• 제목/요약/키워드: Leakage Error

검색결과 167건 처리시간 0.062초

CFD를 사용한 복잡한 형상을 갖는 래버린스 실의 누설량 예측 (Prediction of Combination-Type-Staggered-Labyrinth Seal Leakage Using CFD)

  • 하태웅
    • Tribology and Lubricants
    • /
    • 제22권2호
    • /
    • pp.66-72
    • /
    • 2006
  • Leakage reduction through annular type labyrinth seals of steam turbine is necessary for enhancing their efficiency and the precise prediction method of seal leakage is needed. In this study, numerical analysis for leakage prediction of the combination-type-staggered-labyrinth seal has been carried out using FLUENT 6 which is commercial CFD (Computational Fluid Dynamics) code based on FVM (Finite Volume Method) and SIMPLE algorism. The present CFD results are verified with the theoretical analysis based on Bulk-flow concept which has been mainly used in predicting seal leakage. Comparing with the result of Bulk-flow model analysis, the leakage result of CFD analysis shows good agreement within 7.1% error.

잡음영향의 저감을 위한 두 디지털 필터들의 사용에 의한 DFT 기반의 계통주파수 추정 (DFT-based Power System Frequency Estimation using Two Digital Filters for Noise Effect Reduction)

  • 황진권
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.891-897
    • /
    • 2013
  • The power system frequency plays an important role in monitoring and controlling the power system. The frequency can be measured through discrete Fourier transform (DFT) coefficients of its positive fundamental frequency. The accuracy of the frequency estimate is severely affected by noise in the power system signal and the leakage effect of the negative fundamental frequency in DFT. This paper proposes a DFT-based frequency estimation algorithm to cope with the noise as well as the leakage effect. In this algorithm, two suitable digital filters are introduced to reduce efficiently frequency estimate error due to the noise. These filters are designed to use a digital bandpass filter and a second-degree integrator. The effectiveness of the proposed algorithm in reduction of frequency estimate error is verified through simulations on noise, harmonics and frequency deviation.

반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템 (Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement)

  • 전정채;유재근
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

누설량 저감을 위한 래버린스 실의 설계개선 및 해석 (Leakage Analysis and Design Modification of the Combination-Type-Staggered-Labyrinth Seal)

  • 하태웅
    • Tribology and Lubricants
    • /
    • 제23권2호
    • /
    • pp.43-48
    • /
    • 2007
  • Leakage reduction through annular type labyrinth seals of steam turbine is necessary for enhancing their efficiency. In this study, modified geometry of the original combination-type-staggered-labyrinth seal has been suggested and numerical analysis for leakage prediction has been carried out for the modified-combination-type-staggered-labyrinth seal both based on bulk-flow model and using the CFD code FLUENT. The theoretical analysis based on bulk-flow model yields leakage reduction of the modified combination type staggered labyrinth seal by about 11%. Comparing with the result of Bulk-flow model analysis, the leakage result of CFD analysis shows reasonable agreement within 9.8% error.

모델링과 검증에 의한 파이프 라인 시스템의 유출 탐지 (Leakage detection of pipeline system based on modeling and identification)

  • 이주형;이광순;송형근
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.905-910
    • /
    • 1991
  • This paper presets a leakage detection method based on modeling the leakage in pipeline systems. For gas pipeline systems, a method based on the state space model is suggested. For liquid pipeline systems, an experiment based on the static model equation was performed. In the experiment, it was possible to detect the leak and to diagnosis the leak situation within the error of .+-.3%.

  • PDF

Magnetic Flux Leakage (MFL) based Defect Characterization of Steam Generator Tubes using Artificial Neural Networks

  • Daniel, Jackson;Abudhahir, A.;Paulin, J. Janet
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.34-42
    • /
    • 2017
  • Material defects in the Steam Generator Tubes (SGT) of sodium cooled fast breeder reactor (PFBR) can lead to leakage of water into sodium. The water and sodium reaction will lead to major accidents. Therefore, the examination of steam generator tubes for the early detection of defects is an important requirement for safety and economic considerations. In this work, the Magnetic Flux Leakage (MFL) based Non Destructive Testing (NDT) technique is used to perform the defect detection process. The rectangular notch defects on the outer surface of steam generator tubes are modeled using COMSOL multiphysics 4.3a software. The obtained MFL images are de-noised to improve the integrity of flaw related information. Grey Level Co-occurrence Matrix (GLCM) features are extracted from MFL images and taken as input parameter to train the neural network. A comparative study on characterization have been carried out using feed-forward back propagation (FFBP) and cascade-forward back propagation (CFBP) algorithms. The results of both algorithms are evaluated with Mean Square Error (MSE) as a prediction performance measure. The average percentage error for length, depth and width are also computed. The result shows that the feed-forward back propagation network model performs better in characterizing the defects.

