• Title/Summary/Keyword: Leakage Error

Search Result 167, Processing Time 0.028 seconds

An Enhancement of Transfer Function Synthesis by Improving the Leakage Error of FRF (FRF 누설오차 개선에 의한 전달함수 합성법의 향상)

  • Ahn, Se-Jin;Jeong, Weui-Bong;Kim, Seung-Yup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.517-522
    • /
    • 2002
  • The frequency response function(FRF) of each substructure is used for the transfer function synthesis method(TFS). The dynamic characteristics of the full system are obtained by synthesizing FRFs of each substructure. The validation of TFS depends on accuracy for FRF of each substructure. Impact hammer testing is widely used to obtain the modal characteristics of structures. However, the FRF obtained from impact hammer testing contains several errors, such as finite record length error and leakage error of which characteristic depends on data acquisition time which we call record length. In this paper, a method to remove these errors is proposed so as to enhance results of TFS. Numerical examples show that the FRF of full structure can be predicted exactly by the method proposed in this paper.

  • PDF

Detecting steam leakage by using correction of camera vibrating (카메라 흔들림 보정을 통한 증기 누설 탐지)

  • Choi, Young-Chul;Yoon, Chan-Hoon;Kim, Jin-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.394-398
    • /
    • 2014
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. Recently, the research detecting the steam leakage by using camera image is introduced. However, this method has a disadvantage. If a camera oscillates, it cannot detect a steam leakage exactly. In this paper, the technique that reduces the error due to a camera shaking is proposed. To verify the proposed method, we have performed the experiments for the oil leakage experiments. The results show that the technique can calibrate the error due to camera shaking.

  • PDF

Joint Transmitter and Receiver Design based on Effective-leakage in Multi-user MIMO systems (다중사용자 다중안테나 시스템에서 effective-leakage 기반 송신기와 수신기 결합 설계)

  • Seo, Dong-Joon;Lee, Jae-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.191-192
    • /
    • 2008
  • We give new definition of the effective-leakage and the signal to effective-leakage plus noise ratio (SELNR) to consider receiver combining motivated by the leakage. We propose a method to find jointly beamforming vector and combining vector for the two linear receivers (maximal ratio combining (MRC) receiver and minimum mean square error (MMSE) receiver) based on the SELNR.

  • PDF

A New Method for Resistive Leakage Current Measurement (새로운 저항성 누전전류 측정 방법)

  • Ham, Seung-Jin;Hahn, Song-Yop;Koh, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1397-1404
    • /
    • 2007
  • It is important to measure the resistive component separately from the total leakage current at power distribution line. It is because electric disasters such as electric shock and fire are caused mainly by the resistive component of the total leakage current. In this paper, a new theory for measuring the resistive component separately from the total leakage current is suggested, and is embodied to an actual circuit using operational amplifiers, analog switch and R-C low pass filter. Through experiments for various cases containing both the resistive and capacitive leakage currents, the suggested algorithm is confirmed to be able to measure the resistive leakage current within 4.1% of error even when the capacitive leakage current is much bigger than the resistive one. The suggested method is expected to lower the total cost because it can be realized using simple and cheap devices, and implies the measuring time can be possibly reduced because the resistive leakage current is computed exactly from the signals during only a half period of power voltage.

The Effect of Transformer Leakage Inductance on the Steady State Performance of Push-pull based Converter with Continuous Current

  • Chen, Qian;Zheng, Trillion Q.;Li, Yan;Shao, Tiancong
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.349-361
    • /
    • 2013
  • As a result of the advantages such as high efficiency, continuous current and high stability margin, push-pull converter with continuous current (PPCWCC) is competitive for battery discharge regulator (BDR) which plays an important role in power conditioning unit (PCU). Leakage inductance yields current spike in low-ripple current of PPCWCCs. The operating modes are added due to leakage inductance. Therefore the steady state performance is affected, which is embodied in the spike of low-ripple current. PPCWCCs which are suitable for BDR can be separated into three types by current spike characteristics. Three representative topologies IIs1, IIcb2 and Is3 are analyzed in order to investigate the factors on the magnitude and duration of spike. Equivalent current sampling method (ECSM) which eliminates the sampling time delay and achieves excellent dynamic performance is adopted to prevent the spike disturbance on current sampling. However, ECSM reduces the sampling accuracy and telemetry accuracy due to neglecting the spike. In this paper, ECSM used in PPCWCCs is summarized. The current sampling error is analyzed in quality and quantity, which provides the foundation for offsetting and enhancing the telemetry accuracy. Finally, current sampling error rate of three topologies is compared by experiment results, which verify the theoretical analysis.

