• 제목/요약/키워드: Leakage Defects

검색결과 177건 처리시간 0.022초

콘크리트 수조에 적용되는 폴리우레아 방수방식 공법의 내구성 향상을 위한 시험 평가 방법에 관한 연구 (A Study on Performance Test Method of Polyurea Waterproofing System Applied to the Concrete Water Tank)

  • 도광구;송제영;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.12-13
    • /
    • 2020
  • Construction projects and buildings are becoming taller and larger, and the size of water tanks of production facilities and high-rise buildings is also gradually increasing. Most large water tanks apply a waterproofing layer to the water tank type concrete structure. The application of polyurea coating materials, which are excellent in water resistance, chemical resistance, physical performance, rapid hardening, and workability is gradually increasing as waterproofing and anticorrosion layer for water tank. As a result, defects such as water leakage and damage to the waterproofing layer are continuously occurring, causing production disruption, setback to users. Therefore, it is required to review suitability through performance verification of the waterproofing and anticorrosion system.

  • PDF

ZnO-Co3O4-Cr2O3-La2O3 세라믹스의 결함과 입계 특성에 미치는 CaCO3의 영향 (Effects of CaCO3 on the Defects and Grain Boundary Properties of ZnO-Co3O4-Cr2O3-La2O3 Ceramics)

  • 홍연우;하만진;백종후;조정호;정영훈;윤지선
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.307-312
    • /
    • 2018
  • Liquid phases in ZnO varistors cause more complex phase development and microstructure, which makes the control of electrical properties and reliability more difficult. Therefore, we have investigated 2 mol% $CaCO_3$ doped $ZnO-Co_3O_4-Cr_2O_3-La_2O_3$ (ZCCLCa) bulk ceramics as one of the compositions without liquid phase sintering additive. The results were as follows: when $CaCO_3$ is added to ZCCLCa ($644{\Omega}cm$) acting as a simple ohmic resistor, CaO does not form a secondary phase with ZnO but is mostly distributed in the grain boundary and has excellent varistor characteristics (high nonlinear coefficient ${\alpha}=78$, low leakage current of $0.06{\mu}A/cm^2$, and high insulation resistance of $1{\times}10^{11}{\Omega}cm$). The main defects $Zn_i^{{\cdot}{\cdot}}$ (AS: 0.16 eV, IS & MS: 0.20 eV) and $V_o^{\bullet}$ (AS: 0.29 eV, IS & MS: 0.37 eV) were found, and the grain boundaries had 1.1 eV with electrically single grain boundary. The resistance of each defect and grain boundary decreases exponentially with increasing the measurement temperature. However, the capacitance (0.2 nF) of the grain boundary was ~1/10 lower than that of the two defects (~3.8 nF, ~2.2 nF) and showed a tendency to decrease as the measurement temperature increased. Therefore, ZCCLCa varistors have high sintering temperature of $1,200^{\circ}C$ due to lack of liquid phase additives, but excellent varistor characteristics are exhibited, which means ZCCLCa is a good candidate for realizing chip type or disc type commercial varistor products with excellent performance.

모듈러 공사시방서 개선방안에 관한 연구 - 방수 및 기계설비공사의 기술방안 개선을 중심으로 - (A Study on Improvement of Modular Specifications - Focused on technical specifying method in waterproof and mechanical works -)

  • 윤종식;신동우;차희성;김경래
    • 한국건설관리학회논문집
    • /
    • 제18권3호
    • /
    • pp.33-41
    • /
    • 2017
  • 모듈러 시방서는 모듈제작, 운송, 설치에 필요한 요구사항을 기술하는 계약문서이다. 그러나 기존 모듈러 시방서의 문제점은 모듈러 공사에서 요구하는 성능수준을 보장해주지 못하고 공사별 특성을 배제한 채 건축공사 표준시방서의 내용을 그대로 차용하고 있다는 것이다. 본 연구에서는 모듈러 건축의 품질개선 방안으로 모듈러 특성에 적합한 공사시방서를 제안하였다. 연구의 범위는 하자발생이 높은 방수공사 및 기계설비공사에 한하여 진행하였다. 본 연구에서 제안하는 모듈러 시방서 개선방안은, 1) 마스터 포맷에 따른 descriptive형식의 서술, 2)누수점검 및 검사 항목 반영, 3) 모듈러 특성을 고려한 시방서 내용 작성이다. 개선안을 전문가 면담을 통해 검증하였으며 이와 같은 개선방안이 모듈러 공사시방서를 보완하여 향후 모듈러 건축의 품질향상을 가져올 수 있을 것으로 평가하였다. 본 연구에서 제안하는 시방서 개선안은 전체 공사시방서 작성의 가이드가 될 수 있으며, 이를 통해 모듈러 건축의 하자발생률을 낮추는데 큰 영향을 미칠 수 있을 것이다.

