 오차 해석)

  • 김갑동;최재동;이학주;안재황;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.74-81
    • /
    • 2001
  • The sensorless scheme for Switched Reluctance Motor(SRM) drives must have the robustness and reliability because the noise and error are sensitive. These elements make electrically noisy environments due to the proximity of high current power circuits with small signal electronic circuits when SRM drives. Also, due to the leakage inductances and finite coupling capacitances, these can cause the noise on any low voltage current and voltage measurement circuit. The position estimate error occurs because the current and voltage including the noise are sued as the inputs of sensorless algorithm. In this paper the high robustness and resistance of input noise re described. The fuzzy logic based rotor estimation algorithm and the observer model are used to reduce the tolerance of input data.

  • PDF

Hall voltage measurement with respect to internal layout of REBCO coated conductors in an external magnetic field

  • Kim, Young Gon;Baek, Geonwoo;Han, Seunghak;Choi, Yojong;Kim, Junseong;Jeon, Haeryong;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.4
    • /
    • pp.48-52
    • /
    • 2019
  • Recently, many studies have been reported on the magnetoresistance and Hall effect of REBCO thin films and bulk. The voltage interferes quench detection of high-temperature superconducting magnet and generates leakage current in no insulation high-temperature superconducting coil. Therefore, in this paper, experiments on magnetoresistance and Hall effect of commercial YBCO and GdBCO tapes have been carried out. As a result, anomalous voltages expected for the magnetoresistance and Hall effect of REBCO tapes were observed and analyzed. In addition, the voltage characteristics of REBCO have been identified, and the Hall coefficient are calculated for use in high magnetic field magnet applications.

The Function of ArgE Gene in Transgenic Rice Plants

  • Guo, Jia;Seong, Eun-Soo;Cho, Joon-Hyeong;Wang, Myeong-Hyeon
    • Korean Journal of Plant Resources
    • /
    • v.20 no.6
    • /
    • pp.524-529
    • /
    • 2007
  • We carried out to study the function of ArgE in transgenic rice plants, which were confirmed by PCR analysis and hygromycin selection. Transgenic rice plants were with selectable marker gene(HPT) inserted in genome of the rice. Southern analysis with hpt probe confirmed by two restriction enzymes that copy numbers of the selectable gene was introduced into the plant genome. We displayed that the relationship between drought stress and ArgE gene with the overexpressing rice plants. From this result, we observed that the degree of leaves damage has no difference in control and transgenic lines. The total RNAs were extracted from 6 weeks-seedling in normal condition in order to examine their expression levels with ArgE-overexpressed transgenic rice. In particular, expression patterns of genes encoding enzymes involved in abiotic stress, including drought and salt stresses. OsGF14a and OsSalt were investigated by reverse transcription-PCR(RT-PCR). Expression levels of the OsSalt gene decreased significantly in transgenic rice plants compared to control plant. However, ion leakage measurement did not demonstrate any leaves damage change between control and ArgE transgenic plants exposure to mannitol treatment. These results suggest that expression of the ArgE is not involved in tolerance for drought stress in rice but may playa role of signaling networks for salt-induced genes.

DC Current Transducer Using Saturable Magnetic Cores (포화자성코어를 이용한 직류전류측정 트랜스듀서)

  • Park, Young-Tae;Jung, Jae-Kap;Gang, Jeon-Hong;Ryu, Kwon-Sang;Yu, Kwang-Min
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.138-142
    • /
    • 2004
  • Uncertainty and characteristics of the developed current sensor by means of two identically wound magnetic cores forming a ring like for measurement of a low DC current such as leakage current was described in this paper. This transducer consists of a sensor type of a current transformer, peak value detectors, a reference alternating low frequency voltage oscillator, precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC current. The resolution and sensitivity of the sensor were 0.1㎃ and 10㎷/㎃, respectively.