An Enhancement of Multi-Dof Frequency Response Spectrum From Impact Hammer Testing (충격햄머 실험에서 다자유도 주파수 응답스팩트럼의 개선)

  • Ahn, Se-Jin;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.623-629
    • /
    • 2002
  • The spectrum of impulse response signal from an impulse hammer testing is widely used to obtain frequency response function(FRF) of the structure. However the FRFs obtained from impact hammer testing have not only leakage errors but also finite record length errors when the record length for the signal processing is not sufficiently long. The errors cannot be removed with the conventional signal analyzer which treats the signals as if they are always steady and periodic. Since the response signals generated by the impact hammer are transient and have damping, they are undoubtedly non-periodic. It is inevitable that the signals be acquired for limited recording time, which causes the finite record length error and the leakage error. In this paper, the errors in the frequency response function of multi degree of freedom system are formulated theoretically. And the method to remove these errors is also suggested. This method is based on the optimization technique. A numerical example of 3-dof model shows the validity of the proposed method.

  • PDF

The Improvement of Multi-dof Impulse Response Spectrum by Using Optimization Technique (최적화 기법을 이용한 다자유도 충격응답스펙트럼의 오차 개선)

  • 안세진;정의봉
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.10
    • /
    • pp.792-798
    • /
    • 2002
  • The spectrum of impulse response signal from an impulse hammer testing is widely used to obtain frequency response function (FRF) of the structure. However the FRFs obtained from impact hammer testing have not only leakage errors but also finite record length errors when the record length for the signal processing is not sufficiently long. The errors cannot be removed with the conventional signal analyzer which treats the signals as if they are always steady and periodic. Since the response signals generated by the impact hammer are transient and have damping, they are undoubtedly non-periodic. It is inevitable that the signals be acquired for limited recording time, which causes the finite record length error and the leakage error. In this paper, the errors in the frequency response function of multi degree of freedom system are formulated theoretically. And the method to remove these errors is also suggested. This method is based on the optimization technique. A numerical example of 3-dof model shows the validity of the proposed method.

Dipole Model to Predict the Rectangular Defect on Ferromagnetic Pipe

  • Suresh, V.;Abudhair, A.
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.437-441
    • /
    • 2016
  • Dipole model based analytical expression is proposed to estimate the length and depth of the rectangular defect on ferromagnetic pipe. Among the three leakage profiles of Magnetic Flux Leakage (MFL), radial and axial leakage profiles are considered in this work. Permeability variation of the specimen is ignored by considering the flux density as close to saturation level of the inspected specimen. Comparing the profile of both the components, radial leakage profile furnishes the better estimation of defect parameter. This is evident from the results of error percentage of length and depth of the defect. Normalized pattern of the proposed analytical model radial leakage profile is good agreement with the experimentally obtained profile support the performance of proposed expression.

The New Residual Current Protective Devices Operating by Resistive Leakage Current (저항성 누전전류에 의하여 동작하는 새로운 누전차단기)

  • Ham, Seung-Jin;Hahn, Song-Yop;Koh, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.198-207
    • /
    • 2008
  • The conventional Residual Current Protective Devices(RCD, or earth leakage circuit breaker, ELB) operates depending on the total leakage current which is the vector-sum of resistive and capacitive components of a leakage current. However, the electric disaster such as electric shock or fire is mainly caused by the resistive component. Therefore, in this view point, the RCD is more realistic when it operates by the resistive component of the leakage current. In this paper, a new algorithm for measuring the resistive leakage current from the total leakage current is suggested, and is realized to an actual circuit. According to the suggested algorithm, the resistive component of the leakage current can be found by integrating the total leakage current over only a half cycle of the line voltage, and it is realized by using analog switches and resettable integrators. It is confirmed through experiments that the suggested algorithm detects, within maximum average error of 6.74%, the resistive leakage current from the total leakage current, and the RCD employing the suggested algorithm brakes the circuit within the regular interrupt time(30msec).

Improved Leakage Signal Blocking Methods for Two Channel Generalized Sidelobe Canceller

  • Kim, Ki-Hyeon;Ko, Han-Seok
    • Speech Sciences
    • /
    • v.13 no.1
    • /
    • pp.117-128
    • /
    • 2006
  • The two-channel Generalized Sidelobe Canceller (GSC) scheme suffers from the presence of leakage signal in the reference channel. The leakage signal is caused by the dissimilar impulse responses between microphones, and different paths from speech source to microphones. Such leakage is detrimental to speech enhancement of the GSC since the desired reference signal becomes corrupted. In order to suppress the signal leakage, two matrix injection methods are proposed. In the first method, a simple gain compensation matrix is used. In the second, a projection matrix for reducing the error between the actual and the ideal primary and reference signals, is used. This paper describes the performance degradation resulting from leakage, and proposes effective methods to resolve the problem. Representative experiments were conducted to demonstrate the effectiveness of the proposed methods on recorded speech and noise in an actual automobile environment.

  • PDF