Abstract
Open channel type regenerative pump has been used in various industrial fields. It generates high pressure with low flow rate. However, it has low efficiency because of its complex flow pattern, We studied performance experiments and 3D numerical flow analysis of a regenerative pump. Through the numerical analysis, we could get the internal flow pattern and profile of a regenerative pump. Also, we examined leakage flow effects due to the gap between casing and impeller and stripper clearance. For the numerical analysis verification, we performed experiments and they had similar tendency at the design point.