• Title/Summary/Keyword: Leakage Flow-rate

Search Result 264, Processing Time 0.028 seconds

Effect of heat Leak on Cycle Characteristics of Refrigerator (냉장고 사이클 특성에 미치는 열손실량의 영향)

  • 신진규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.871-879
    • /
    • 1998
  • The refrigerator consists of many components such as compressor condenser expansion valve evaporator and the cabinet which filled by urethane foam. In this paper the heat leakage of refriger-ator is measured by the new experiment method which is different from a present method, The devi-ation of the UA(overall heat transfer coefficient times area) between the simulation and experiments is about 7-8%. Using the modeling of various components of refrigeration system a performance analysos of CFC 12 and HFC 134a is performed numerically on the UA. As the results of this study according to increase the heat leakage the refrigeration load and mass flow rate of refrigerant are increased. And the increase of the mass flow rate results in the increase of the condensing and evapo-rating temperature. Therefore according to increase of the heat leakage the COP leads to increase because the increase of refrigeration capacity is larger than the increase if compressor power.

  • PDF

Numerical Analysis for Internal Leakage Flow Characteristics of Damped Bypass Valve (Damped Bypass Valve의 내부 누설 유동 특성 전산 해석)

  • Lee, Seawook;Kim, Daehyun;Kim, Sangbeom;Park, Sangjoon;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • A numerical analysis for the internal flow was carried out in order to analyze the leakage flow characteristics inside the damped bypass valve. This research has found that the valve characteristics became stable at above a specific temperature. Very small amount of leakage flow was occurred. But there was no effect in temperature. The more temperature fell, the more maximum pressure rate was increased.

An Experimental Study for Performance Evaluation of a Ceramic Heat Exchanger (세라믹 열교환기의 성능평가를 위한 실험적 연구)

  • Choi, Hyun-Soo;Shin, Dong-Hoon
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.1
    • /
    • pp.46-51
    • /
    • 2011
  • Exhaust gas of an industrial furnace used at such as metallurgy or ceramic manufacturing usually contains thermal energy with high temperature which can be recycled by heat exchanger. However, when the temperature of the exhaust gas is high such as more than $1,000^{\circ}C$, ordinary metallic heat exchanger cannot fully recover the heat due to the limitation of operating temperature depending on the material property. In the present study, a compact ceramic heat exchanger of cross flow type is introduced and evaluated by heat exchange rate and operating temperature. The ceramic heat exchanger can endure the gas temperature more than $1,300^{\circ}C$, and its volumetric heat exchanging rate exceeds 1 MW/$m^3$. The experimental data is also compared with the previous numerical result which shows reasonable agreement. Meanwhile, the gas leakage rate is measured to be about 3~4%, and heat loss to environmental air is about 23~26% of the fuel energy.

An Analytic and Experimental Study on the Performance Characteristic of the Rotary Compressor (로타리 압축기 성능특성에 관한 해석 및 실험)

  • 최득관;김경천;차강욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.497-504
    • /
    • 2001
  • A study to improve the accuracy of a map-based compressor model with experiment was performed. Corrections on the effects of suction gas superheat and heat leakage from a compressor shell are required to apply the compressor amp model based on the empirical performance data(map) of compressor manufacturers to the actual system. So experiments to assess the effects of superheat and hat leakage were performed and the corrected equations were made. Compressors and refrigerant used in the experiment were the high pressure type rotary compressor and R-22, experiments were performed by compressor calorimeter. From the experiment, a volumetric efficiency correction factor$(F_ν)$ showed the value of 0.77, slightly higher than 0.75 proposed by Dabiri and Rice for low pressure type reciprocating compressor, and the heat leakage from the compressor shell turned out to be a factor that influenced the discharged mass flow rate. The relation between heat leakage of compressor shell and the variation of discharged mass flow rate from compressor was considered in compressor map modeling as an empirical function. With this function, the prediction accuracy of compressor model in system conditions was improved.

  • PDF

Experimental and Numerical Study on the Performance Characteristics of an Open Channel Type Regenerative Pump (개수로형 재생펌프의 성능특성에 관한 실험적 및 수치해석적 연구)

  • Shin, Dong-Yun;Choi, Chang-Ho;Hong, Soon-Sam;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.5
    • /
    • pp.7-14
    • /
    • 2008
  • Open channel type regenerative pump has been used in various industrial fields. It generates high pressure with low flow rate. However, it has low efficiency because of its complex flow pattern, We studied performance experiments and 3D numerical flow analysis of a regenerative pump. Through the numerical analysis, we could get the internal flow pattern and profile of a regenerative pump. Also, we examined leakage flow effects due to the gap between casing and impeller and stripper clearance. For the numerical analysis verification, we performed experiments and they had similar tendency at the design point.

