• Title/Summary/Keyword: Leakage Magnetic Flux

Search Result 183, Processing Time 0.035 seconds

Electromagnetic wave Shielding Materials for the Wireless Power Transfer Module in Mobile Handset (휴대단말기 무선전력 전송모듈용 전자기파 차폐소재)

  • Bae, Seok;Choi, Don-Chul;Hyun, Soon-Young;Lee, Sang Won
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.2
    • /
    • pp.68-76
    • /
    • 2013
  • Currently, wireless power transmission technology based on magnetic induction was employed in battery charger for smart phone application. The system consists of wireless power transmitter in base station and receiver in smart phone. Size and thickness of receiver was strictly limited in the newest smart phone. In order to achieve high efficiency of a tiny small wireless power receiver module, sub-millimeter thick electromagnetic wave shielding sheet having high permeability and Q was essential component. It was found that magnetic field from transmitter to receiver can be intensified by sufficient shielding cause to minimize leakage magnetic flux by those magnetic properties. This leads to high efficiency of wireless power transmission and protects crucial integrated circuit of main board from electromagnetic noise. The important soft magnetic materials were introduced and summarized for the current small-power wireless power charger and NFC application and mid-power home appliance and high-power automotive application in the near future.

Increased impedance by quench at a shield layer of HTS power cable for fault current limiting function

  • Choi, Youngjun;Kim, Dongmin;Cho, Jeonwook;Sim, Kideok;Kim, Sungkyu;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.4
    • /
    • pp.59-63
    • /
    • 2019
  • To reduce the fault current below the current capacity of a circuit breaker, researches on HTS (High Temperature Superconductor) power cables with fault current limiting (FCL) function are increasing. An FCL HTS power cable transports current with low a impedance during normal operation. Yet, it limits the fault current by an increased inductive or resistive impedance of conducting layer when quench occurs at the FCL HTS power cable by the large fault current. An inductive type FCL HTS power cable uses increased inductive impendence caused by leakage magnetic flux outside the cable core when the quench occurs at a shield layer losing the magnetic shielding effect. Therefore, it has an advantage of less resistive heating than resistive type FCL HTS power cable and temperature increase is suppressed. This paper describes an ideal circuit model for the FCL HTS power cable to investigate the effectiveness of increased inductive impedance when quench occurs at the shield layer. Then, FEM analysis is presented with a simplified model cable composed of various iron yokes to investigate the effect of the shape of yoke on the generation of the inductive impedance.

Cogging Force Verification of the Back-yoke Length of a Moving-coil-type Slotless Linear Synchronous Motor

  • Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.14 no.1
    • /
    • pp.47-51
    • /
    • 2009
  • The coreless linear synchronous motor (coreless LSM) has been widely used as a driving source of semiconductor production processes for machine speeding up, positioning accuracy and simple maintenance. However, this coreless LSM suffers the disadvantage of decreased thrust force created by the leakage of magnetic flux. With the goal of increasing the generated thrust force and decreasing the cogging force, the slot of the core part was removed and a moving-coil-type slotless LSM (moving-coil-type slotless LSM) is proposed in this paper. Although this moving-coil-type slotless LSM with a back-yoke at the primary side demonstrated an increase in the generated thrust force, it remained capable of generating the cogging force when the primary side was moved due to the position between the permanent magnet and the back-yoke. Therefore, we attempted to decrease the cogging force of the moving-coil-type slotless LSM. We found that the back-yoke length at the primary side needs to be made $0.5{\tau}$ longer than the integral multiple of the magnetic pole pitch in order to decrease the cogging force created by the moving-coil-type slotless LSM.

Development of the small NDT gauge using Magnetic Flux Leakage (자기 누설 탐상 방식을 이용한 소형 비파괴 검사기 개발)

  • Seong, Kyung-Jun;Jo, Bong-Kyun;Lee, Gen-Bo;Hong, Young-Whan;Park, Chi-Young;Park, Il-Whan;Park, Jung-Gil;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.405-407
    • /
    • 2006
  • 자기누설 탐상시스템은 자성체인 구조물에 서검사 대상 물체를 자화시켜 결함부위에서 자기 누설의 여부를 측정함으로써 구조물의 결함, 부식 등을 탐지하는 시스템이다. 본 논문에서는 소형 비파괴 검사시스템을 설계하고 제작하였다. 또한 3차원 유한요소법을 이용하여 해석하고 측정하여 결과를 비교 분석하였다.

  • PDF

Characteristics Analysis of IPM Motor Considering Magnetic Saturation of Electrical Steel (IPM 모터 철심의 포화를 고려한 특성 해석)

  • Ha, Kyung-Ho;Ahn, Young-Jun;Na, Min-Su
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1031-1032
    • /
    • 2011
  • This paper deals with the characteristics analysis of Interior Permanent Magnet Type Motor varying with magnetization curve of electrical steel interpolated with several method in the high field region. The data of magnetization curve of electrical steel given by the steel maker is not enough in order to analysis the characteristics by menas of FEM. Especially, the core in the bridge part have a severe saturation because the bridge width is narrow to reduce the flux leakage produced by the permanent magnet. This paper make the three kinds of magnetization curve by extrapolation and then the motor is analyzed by using these magnetization curve. The motor parameters are compared to explain the effects of magnetization curve.

