• Title/Summary/Keyword: Leakage Current waveform

Search Result 31, Processing Time 0.021 seconds

Measurement Device of Resistive Leakage Current for Arrester Deterioration Diagnosis (피뢰기 열화진단을 위한 저항분 누설전류의 측정장치)

  • 길경석;한주섭;김정배
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.469-475
    • /
    • 2003
  • Resistive leakage current flowing ZnO blocks increases with its ages, which is an important indicator of arrester deterioration. However, a complicated circuitry is essential to measure the resistive leakage current included in the total leakage current, and the difficult handling of the measurement makes few applications to the fields. In this paper, we propose a resistive leakage current measurement device which is composed of a current detection circuit and an analysis program operated on a microprocessor. The device samples the input leakage current waveform digitally, and discriminate the zero-cross and the peak point of the waveform to analyze the current amplitude vs. phase. The capacitive leakage current is then eliminated from the total leakage current by using an algorithm to extract the resistive leakage current only. Also, the device can be operated automatically and manually to analyze the resistive leakage current even when the leakage current waveform is distorted due to various types of arrester deterioration. To estimate the performance of the device, we carried out a test on ZnO blocks and lightning arresters. From the results, it is confirmed that the device could analyze most parameters needed for the arrester diagnostics such as total leakage current. resistive leakage current, and the $3^rd$ harmonic leakage current.

The Evaluation of Degradation Characteristics of Silicone Rubber for Outdoor by Leakage Current Monitoring (누설전류 모니터링에 의한 옥외용 실리콘 고무의 열화 특성 평가)

  • Kim, Jeong-Ho;Song, Woo-Chang;Cho, Han-Goo;Park, Yong-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.60-64
    • /
    • 2001
  • The degradation process of silicone rubber was investigated by leakage current monitoring in Inclined-Plane method. DAS (Data Acquisition System) with 12-bit, 8-channel A/D converter was prepared. Average current, cumulative charge, current waveform and the number of peak pulses were measured on-line. And, FFT (Fast Fourier Transform) analysis was performed with stored current waveform. Besides, maximum erosion depth was measured in order to use as the indicator of the degradation process. So, the results of leakage current components and maximum erosion depth measurements were compared to find one or more components which have trends of changing similarly to that of erosion process. The result suggests that the ratio of peak current to r.m.s. current, harmonic contents and the number of peak pulses are well corresponding with the degradation process.

  • PDF

Leakage Current Waveforms and Spectrum Analysis of EPDM Polymer Insulator according to Environment Condition (환경조건에 따른 EPDM 고분자 애자의 누설전류파형과 스펙트럼 분석)

  • Park, Jae-Jun;Kim, Jeong-Boo;Song, Young-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.82-86
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and rain) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonic waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

Aging Characteristics of Silicone Rubber for Outdoor Use by Inclined-Plane Method (경사평면법에 의한 옥외용 실리콘 고무의 열화 특성)

  • 김정호;박용관;조한구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.501-504
    • /
    • 1997
  • We investigated the tracking and erosion resistance of the silicone rubber by Inclined-Plane Method. And. with the variation of experiment time, the chance of the leakage current waveform was evaluated. The typical leakage current waveform was the form of mixture of sinusoidal wave and rectifying wave. It is thought that the sinusoidal wave is due to conductivity of contaminant when wet. and the rectifying wave is due to arc of dry band.

