• Title/Summary/Keyword: Leakage Defects

Search Result 176, Processing Time 0.025 seconds

Study on the Distortion of Detecting Signals with the Multi-Defects in Magnetic Flux Leakage System (자기누설탐상시스템에서 밀집된 다수의 결함에 의한 탐상 신호 왜곡에 관한 연구)

  • Seo, Kang;Kim, Dug-Gun;Han, Jea-Man;Park, Gwan-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.876-883
    • /
    • 2007
  • The magnetic flux leakage(MFL) type nondestructive testing(NDT) method is widely used to detect corrosion, defects and mechanical deformation of the underground gas pipelines. The object pipeline is magnetically saturated by the magnetic system with permanent magnet and yokes. Hall sensors detect the leakage fields in the region of the defect. The defects are sometimes occurred in group. The accuracy of the detecting signals in this defect cluster become lowered because of the complexity of the defect cluster. In this paper, the effects of the multi -defects are analyzed. The detecting signals are computed by 3-dimensional finite element method and compared with real measurement. The results say that, rather than the size of the defects, the effects of the relative position of the multi-defects are very important on the detecting signals.

Implementation of a Modified SQI for the Preprocessing of Magnetic Flux Leakage Signal

  • Oh, Bok-Jin;Choi, Doo-Hyun
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.357-360
    • /
    • 2013
  • A modified SQI method using magnetic leakage flux (MFL) signal for underground gas pipelines' defect detection and characterization is presented in this paper. Raw signals gathered using MFL signals include many unexpected noises and high frequency signals, uneven background signals, signals caused by real defects, etc. The MFL signals of defect free pipelines primarily consist of two kinds of signals, uneven low frequency signals and uncertain high frequency noises. Leakage flux signals caused by defects are added to the case of pipelines having defects. Even though the SQI (Self Quotient Image) is a useful tool to gradually remove the varying backgrounds as well as to characterize the defects, it uses the division and floating point operations. A modified SQI having low computational complexity without time-consuming division operations is presented in this paper. By using defects carved in real pipelines in the pipeline simulation facility (PSF) and real MFL data, the performance of the proposed method is compared with that of the original SQI.

Quality control plan for water leaks through step-by-step review of modular housing (모듈러 주택 단계별 검토를 통한 누수하자 품질관리 방안)

  • Cho, In-Su;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.169-170
    • /
    • 2023
  • Leakage defects account for a significant proportion of defect cases in modular homes. There are factors that can cause leakage defects at each stage, and quality control measures are required to minimize them. An improvement plan to prevent leakage defects was applied from the design drawings to the site of a modular public rental apartment complex in Sejong City 6-3, and a quality control plan was proposed to minimize leakage defects in the remaining process processes.

  • PDF

Analyzing Leakage Defect Types in Educational Facilities and Deriving Key Management Strategies Using the FTA Method (FTA기법을 이용한 교육시설 누수 하자 유형 분석 및 주요 원인 관리방안 )

  • Jung, Daegyo;Park, Hyunjung;Lee, Dongyeop;Kim, Daeyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.25 no.1
    • /
    • pp.42-49
    • /
    • 2024
  • In recent years, the construction industry has diligently focused on improving the quality and safety of buildings through smart technologies. However, there is a growing trend of leakage defects, especially in educational facilities, due to aging. The objective of this study is to analyze the causes of these defects in educational environments using the Fault Tree Analysis (FTA) technique and propose preventive measures based on the findings. The FTA technique is explained through a review of domestic literature, and data from the Educational Support Center from 2019 to 2021 are examined to identify major defects. The construction of the Fault Tree (FT) for leakage defects resulted in the identification of 12 basic events. Subsequently, a comprehensive understanding of the causes of leakage is achieved through FTA analysis, leading to the identification of the primary causes of defects. Leakage defects accounted for 46.8% of all reported issues in educational facilities, with roof (ceiling) leaks being the most common problem. FTA analysis revealed that poor substrate treatment was the main cause of roof (ceiling) leaks, which could be attributed to cracks in the waterproof layer, joint cracks, and microvoids in the waterproof layer. The primary achievement of this research is to provide essential data for preventing leakage defects in educational facilities and developing preventive measures through the FTA technique. These results are expected to significantly enhance the management of educational facilities and the prevention of leakage issues.

A Study on the Signal Correction for Multiple Defects in MFL Type Nondestructive Testing System (MFL 비파괴 검사 시스템에서 다중 결함에 의한 신호 왜곡과 신호 보정에 관한 연구)

  • Park, Jeng Hoon;Kim, Hui Min;Park, Gwan Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.24-30
    • /
    • 2016
  • MFL (Magnetic flux leakage) type nondestructive testing has been used for inspection of underground gas pipelines to find metal defects by detecting magnetic leakage signal. Because the underground gas pipeline is exposed by environment such as high pressure with great humidity, external defects are easily formed on the surface of pipelines and they are being grouped respectively. These adjacent defects cause the signal distortion of leakage flux so that it is hard to estimate the shape information of defects. In this paper, we performed to study of the signal distortion and compensating method for multiple defects in MFL type nondestructive testing system by using 3D FEM simulation. This paper proposes the basic algorithm of defect signal analysis on multiple defects on the surface of 30 inch diameter pipeline.

