• Title/Summary/Keyword: Leakage Accident

Search Result 268, Processing Time 0.023 seconds

Economic Analysis of Optical Communication Control System in High Voltage Magnetizer (고전압 착자기에서의 누전 사고 방지를 위한 광통신 제어시스템의 도입 방안과 경제성 분석)

  • Bae, Young Woo;Kim, Wooju;Hong, June Seok
    • Journal of Information Technology Applications and Management
    • /
    • v.26 no.6
    • /
    • pp.103-117
    • /
    • 2019
  • Demand for high power motors is rapidly increasing as the 4th industry and convergence technology has recently emerged. In order to produce high-strength permanent magnets, the magnets used for magnetization have been increased from DC 300V in the 1970s to DC 2.5kV in the 2010s, Up to DC 10kV in the 2030s, It is expected that higher voltage will be used to magnetize. However, in the case of a magnetizer using an existing electric signal control device, it is necessary to use a control device with a high-voltage insulation function in case a high voltage used for magnetization is leaked to the control device. If a short circuit accident occurs, the controller must be shut down and serious problems such as excessive repair costs arise. In this study, a control system adopting optical communication method instead of electric signal control method is proposed to prevent leakage currents in high-voltage magnetizer. We design a transmitter(Tx) and a receiver(Rx) device for the optical communication control device and implemented a prototype connecting the optical cable. In order to demonstrate the utility of high-voltage magnetizer using the optical communication control device, we analyzed the initial cost and the yearly cost for the years to analyze the net present value. As a result, In the case of the low-voltage magnetizer, the electric signal control method cost less, As the operating voltage of the magnetizer becomes higher. It is confirmed that it takes less cost when the optical communication control device is used.

Gravity, Magnetic and VLF explorations in the ubong industrial waste landfill, Pohang (포항 유봉산업 폐기물 매립지에서의 중력, 자력, VLF 탐사)

  • 권병두
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.177-187
    • /
    • 1999
  • Gravity, magnetic and VLF surveys were conducted to investigat the structural stability and hazards associated with the Ubong landfill in Pohang City, which has been built to dump industrial wastes. In 1994, the collapse of a bank happened in the 6th landfill site due to sudden heavy rain, and a large quantity of waste materials flowed out to the nearby landfill sites, factories and roads. We used $10{\times}10m$ resolution DEM data for gravity reductions. The maximum variation of the terrain effect in the survey area is about 0.5 mgal and the terrain effect is large in the vicinity of bank boundary. The Bouguer gravity anomaly map shows the effect due to the variatino of thickness and type of waste materials. The small negative gravity anomaly increases from the 9th site to the 6th site. The small negative gravity anomaly of the 9th site reflects the relatively shallow dumping depth of average 14.5 m in this site and increased density of waste materials by the repeated stabilization process of soil overlaying. The 6th site is located at the center of the former valley and rainfall and groundwater are expected to flow from south-east to north-west. Therefore, considering the previous accident of mixing waste and bank materials at the north-west boundary of the landfill, there may be some environmental problems of leakage of contaminated water and bank stability. The complex inversion technique using Simulated annealing and Marquardt-Levenberg methods was applied to calculate three-dimensional density distribution from gravity data. In the case of 6th site, it is apparent that the landfill had been dumped in four sectors. However, most part of the 9th site and showed that high magnetic industrial wastes were concentrated in the 6th site. The result of magnetic survey showing low magnetic anomalies along the boundaries of two sites is similar to that of gravity data. The VLF data also reveals four divided sectors in the 6th site, and overall anomaly trend indicates the directio of former valley.

  • PDF

Accidents Analysis of Domestic and Overseas Refueling Stations and Assessment of Dangerous Distance by Gas Leak (국내·외 충전소 사고 현황 분석 및 가스누출 피해거리 평가)

  • Kim, Hyelim;Kang, SeungKyu;Huh, YunSil
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2017
  • As environmental problems become a problem of survival, interest in eco-friendly energy is increasing to improve the environment. So, demand for eco-friendly fuels such as hydrogen, LPG and CNG is increasing. In particular, Korea, which relies on imports of most fuels, is investing in the development of hydrogen energy, which is favorable in terms of high production volume and energy independence. However, As demand grows every year, a variety of accidents occur in various ways, ranging from small leak incidents to massive fires and explosion, thus research needs to be done. So, in this study, compared and analyzed cases of hydrogen, LPG, CNG accidents occurring at domestic and overseas refueling stations. and various programs were used for assessing risk, estimated the flame length due to gas leakage and evaluated the dangerous distance.

