• 제목/요약/키워드: Leakage Current waveform

검색결과 31건 처리시간 0.023초

피뢰기 열화진단을 위한 저항분 누설전류의 측정장치 (Measurement Device of Resistive Leakage Current for Arrester Deterioration Diagnosis)

  • 길경석;한주섭;김정배
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.469-475
    • /
    • 2003
  • Resistive leakage current flowing ZnO blocks increases with its ages, which is an important indicator of arrester deterioration. However, a complicated circuitry is essential to measure the resistive leakage current included in the total leakage current, and the difficult handling of the measurement makes few applications to the fields. In this paper, we propose a resistive leakage current measurement device which is composed of a current detection circuit and an analysis program operated on a microprocessor. The device samples the input leakage current waveform digitally, and discriminate the zero-cross and the peak point of the waveform to analyze the current amplitude vs. phase. The capacitive leakage current is then eliminated from the total leakage current by using an algorithm to extract the resistive leakage current only. Also, the device can be operated automatically and manually to analyze the resistive leakage current even when the leakage current waveform is distorted due to various types of arrester deterioration. To estimate the performance of the device, we carried out a test on ZnO blocks and lightning arresters. From the results, it is confirmed that the device could analyze most parameters needed for the arrester diagnostics such as total leakage current. resistive leakage current, and the $3^rd$ harmonic leakage current.

누설전류 모니터링에 의한 옥외용 실리콘 고무의 열화 특성 평가 (The Evaluation of Degradation Characteristics of Silicone Rubber for Outdoor by Leakage Current Monitoring)

  • 김정호;송우창;조한구;박용관
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.60-64
    • /
    • 2001
  • The degradation process of silicone rubber was investigated by leakage current monitoring in Inclined-Plane method. DAS (Data Acquisition System) with 12-bit, 8-channel A/D converter was prepared. Average current, cumulative charge, current waveform and the number of peak pulses were measured on-line. And, FFT (Fast Fourier Transform) analysis was performed with stored current waveform. Besides, maximum erosion depth was measured in order to use as the indicator of the degradation process. So, the results of leakage current components and maximum erosion depth measurements were compared to find one or more components which have trends of changing similarly to that of erosion process. The result suggests that the ratio of peak current to r.m.s. current, harmonic contents and the number of peak pulses are well corresponding with the degradation process.

  • PDF

환경조건에 따른 EPDM 고분자 애자의 누설전류파형과 스펙트럼 분석 (Leakage Current Waveforms and Spectrum Analysis of EPDM Polymer Insulator according to Environment Condition)

  • 박재준;김정부;송영철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.82-86
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and rain) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonic waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

경사평면법에 의한 옥외용 실리콘 고무의 열화 특성 (Aging Characteristics of Silicone Rubber for Outdoor Use by Inclined-Plane Method)

  • 김정호;박용관;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.501-504
    • /
    • 1997
  • We investigated the tracking and erosion resistance of the silicone rubber by Inclined-Plane Method. And. with the variation of experiment time, the chance of the leakage current waveform was evaluated. The typical leakage current waveform was the form of mixture of sinusoidal wave and rectifying wave. It is thought that the sinusoidal wave is due to conductivity of contaminant when wet. and the rectifying wave is due to arc of dry band.

  • PDF

Salt fog에 의한 오손된 EPDM애자의 누설전류 파형 분석 (Analysis on Waveform of Leakage Current of Contaminated EPDM Insulators by Salt Fog)

  • 박재준;송영철;김정부;이유민;이현동;정영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.36-41
    • /
    • 2003
  • This paper presents the results of power spectra using the fundamental and low frequency harmonic components of leakage current waveform to study aging on contaminated EPDM insulator(was serviced during 1997-2001, region Pohang, korea) under salt fog conditions. Experiments have been conducted in the chamber salt fog and at the 16KVrms. The salt contents adjusted as 0g,25g,50g and 75g per liter of deionized water. The onset of dry-band arcing on polymer insulators could be determined by signal processing the low frequency harmonics components. A correlation has been found between the fundamental and low harmonic components of power spectra on leakage current. Where aging could be associated with an increase in the level of both the fundamental and low frequency harmonics components of leakage current. Surface aging for contaminated EPDM insulators occurred when the fundamental component of leakage current was greater then some level On the other hand, when the polymer insulator approached failure, the fundamental component of leakage current reached relatively high values and low frequency harmonics components of the leakage current trended to decrease. The results suggest that both the fundamental and low frequency harmonics of leakage current can be used as a tool to determine both the beginning of aging and before flashover, end of life EPBM insulator in salt fog.