  • PDF

Analysis on Waveform of Leakage Current of Contaminated EPDM Insulators by Salt Fog (Salt fog에 의한 오손된 EPDM애자의 누설전류 파형 분석)

  • Park, Jae-Jun;Song, Young-Chul;Kim, Jeong-Boo;Lee, You-Min;Lee, Hyun-Dong;Jung, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.36-41
    • /
    • 2003
  • This paper presents the results of power spectra using the fundamental and low frequency harmonic components of leakage current waveform to study aging on contaminated EPDM insulator(was serviced during 1997-2001, region Pohang, korea) under salt fog conditions. Experiments have been conducted in the chamber salt fog and at the 16KVrms. The salt contents adjusted as 0g,25g,50g and 75g per liter of deionized water. The onset of dry-band arcing on polymer insulators could be determined by signal processing the low frequency harmonics components. A correlation has been found between the fundamental and low harmonic components of power spectra on leakage current. Where aging could be associated with an increase in the level of both the fundamental and low frequency harmonics components of leakage current. Surface aging for contaminated EPDM insulators occurred when the fundamental component of leakage current was greater then some level On the other hand, when the polymer insulator approached failure, the fundamental component of leakage current reached relatively high values and low frequency harmonics components of the leakage current trended to decrease. The results suggest that both the fundamental and low frequency harmonics of leakage current can be used as a tool to determine both the beginning of aging and before flashover, end of life EPBM insulator in salt fog.

  • PDF

Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement (반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템)

  • Jeon, Jeong Chay;Yoo, Jae-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

Leakage Current Waveforms and Spectrum Analysis on Polymer Insulator of EPDM under Salt fog (SALT FOG시 EPDM고분자애자의 누설전류파형과 스펙트럼분석)

  • 박재준;양태규
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.500-504
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and .am) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonir waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

The Analysis of Arc Waveform for determing Surface Ageing of Polymeric Insulator for Out Door (옥외용 고분자 절연물의 표면 열화진단을 위한 아크파형 분석)

  • Moon, J.S.;Seo, K.S.;Kim, J.H.;Lee, J.H.;Song, W.C.;Park, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2405-2407
    • /
    • 1999
  • In recent, the application of polymeric insulators for outdoor is significantly increasing. These materials have shown good performance in service, but had disadvantages under long-term exposure to contamination and moisture, resulting in some problems. Thus, this study concentrated on the development of technique evaluating the insulating status. Experiment was referred to lEC publ. 587, with data aquisition system to monitor leakage current. The components of leakage current investigated were waveform and 3rd harmonic. FFT was conducted for the analysis of harmonic components. The distortion of waveform with application time of voltage was evident, and so the 3rd harmonic component.

  • PDF

Harmonics Analysis of Leakage Current Waveforms and Surface Discharge for EPDM Polymer Insulator (EPDM 고분자 애자에 대한 표면방전 및 누설전류파형의 고조파분석)

  • 박재준;양태규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.1013-1021
    • /
    • 2004
  • This paper presents the results of spectrum analysis of leakage current waveforms on contaminated polymer insulators under fog conditions. This is a basic study on development of a monitoring for aging degree and surface pollution state using distortion rate(%) of 3rd and 5th harmonics according fundamental frequency[60Hz] under environment conditions. Arcing on the surface was always associated with distortion in the leakage current ; hence the low frequency components of the leakage current can be used as a means to evaluate the surface degradation. The results indicate that the distortion rate by spectrum analysis is available for the monitoring of contamination condition of EPDM Polymer insulators.

Analysis of Volatage and Current Waveform Distortion Characteristics at Office Buildings (사무용 빌딩에서의 전압 및 전류파형 왜곡특성 분석)

  • Yoo, Jae-Geun;Lee, Sang-lck;Jeon, Jeong-Chay;Jeong, Jong-Wook;Lim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.155-161
    • /
    • 2005
  • Nonlinear electronic loads used at office buildings distort the voltage and current waveform that cause the overheating of transformer losses, ELB(Electrical Leakage Breaker) tripping, and so on. This paper analyzed waveform distortion characteristics at several once buildings by comparing with magnitude of voltage and current harmonics, crest factor of voltage and current, phase voltage and current unbalance. As a consequence, severe current waveform distortion in phase and neutral line by harmonics and high current unbalance rates by unbalanced using of single loads among the three phases are investigated. The results of the study can be used in making decisions regarding reasonable and economical operating of loads at office buildings.