강자성체 배관 탐상용 RFECT System의 설계에 관한 연구 (A Study on the Design of RFECT System for Ferromagnetic Pipelines)

  • 이유기;김희민;박관수
    • 한국자기학회지
    • /
    • 제24권6호
    • /
    • pp.171-178
    • /
    • 2014
  • 전자기를 이용하여 배관의 비파괴검사를 적용하는 방법 중 하나인 Remote Field Eddy Current Testing (RFECT)는 큰 마찰력이 발생하고 잔류자화성분이 남는 Magnetic Flux Leakage (MFL) 방식과 외벽의 결함을 측정하는데 곤란한 일반 Eddy Current Testing (ECT) 방식의 단점들을 보완할 수 있는 기법으로 50여 년 전부터 다양한 기관에서 연구되어왔다. 그러나 배관 내에서 발생하는 와전류와 자기장에 대한 연구와 RFECT Exciter Coil의 설계에 대한 논의가 부족한 실정이다. 본 논문에서는 유한요소법을 이용한 전자기 해석을 통해 배관 내에서 발생하는 와전류와 자기장의 분포를 확인하고 변수 변화에 따른 영향을 분석하였다. 또한 Exciter Coil에 대한 최적 설계 알고리즘을 제시하고, 결함 형상과 기타 변수 변화가 결함신호에 미치는 영향을 확인하였다.

ALD법으로 성장한 HfO2 박막의 열처리에 따른 특성변화 (Effects of Post-Annealing on Properties of HfO2 Films Grown by ALD)

  • 이재웅;함문호;맹완주;김형준;명재민
    • 한국재료학회지
    • /
    • 제17권2호
    • /
    • pp.96-99
    • /
    • 2007
  • The effects of post-annealing of high-k $HfO_2$ thin films grown by atomic layer deposition method were investigated by the annealing treatments of $400-600^{\circ}C$. $Pt/HfO_2/p-Si\;MOS$ capacitor structures were fabricated, and then the capacitance-voltage and current-voltage characteristics were measured to analyze the electrical characteristics of dielectric layers. The X-ray diffraction analyses revealed that the $500^{\circ}C-annealed\;HfO_2$ film remained to be amorphous, and the $600^{\circ}C-annealed\;HfO_2$ film was crystallized. The annealing treatment at $500^{\circ}C$ resulted in the highest capacitance and the lowest leakage current due to the reduction of defects in the $HfO_2$ films and non-crystallization. Our results suggest that post-annealing treatments are a critical factor in improving the characteristics of gate dielectric layer.

가스 파이프라인 상의 압력 부식에 의한 흠집 검사를 위한 원격 와전류 탐상 기술 (Remote Field Eddy Current Testing for Detection of Stress Corrosion Cracks in Gas Transmission Pipelines)

  • 김대원
    • 한국자기학회지
    • /
    • 제16권6호
    • /
    • pp.305-308
    • /
    • 2006
  • Magnetic flux leakage(MFL) 신호를 이용하여 비파괴 검사 신호를 획득하는데 주로 사용하는 감지기 또는 금속 덩어리를 의미하는 pig 이용 기술은 일반적으로 천연 가스 전송에 사용되는 강철 파이프라인 상의 대량 부식 흔적을 감지하는데 널리 이용 되어지고 있다. 이를 대체할 수 있는 비파괴 검사 기술의 양상에 대하여 소개 하자면, 지하에 매설된 가스 파이프라인의 바깥 면에 가로축을 따라 난, 부식에 의한 결함에 일반적으로 동반하는 '압력에 의한 부식 흠집(Stress Corrosion Crack : SCC)'을 탐지하는 기술이 있다. 본 논문은 가스 파이프라인 상의 가능성 있는 SCC 검출 장치로서 탐촉자의 원거리에 형성된 다상 회전 전자장 활용 기술에 대하여 논하고 있다. Pig 원형에 대한 묘사와 비파괴 신호 검사용 탐촉자에 대한 설명이 덧붙여져 있으며 결함 검지장치의 유한 요소 모델링과 연관한 부분에 관하여도 발전적으로 논하였다. 테스트 용 pig를 이용한 초기 실험 결과는 본 논문에서 보이고 있는 비파괴 검사 양식이 가스 파이프 라인의 가로축을 따라 발생한 결함에 매우 민감하게 반응하고 있음을 보이고 있다.

Erosion behavior according to location of conduit cracks in agricultural reservoir

  • Ryu, Jung-Hyun;Heo, Joon;Shim, Jae-Woong;Kim, Cheol-Han;Yun, Bora;Lee, Yong-Hak;Lee, Dal-Won
    • 농업과학연구
    • /
    • 제47권4호
    • /
    • pp.1159-1168
    • /
    • 2020
  • The conduits of agricultural reservoirs undergo deterioration over a considerable period of time and this is highly likely to cause structural problems such as cracks. It is therefore important to consider the effects of structural defects on the body from the viewpoint of stability and maintenance of the embankment. In this study, basic data on the effects of the crack location on the stability of the embankment is obtained by identifying, comparing, and analyzing the erosion characteristics and pore water pressure behavior through a large-scale model experiment that involves classifying the location of the conduit cracks. From the results of the experiment, it was confirmed that when a crack occurred, the amount of leakage increased as the location of the crack portion was closer to the water level, and the internal erosion phenomenon accelerated, thereby increasing the possibility of piping. It was also found that an upstream conduit crack affects the erosion and water pressure change of the central and downstream conduit of the embankment, and the conduit crack has a very large effect on the pore water pressure despite the low upstream water level. Therefore, the seepage behavior of the embankment for each conduit crack identified in this study is considered to be useful basic data for preparing a repair and reinforcement plan according to the crack location in the future.