A Study on Total Hazard Level Algorithm Development for Hazardous Chemical Substances (유해화학물질의 종합위해등급 알고리즘 개발에 관한 연구)

  • 고재선;김광일;정상태
    • Fire Science and Engineering
    • /
    • v.14 no.4
    • /
    • pp.7-16
    • /
    • 2000
  • In the study, three criteria(toxicity, fire & explosion, environment) and damage prediction method for each case was set up, and all these criteria were applied to the subject substance that was selected as hazardous level by integrating all criteria through Algorithm. Particularly, the environment criterion is a comprehensive concept, environment index modeling by combining USCG(United State Coast Guard) & MSDS(Material Safety Data Sheet) environment criteria classifications and the environment part of MFPA's health hazardousnes(Nh). And for damage prediction method of each criterion were adopted and they were applied to hazardous chemical substances in use or stored by chemical substance related enterprises located in each region that made possible to set up total hazard level of used substances(inflammability, poisonousness and counteraction on a unit substance, and hazard level & display modeling on environment) & damage prediction in case of accident & solidity setup(CPQRA: Chemical Process Quantitative Risk Assessment, IAEA: International Atomic Energy Agency, VZ eq: Vulnerable Zone) risk counter. Thus it is deemed that it can be applied to toxic substance leakage that can happen during any chemical processing & storage, application as a tool for prior safety evaluation through potential dangerousness computation of fire & explosion.

  • PDF

Automatic Ultrasonic Inspection on Heater Sleeves and J-Groove Welds of Pressurizer (가압기 전열기 슬리브 및 J-Groove 용접부의 자동 초음파검사)

  • Ryu, Sung Woo;Chang, Hee Jun;Kim, Sun Je;Lee, Sang Duck;Sung, Jong Hwan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.20-27
    • /
    • 2010
  • In order to prevent the corrosion of component contacted primary water designed alloy 600 material in the nuclear power plant. But the primary water stress corrosion cracking(PWSCC) of alloy 600 and weld area occurs continuously due to the residual stress. The leakage accident resulted from PWSCC in the drain nozzle of the steam generator of domestic power plants. Heater sleeves of the pressurizer are welded with alloy 600 weld material and therefore exposed to the primary water environment. PWSCC occurred in heater sleeve material and weld area of many foreign power plants. The current issue of domestic nuclear power plants are consequently concentrated to PWSCC of similar material. In order to improve the detection and the sizing of the PWSCC in the welding sleeve of the pressurizer, the automatic UT system and multi-directions probe sets have been developed. The experimental studies have been performed using the mock-up block containing artificial reflectors(ID connected EDM notch) and semi-artificial cracks made from thermal fatigue. The automatic UT System is applied in the detection and the length sizing of the ID/OD on the tube and the J-groove weld area of the artificial reflectors and results of the detection and the sizing are compared respectively. Also, the developed automatic UT system is successfully accomplished to inspect the heater sleeve and the J-groove weld area on the pressurizer for the detection of PWSCC.

  • PDF

A Study on the Cost Analysis of risk facilities using e-Consequence Analysis - Focusing Steel pipe Industry (e-CA(e-Consequence Analysis)를 활용한 위험설비의 비용 분석에 관한 연구 : 강관제조업 사례를 중심으로)

  • Kwon, Hyeok Min;Hwang, Yong Woo;Lee, Ik Mo;Chun, Young Woo;Choi, Young Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.3
    • /
    • pp.27-36
    • /
    • 2018
  • The steel pipe manufacturing industry deals with facilities and materials. Especially thermal facilities are close to vapor cloud explosion (VCE) and may cause secondary damage to facilities because they deal with corrosive substances such as hydrofluoric acid, sulfuric acid and acid, fire, explosion, leakage etc. It is in danger. In this study, hazard identification method was conducted using HAZOP techniques and quantitative risk analysis was conducted using e-CA, a program that supports accident impact analysis. Equipment in the influence range of ERPG - 3 was determined to be a facility requiring replacement. It was decided that neutralization is necessary using slaked lime. Based on the cost of loss, We presented the proper replacement which is the timing of the dangerous facility. As a result, It was ideal to replace the facilities with 20 years of heat treatment facilities, one year of hydrofluoric acid storage tank, 20 years of sulfuric acid storage tank, and 5 years of hydrochloric acid storage tank.