Magnetic Flux Leakage (MFL) based Defect Characterization of Steam Generator Tubes using Artificial Neural Networks

  • Daniel, Jackson;Abudhahir, A.;Paulin, J. Janet
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.34-42
    • /
    • 2017
  • Material defects in the Steam Generator Tubes (SGT) of sodium cooled fast breeder reactor (PFBR) can lead to leakage of water into sodium. The water and sodium reaction will lead to major accidents. Therefore, the examination of steam generator tubes for the early detection of defects is an important requirement for safety and economic considerations. In this work, the Magnetic Flux Leakage (MFL) based Non Destructive Testing (NDT) technique is used to perform the defect detection process. The rectangular notch defects on the outer surface of steam generator tubes are modeled using COMSOL multiphysics 4.3a software. The obtained MFL images are de-noised to improve the integrity of flaw related information. Grey Level Co-occurrence Matrix (GLCM) features are extracted from MFL images and taken as input parameter to train the neural network. A comparative study on characterization have been carried out using feed-forward back propagation (FFBP) and cascade-forward back propagation (CFBP) algorithms. The results of both algorithms are evaluated with Mean Square Error (MSE) as a prediction performance measure. The average percentage error for length, depth and width are also computed. The result shows that the feed-forward back propagation network model performs better in characterizing the defects.

Optimum Design of a Non-Destructive Testing System to Maximize Magnetic Flux Leakage

  • Park, G.S;Jang, P.W;Rho, Y.W
    • Journal of Magnetics
    • /
    • v.6 no.1
    • /
    • pp.31-35
    • /
    • 2001
  • This paper describes the design method of a magnetic system to maximize the magnetic flux leakage (MFL) in a non-destructive testing (NDT) system. The defect signals in a MFL type NDT system mainly depend on the change of the magnetic leakage flux in the region of a defect. The characteristics of the B-H curves are analysed and a design method to define the operating point on B-H curves for maximum leakage is performed. The computed MFL signal by a nonlinear finite element method is verified by measurement using Hall sensors mounted on the 6 legs PIG, the traveling detector unit in gas pipe, in an 8 inch test tube with defects. The rhombic defects could be successfully identified from the defect signals.

  • PDF

Analysis of temperature monitoring data for leakage detection of earth dam (흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석)

  • Oh, Seok-Hoon;Seo, Baek-Soo
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

Study of the Effects of the Antisite Related Defects in Silicon Dioxide of Metal-Oxide-Semiconductor Structure on the Gate Leakage Current

  • Mao, Ling-Feng;Wang, Zi-Ou;Xu, Ming-Zhen;Tan, Chang-Hua
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.2
    • /
    • pp.164-169
    • /
    • 2008
  • The effects of the antisite related defects on the electronic structure of silica and the gate leakage current have been investigated using first-principles calculations. Energy levels related to the antisite defects in silicon dioxide have been introduced into the bandgap, which are nearly 2.0 eV from the top of the valence band. Combining with the electronic structures calculated from first-principles simulations, tunneling currents through the silica layer with antisite defects have been calculated. The tunneling current calculations show that the hole tunneling currents assisted by the antisite defects will be dominant at low oxide field whereas the electron direct tunneling current will be dominant at high oxide field. With increased thickness of the defect layer, the threshold point where the hole tunneling current assisted by antisite defects in silica is equal to the electron direct tunneling current extends to higher oxide field.

Correlation between Physical Defects and Performance in AlGaN/GaN High Electron Mobility Transistor Devices

  • Park, Seong-Yong;Lee, Tae-Hun;Kim, Moon-J.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.2
    • /
    • pp.49-53
    • /
    • 2010
  • Microstructural origins of leakage current and physical degradation during operation in product-quality AlGaN/GaN high electron mobility transistor (HEMT) devices were investigated using photon emission microscopy (PEM) and transmission electron microscopy (TEM). AlGaN/GaN HEMTs were fabricated with metal organic chemical vapor deposition on semi-insulating SiC substrates. Photon emission irregularity, which is indicative of gate leakage current, was measured by PEM. Site specific TEM analysis assisted by a focused ion beam revealed the presence of threading dislocations in the channel below the gate at the position showing strong photon emissions. Observation of electrically degraded devices after life tests revealed crack/pit shaped defects next to the drain in the top AlGaN layer. The morphology of the defects was three-dimensionally investigated via electron tomography.