  • PDF

Linear Pulse Motor Characteristics Analysis using Non-linear Simulation (비선형 시뮬레이션에 의한 리니어 펄스모터의 특성해석)

  • Lee, Je-Hie;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.584-587
    • /
    • 1992
  • Because linear motor directly drives linear motion, it does not need conversion equipment such as belt and gear. Especially linear pulse motor provide more precise positioning and large force of linear pulse motors. As current manufacture technic of linear pulse motor is much to be desired at home. This motor lay out to make use of computer aided design program, In this paper the experimental motor is 2-phases 4-poles hybrid pulse motor which has teeth per pole Simulation program is divided its function into 4 parts - air gap permeance analysis, permanent magnet & non-linear core operating point determine, winding configuration, leakage flux analysis. It is possible to make motor static and magnetic characteristics for this simulation program. Also, by varying input parameters of the program, experimental motor is to be compared to motor characteristics.

  • PDF

Electromagnetic Performance improvement and Rib thickness Reduction by making a hole on Interior Permanent Magnet Synchronous Motor (IPMSM의 Hole에 의한 Rib의 두께 감소와 전자기적 성능 향상)

  • Lee, Tae-Geun;Kim, Do-Jin;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.867_868
    • /
    • 2009
  • Interior permanent magnet synchronous motor [IPMSM] which has high power density is applied to motor for Hybrid electric vehicle[HEV], Electric vehicle[EV], Fuel cell electric vehicle[FCEV] and electric home appliances. In order to improve efficiency performance of IPMSM, this paper presented a study by making a hole around air barrier. Because concentrated rib stress is distributed by suitable hole, the hole can reduce rib thickness of IPM rotor. And it can help decrease PM[Permanent Magnet] leakage flux. Saliency ratio($L_q/L_d$) is also increased by magnetic circuit change. For this study, structure analysis of rotor is performed by Ansys program.

  • PDF

Precise Control of a Linear Pulse Motor Using Neural Network (신경회로망을 이용한 리니어 펄스 모터의 정밀 제어)

  • Kwon, Young-Kuk;Park, Jung-Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.11
    • /
    • pp.987-994
    • /
    • 2000
  • A Linear Pulse Motor (LPM) is a direct drive motor that has good performance in terms of accuracy, velocity and acceleration compared to the conventional rotating system with toothed belts and ball screws. However, since an LPM needs supporting devices which maintain constant air-gap and has strong nonlinearity caused by leakage magnetic flux, friction and cogging, etc., there are many difficulties in improvement on accuracy with conventional control theory. Moreover, when designing the position controller of LPM, the modeling error and load variations has not been considered. In order to compensate these components, the neural network with conventional feedback controller is introduced. This neural network of feedback error learning type changes the current commands to improve position accuracy. As a result of experiments, we observes that more accurate position control is possible compared to conventional controller.

  • PDF

Bond graph modeling and multivariable control of maglev system with a combined lift and guidance (편심배치방식 자기부상 시스템의 본드선도 모델링 및 다변수 제어)

  • 박전수;김종식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1091-1097
    • /
    • 1991
  • A logical and systematic procedure to derive a mathematical model for magnetically levitation(maglev) systems with a combined lift and guidance is developed by using and graph. First, bond graph is constructed for the energy-feeding system with magnetic leakage flux. And, the overall maglev system in which lift and guidance dynamics are coupled is modeled by using the concept of multi-port field in bond notations. Finally, the LQG/LTR control systems are designed for single-input single-output and for multi-input multi-output maglev systems. In this paper, it has been shown that the bond graph is an excellent method for modeling multi-energy domain systems such as maglev systems and the multivariable control system is required to improve the performance of the maglev system with a combined lift and guidance.

  • PDF

Analysis and Depth Estimation of Complex Defects on the Underground Gas Pipelines

  • Kim, Jong-Hwa;Kim, Min-Ho;Choi, Doo-Hyun
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.202-206
    • /
    • 2013
  • In this paper, the MFL (magnetic flux leakage) signals of complex defects on the underground gas pipeline are analyzed and their depths are estimated. Since closely-located defects (complex defects) affect each other, accelerate the progress of defection, and are finally combined to one (cluster), it's meaningful to differentiate complex defects from single defects by analyzing their characteristics. Various types of complex defects are characterized and analyzed by defining the safety distance for interference. 26 artificial defects are carved on the pipeline simulation facility (PSF) to analyze the characteristics of complex defect and demonstrate the accuracy of the proposed complex defect estimation. The proposed method shows average length error of 5.8 mm, average width error of 15.55 mm, and average depth error of 8.59%, respectively.