Software Design of Computerized Gas Safety Control System (컴퓨터에 의한 가스안전 제어시스템 소프트웨어 설계)

  • Kim Tae-Ok;Jou Wouseok;Park Hyunmin;Lee Hern-Chang;Chang Seo-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.1 s.22
    • /
    • pp.30-36
    • /
    • 2004
  • Although the usage of gas as one of the most economical energy source is ever expanding, numerous gas accidents occur as a result of negligence in safety management. The main reason behind such accident is that the current safety control system relies heavily on the manual control mechanism. This paper designed and developed a prototype of a computerized gas safety control system that automates such critical functions as the alarm sensing and the valve control. Since the system is connected through a digital network, the control can be performed remotely. Most importantly, the accidental risk or damage can be greatly reduced since the system monitors and reacts actively to gas leakage in real time.

  • PDF

Privacy-Preserving Kth Element Score over Vertically Partitioned Data on Multi-Party (다자 간 환경에서 수직 분할된 데이터에서 프라이버시 보존 k번째 항목의 score 계산)

  • Hong, Jun Hee;Jung, Jay Yeol;Jeong, Ik Rae
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.6
    • /
    • pp.1079-1090
    • /
    • 2014
  • Data mining is a technique to get the useful information that can be utilized for marketing and pattern analysis by processing the data that we have. However, when we use this technique, data provider's personal data can be leaked by accident. To protect these data from leakage, there were several techniques have been studied to preserve privacy. Vertically partitioned data is a state called that the data is separately provided to various number of user. On these vertically partitioned data, there was some methods developed to distinguishing kth element and (k+1) th element by using score. However, in previous method, we can only use on two-party case, so in this paper, we propose the extended technique by using paillier cryptosystem which can use on multi-party case.

Dependence of Explosion Overpressure of Flammable Gas on the Change of Volume Blockage Ratio of Facilities (설비 혼잡도에 따른 가연성 증기운의 폭발과압의 변화)

  • Lee, Seung Kuk;Lee, Da Eun;Kim, Sung Chan;Yoon, Kee Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.54-61
    • /
    • 2015
  • A series of CFD calculation has been conducted to investigate the effect of facility confinement on explosion power for process plant facility. The level of confinement of a facility was simplified with VBR(volume blockage ratio) and averaged size of obstacles. FLACS which is 3D CFD code of gas dispersion and the explosion was used for simulating the explosion phenomena in the idealized domain with different confinement level. The CFD results showed a tendency that the overpressure increases with increasing VBR and number of obstacles. The effect of VBR on the overpressure was relatively small for the case of number of obstacle less than 25. The results of this study can be used to provide a safety guideline considering the facility confinement in case of leakage accident of flammable gas and vapor in process plants.

A Study on Analysis of Laboratory Accident with Root Cause Analysis (근본원인분석 기법을 활용한 실험실 사고 분석에 관한 연구)

  • Eom, Seok-Hwa;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.1-5
    • /
    • 2010
  • Many sorts of fatal accidents like explosion or fire caused by gas leakage have become a social issue with the increasing use of harmful chemicals in laboratories in universities and enterprise-affiliated research institutes in Korea. Importance of safety management has been emphasized and it made Act on the Establishment of Safe Laboratory Environment enacted not only to protect lives and bodies of people working in laboratories in universities and enterprise-affiliated research institutes but also to make pleasant experimental atmosphere. Safety management system has been built and periodical checkups and safety diagnosis have been implementing in universities and enterprise-affiliated research institutes to prevent such accidents. However, in spite of those actions, continuous accidents make analysis of root cause essential. This study will show results of analysis on incidents and accidents occurred in laboratories in universities and enterprise-affiliated research institutes using Root Cause Analysis Method and propose the direction of safety management.