  • PDF

반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템 (Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement)

  • 전정채;유재근
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

SALT FOG시 EPDM고분자애자의 누설전류파형과 스펙트럼분석 (Leakage Current Waveforms and Spectrum Analysis on Polymer Insulator of EPDM under Salt fog)

  • 박재준;양태규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 춘계종합학술대회
    • /
    • pp.500-504
    • /
    • 2004
  • 본 연구에서는 EPDM 고분자애자의 염무량 변화(salt:l0g, 25g, 50g, deionized water: 1000g)에 따른 표면방전과 환경적인 변화(salt fog 및 clean fog 그리고 raim)에 대한 누설전류 파형의 결과를 알아보았다. 기본파 및 3고조파 그리고 5고조파의 변화양상을 과전초기로부터 섬락시에 이르기까지 나타내었다. 표면열화의 진단기법을 개발하기위해서 누설전류파형의 주파수 스펙트럼을 이용하였고, 고분자애자의 표면열화에대한 환경적인 영향(clean fog, salt fog, rain)을 연구 하였다. 염분량의 변화시 기본파에 대한 저주파 고조파인 3고조파 및 5고조파에 대한 백분율(왜곡도)의 변화를 이용하여 표면 열화상태 및 정도를 정량화(a standard capacity)하여 나타내었다. 기본파에 대한 고조파 백분율인 왜곡율은 고분자 애자의 표면조건을 평가하는데 필요한 지시자라는 사실을 알 수 있었다.

  • PDF

옥외용 고분자 절연물의 표면 열화진단을 위한 아크파형 분석 (The Analysis of Arc Waveform for determing Surface Ageing of Polymeric Insulator for Out Door)

  • 문중섭;서광석;김정호;이재형;송우창;박용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2405-2407
    • /
    • 1999
  • In recent, the application of polymeric insulators for outdoor is significantly increasing. These materials have shown good performance in service, but had disadvantages under long-term exposure to contamination and moisture, resulting in some problems. Thus, this study concentrated on the development of technique evaluating the insulating status. Experiment was referred to lEC publ. 587, with data aquisition system to monitor leakage current. The components of leakage current investigated were waveform and 3rd harmonic. FFT was conducted for the analysis of harmonic components. The distortion of waveform with application time of voltage was evident, and so the 3rd harmonic component.

  • PDF

EPDM 고분자 애자에 대한 표면방전 및 누설전류파형의 고조파분석 (Harmonics Analysis of Leakage Current Waveforms and Surface Discharge for EPDM Polymer Insulator)

  • 박재준;양태규
    • 한국전기전자재료학회논문지
    • /
    • 제17권9호
    • /
    • pp.1013-1021
    • /
    • 2004
  • This paper presents the results of spectrum analysis of leakage current waveforms on contaminated polymer insulators under fog conditions. This is a basic study on development of a monitoring for aging degree and surface pollution state using distortion rate(%) of 3rd and 5th harmonics according fundamental frequency[60Hz] under environment conditions. Arcing on the surface was always associated with distortion in the leakage current ; hence the low frequency components of the leakage current can be used as a means to evaluate the surface degradation. The results indicate that the distortion rate by spectrum analysis is available for the monitoring of contamination condition of EPDM Polymer insulators.

사무용 빌딩에서의 전압 및 전류파형 왜곡특성 분석 (Analysis of Volatage and Current Waveform Distortion Characteristics at Office Buildings)

  • 유재근;이상익;전정채;정종욱;임용배
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.155-161
    • /
    • 2005
  • 사무용 빌딩의 비선형 전자부하에 기인한 전압 및 전류파형의 왜곡은 중성선의 과열, 변압기 손실, 누전차단기 오동작 등을 야기 시킨다. 본 논문에서는 사무용 빌딩에서의 전압 및 전류 고조파의 크기, 전압 및 전류 파고율(Crest Factor : CF), 전압 및 전류 불평형 등을 비교함으로써 파형왜곡 특성을 분석하였다. 분석 결과, 고조파에 의한 상 및 중성선에서의 심각한 파형 왜곡 문제와 삼상에서의 단상 부하의 부적절한 분배로 인한 전류 불평형이 심한 빌딩이 조사되었다. 본 연구 결과는 사무용 빌딩에서 합리적이고 경제적인 부하운용을 위해 사용될 수 있을 것이다.