The hybrid perventricular closure of apical muscular ventricular septal defect with Amplatzer duct occluder

  • Kim, Soo Jin;Huh, June;Song, Jin Young;Yang, Ji-Hyuk;Jun, Tae-Gook;Kang, I-Seok
    • Clinical and Experimental Pediatrics
    • /
    • 제56권4호
    • /
    • pp.176-181
    • /
    • 2013
  • Purpose: Apical muscular ventricular septal defects (MVSDs), especially in small infants, can be difficult to manage using surgical and percutaneous closure. An intraoperative perventricular procedure is a good option for closing apical MVSDs in small children with or without associated cardiac anomalies. We evaluated the results of hybrid perventricular closure of apical MVSDs performed using an Amplatzer duct occluder (ADO). Methods: We retrospectively reviewed the medical records of 5 patients who underwent hybrid perventricular closure of MVSDs with ADOs, from March 2006 to May 2011. The median patient age at the time of the procedure was 12 months (range, 25 days to 25 months), and the median body weight was 9.1 kg (range, 4.3 to 15 kg). Two patients had multiple ventricular septal defects (VSDs; additional perimembranous VSD in 1 patient and multiple MVSDs in the other) and 3 patients had associated cardiac anomalies; complete transposition of the great arteries in 1 patient and an atrial septal defect in 2 patients. All the procedures were performed on beating hearts, exception in 1 case. The ADO selected for the aortic side was at least 1 to 2 mm larger than the largest VSD in the left ventricle side. Results: The procedure was successful in all patients and each device was well positioned. During the median follow-up of 2.4 years, a small residual VSD was noted in 2 patients who had multiple VSDs and no leakage was seen in the other 3 patients. Conclusion: Perventricular closure of MVSD with an ADO is a good option for patients with apical MVSD. However, careful manipulation is important, especially in the case of small infants.

댐체 물성 평가를 위한 S파 반사법에 관한 연구 (A Study on S-wave Reflection method for the assessment of physical property of dam body)

  • 김형수;김중열;하익수;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.392-399
    • /
    • 2005
  • Shear modulus (or rigidity) of dam material is an important parameter which can be directly associated with the deformation of dam. Seepage or leakage of water can cause the defects or cracks of dam body. The existence of cracks and rigidity of dam body are decisive information for the estimation of dam safety. Rigidity of material is mainly determined from S-wave velocity and the defects of dam body can be detected by seismic reflection survey. Therefore, seismic reflection survey will be a desirable method which can give a solution about dam safety problem. Among various physical properties of dam body, S-wave velocity is the most important information but it is not easy to get the information. In this study, diverse measuring techniques of S-wave reflection survey were attempted to get the information about S-wave velocity of dam body. Ultimately, S-wave velocity could be estimated by the analysis of SH reflection events which can be easily observed in shot gather data obtained from SH measuring technique. Meanwhile, P-wave reflection survey was also performed at the same profile. P-beam radiation technique which can reduce the surface waves and reinforce the P-wave reflection events was applied for giving a help to analyse P-wave velocity. In the end, P-and S-wave velocity, Vs/Vp, Poisson's ratio distribution of the vertical section under the profile could be acquired.

  • PDF

원격장 와전류 배관 탐상 시스템 개발 (Development of Remote Field Eddy Current Pipeline Inspection System)

  • 정진오;이재경;김형진
    • 비파괴검사학회지
    • /
    • 제21권5호
    • /
    • pp.556-560
    • /
    • 2001
  • 배관의 관벽투과 특성을 지닌 원격장 와전류 비파괴 검사법은 열교환기 세관 검사에서부터 천연가스 수송관에 이르기까지 다양한 형태의 배관과 결함을 대상으로 적용 연구가 진행되고 있다. 공칭 외경 100mm의 주철관은 주로 상수도 관로의 배수관으로 활용되고 있는데, 차량 진동과 부식에 의한 결함의 생성으로 정수의 누수 문제를 일으킨다. 그러나, 탐상 경제성 및 효용성 문제로 관내 검사장치 투입과 같은 직접적인 검사 방법의 수행이 제한되어 왔다. 원격장 와전류 방법은 시스템 구성이 용이하고 내 외부 부식 결함에 대한 정량적인 평가가 가능하기 때문에 경제성 있는 장치 개발이 가능하다. 본 연구에서는 원격장 와전류 기술을 이용하여 상수도 관망의 특성을 고려한 매설 배관 검사시스템 개발을 수행하였다. 세부적으로는 관내 투입 원격장 와전류 검사의 기구부 설계 및 제작, 원격장 와전류 신호의 획득 및 처리 프로그램 개발, 그리고 개발 장치의 운용 방법 및 절차 검토 등으로 되어 있다.

  • PDF