Experimental Study on Flows within an Unshrouded Centrifugal Impeller Passage(II)-on the Influence of Flow Rate- (개방형 원심회전차의 내부유동장에 관한 실험적 연구(2)-유량에 따른 영향-)

  • Kim, Seong-Won;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3251-3261
    • /
    • 1996
  • Flows were measured in an unshrouded centrifugal impeller. By using a single slanted hot-wire probe and a Kiel probe mounted on the impeller hub disk, the 3-D relative velocities and the rotary stagnation pressures were measured in seven circumferential planes between the inlet and outlet of the impeller rotating at 700 rpm, which diameter is 0.39 meter, and the static pressures and the slip factor at the impeller outlet were estimated from the measured values. Measurements were made for three flow rates corresponding to zero incidence and two others with the greater and the smaller one than zero. From the measured data in these flow rates, the followings were investigated in the impeller passage, the variation of the primary and secondary flows, the leakage flows, the wake's position and its size, the static pressure rise and the loss production mechanism. Furthermore the static pressure and the slip factor were compared with the results of inviscid Quasi-3D calculation.

A Study on the Simulation of Leak Flow-rate Using Isothermal Chamber (등온화용기를 이용한 누설유량 시뮬레이션에 관한 연구)

  • Ji, S.W.;Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.71-75
    • /
    • 2010
  • Leak detection technology is a challenging research until nowadays, because it has wide and various applications in industry. Furthermore pneumatic component reliability test based on ISO requires air leakage measurement. The conventional measurement methods need a complex operation and the calibration of leak detector. Tracing the history of our study, we proposed a new method for measurement of leak flow rate using isothermal chamber. In this study, propose a simulation model of isothermal chamber by infinitesimal flow -rate, such as a leak flow-rate. The effectiveness of the proposed simulation model is proved by simulation and experimental results. Base on the comparison results, proposed simulation model is good agreement with experimental results.

Numerical Study on the Variation of Axial Thrust of Rotating Disc with Pump-Out Vane (POV가 부착된 회전 원판의 축추력 변화에 관한 연구)

  • Seong Seong-Mo;Kang Shin-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.3 s.246
    • /
    • pp.230-237
    • /
    • 2006
  • Flows in the cavity with pump out vane are calculated using the CFX-Tascflow CFD code. flow calculations are performed for different values of vane height, numbers, leakage flow rate, and rotational speed. The flow is very complex and three dimensional with strong vortex and leakage flow over the vane. The variations of pressure coefficient and K-factor with these parameters and resulting effects on the thrust and torque are studied. The present study contributes to showing the capability of flow simulation of back cavity with pump-out vane. The calculated results are good enough to be used back cavity design.

Design and Fabrication of a Microflow Rate Controller for Medical Injection (주사용 미세유량 조절기 설계와 제작)

  • Kim, Byoung-Jae;Lee, Sang-Bin;Shin, Bo-Sung;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.154-159
    • /
    • 2004
  • A new microflow rate controller for medical injection was developed and evaluated. The flow rate was controlled by changing the friction depth as well as the friction length of the micro-channel. A precise micro-fabrication of the micro-channel was requested for an accurate flow control. The friction depth was inversely proportional to the friction length, which gives a linear flow control to the channel length. The channel groove was fabricated with a plastic material. A rubber containing silicone oil was covered over the groove, which satisfies both lubrication and leakage prevention. The flow controller was validated by performing the numerical simulation and experiment. A good agreement was shown between computation and experiment.

Leakage and Rotordynamic Analysis of Damper Floating Ring Seal with Round­Hole Surfaces in the High Pressure Turbo Pump (원형 단면 구멍 표면을 갖는 댐퍼 후로팅 링 실의 누설량 및 회전체 동역학적 특성 해석)

  • 하태웅;이용복;김창호
    • Tribology and Lubricants
    • /
    • v.19 no.6
    • /
    • pp.349-356
    • /
    • 2003
  • A damper floating ring seal with round hole pattern surfaces is suggested for better leakage control. The flat plate test of the round hole pattern surfaces has been performed to yield an empirical friction factor model. The exact predictions of the lock­up position of the damper floating ring, the leakage performance, and the rotordynamic coefficients of the seal are necessary to evaluate the rotordynamic performance of the turbo pump unit. The governing equations including the empirical friction factor model for round hole pattern surfaces are solved by the Fast Fourier Transform method. The lock­up position, leakage flow rate, and rotordynamic coefficients are evaluated according to the geometric parameters of the damper floating ring seal. Theoretical results show that the damper floating ring seals yield less leakage and better rotordynamic stability than the floating ring seal with a smooth surface.