직교 동기 검파방식의 열화특성에 대한 해석 (Error Analysis of Quadrature Coherent Detector System)

  • 백주기;이승대;이병선;진연강
    • 전자공학회논문지T
    • /
    • 제35T권3호
    • /
    • pp.113-119
    • /
    • 1998
  • 본 논문에서는 직교 동기 검파기를 모델링하여 수치해석을 통한 채널의 이득/위상 불균형등을 고려했을 때와 국부발진누설까지 고려했을 때의 에러측대파 레벨과 신호대 잡음손실의 특성을 알아보았다. 수치해석 결과, 채널 이득/위상 불균형(0.8[㏈]/5[dog])을 고려했을 때와 국부발진누설까지 고려했을 때의 에러측대파 레벨과 신호대 잡음손실은 각각 (-21.322[㏈], -0.0071[㏈]), (-11.6839[㏈], -0.0059[㏈])의 특성을 보였다.

  • PDF

누설전류측정에 의한 피뢰기 열화진단에 있어 전원고조파의 영향 (Influence of Harmonics in Power System Voltage on Arrester Deterioration Diagnostics by Leakage Current Measurement)

  • 길경석;한주섭;주문노
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권1호
    • /
    • pp.42-46
    • /
    • 2003
  • Arresters are deteriorated by overvoltages or impulse currents, and the resistive leakage current of arresters increases as the deterioration of the arrester progresses, showing an increase in the 3$^{rd}$ harmonic component of the leakage current. In this reason, arrester diagnostic techniques based on the 3$^{rd}$ harmonic leakage current as a reference parameter of deterioration are widely used. The technique, however, includes an error due to the harmonics of power system voltage. Therefore, the influence of the harmonics on arrester diagnostics should be considered. In this paper, we designed a PSpice ZnO arrester model to simulate the influence of the voltage harmonics described above. A pure sinusoidal voltage and its the 3r harmonic voltage were applied to the model, and the leakage current components were analyzed. From the simulation results, it is confirmed that the peak value of resistive leakage current depends not only on the phase of the 3$^{rd}$ harmonic voltage but also on the magnitude of it. Consequently, the errors caused 1)y the harmonic voltage could be minimized by correcting the magnitude of leakage current upon analyzing the harmonics.cs.

Analysis of the Effect of Coherence Bandwidth on Leakage Suppression Methods for OFDM Channel Estimation

  • Zhao, Junhui;Rong, Ran;Oh, Chang-Heon;Seo, Jeongwook
    • Journal of information and communication convergence engineering
    • /
    • 제12권4호
    • /
    • pp.221-227
    • /
    • 2014
  • In this paper, we analyze the effect of the coherence bandwidth of wireless channels on leakage suppression methods for discrete Fourier transform (DFT)-based channel estimation in orthogonal frequency division multiplexing (OFDM) systems. Virtual carriers in an OFDM symbol cause orthogonality loss in DFT-based channel estimation, which is referred to as the leakage problem. In order to solve the leakage problem, optimal and suboptimal methods have already been proposed. However, according to our analysis, the performance of these methods highly depends on the coherence bandwidth of wireless channels. If some of the estimated channel frequency responses are placed outside the coherence bandwidth, a channel estimation error occurs and the entire performance worsens in spite of a high signal-to-noise ratio.

A New method for the Calculation of Leakage Reactance in Power Transformers

  • Dawood, Kamran;Alboyaci, Bora;Cinar, Mehmet Aytac;Sonmez, Olus
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1883-1890
    • /
    • 2017
  • Transformers are one of the most precious elements of the electric power system. Stability and reliability of the electric power network mainly depend on the working of the transformer. Leakage reactance of the transformer is one of the important factors and accurate calculation of the leakage reactance is necessary for the transformer designers and electric distributors. Leakage reactance of the transformer depends on the geometry of the transformer. There are many different methods for the calculations of the leakage reactance however mostly are usable when the axial heights of the high voltage and low voltage windings are equal. When the axial heights of high voltage and low voltage windings are asymmetric most of the analytical methods are not reliable. In this study, a new analytical method is introduced for the calculation of the leakage reactance. Fourteen different transformers are investigated in this study and four of them are presented in this paper. The results of the new analytical method are compared with the experimental results. Other analytical and numerical methods are also compared with this new method. Results show that this method is more reliable and accurate as compared to the other analytical methods. The maximum relative error between short-circuit test and proposed method for these fourteen transformers was less than 2.8%.