• Title/Summary/Keyword: Leak signal

Search Result 71, Processing Time 0.027 seconds

Development of TDR-based Water Leak Detection Sensor for Seawater Pipeline of Ship (시간영역반사계를 이용한 해수배관시스템의 누수 탐지용 센서 개발 연구)

  • Hwang, Hyun-Kyu;Shin, Dong-Ho;Kim, Heon-Hui;Lee, Jung-Hyung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1044-1053
    • /
    • 2022
  • Time domain reflectometry (TDR) is a diagnostic technique to evaluate the physical integrity of cable and finds application in leak detection and localization of piping system. In this study, a cable-shaped leak detection sensor was proposed using the TDR technique for monitoring leakage detection of ship's engine room seawater piping system. The cable sensor was developed using a twisted pair arrangement and wound by an absorbent material. The availability and performance of the sensor for leak detection and localization were evaluated on a lab-scale pipeline set up. The developed sensor was installed onto the pipes and flanges of the lab-scale set up and various TDR waveforms were acquired and analyzed according to the dif erent variables including the number of twists and sheath thickness. The result indicated that the twisted cable sensor was able to produce clear and smooth signal as compared to the TDR sensor with a parallel arrangement. The optimal number of twist was determined to be above 10 per the unit length. The optimal diameter of sheath thickness that results in the desired sensitivity was determined to be ranging from 80% up to 120% of the diameter of the conductor. The linear regression analysis for estimation of leak localization was carried out to estimate the location of the leakage, and the result was a determination coefficient of 0.9998, indicating a positive relationship with the actual leakage point. The proposed TDR based leak detection method appears to be an effective method for monitoring leakage of ship's seawater piping system.

Research on image data filtering methods for extreme environments after the nuclear leak accident

  • Minglei Zhu;Xiangkun Wu;Jun Qi;Yunlong Teng;Jinmao Jiang;Dawei Gong
    • Nuclear Engineering and Technology
    • /
    • v.56 no.10
    • /
    • pp.4227-4236
    • /
    • 2024
  • Nuclear energy is used more and more widely as a clean energy source, but nuclear energy facilities are risky, and when a nuclear leak occurs, it is necessary to detect equipment in a nuclear radiation environment. In the nuclear radiation environment, due to the impact of high-energy particles on the camera sensor, the collected image contains a lot of radiation noise, which greatly reduces the visual perception of the image. Aiming at the problem that radiation noise reduces image quality, a radiation image compound filtering algorithm combining median filtering and multi-frame average filtering is proposed based on radiation noise characteristics. Compared with several common filtering algorithms, the radiation noise image is filtered under the same radiation dose and achieve the highest Peak Signal Noise Rate (PSNR) and Structural Similarity (SSIM), and compared with the multi-frame average filtering method, the number of image frames required by the algorithm in this paper is greatly reduced. Experimental results show that the algorithm can effectively eliminate radiation noise and is more suitable for image filtering in radiation environment.

Analysis on the Vulnerability of Information Leakage through Electromagnetic Emanations from PC Keyboard (키보드 누설 방사에 의한 정보 누설 취약성 분석)

  • Lee, Dae-Heon;Hwang, In-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.1 s.116
    • /
    • pp.76-81
    • /
    • 2007
  • In this paper, we analyzed the vulnerability of information leakage due to the leakage electromagnetic waves of a PC keyboard. First, we reviewed the keyboard protocol and hardware structure, we analyzed the correlation between the data signal, which is transmitted from the keyboard to the main body, and the leakage signal on the power cable. With the result, we grasped the cause of the Conducted Emission of a PC keyboard. Also, we compared the limit level of the CISPR 22 standard with the amplitude of the keyboard leakage electromagnetic waves we calculated. By analyzing the signal on the power cable of the PC main body through the simple experiment, we show that it is possible to extract the contents of the PC key. Therefore it is verified that the secret information of the PC user could leak out.

Model-Based Detection of Pipe Leakage at Joints (모델 기반 파이프 연결부 누수 감지 시스템)

  • Kim, Taejin;Youn, Byeng D.;Woo, Sihyeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.3
    • /
    • pp.347-352
    • /
    • 2015
  • Time domain reflectometry (TDR) is widely used for wire failure detection. It transmits a pulse that is reflected at the boundaries of different characteristic impedances. By analyzing the reflected signal, TDR makes it possible to locate the failure. In this study, TDR was used to detect the water leakage at a pipe joint. A wire attached to the pipe surface was soaked by water when a leak occurred, which affected the characteristic impedance of the wet part, resulting in a change in the reflected signal. To infer the leakage from the TDR signal, we first developed a finite difference time domain-based forward model that provided the output of the TDR signal given the configuration of the transmission line. Then, by solving the inverse problem, the locations of the leaks were found.

Characteristics of Corrosion Damages in Bottom Plate of Above Ground Tank by Acoustic Emission Signal (지상탱크 저판부의 부식손상 평가를 위한 음향방출 신호의 분석)

  • Kim, Sung-Dai;Jung, Woo-Gwang;Lee, Jong-O
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.64-72
    • /
    • 2007
  • Under the AE methods, the valid condition analysis and evaluation the leak etc, resulted by the AE signal pattern on the bottom plate of ground tank at full. In next more, the gradient of accumulation amplitude distribution analysis and comparison the energy, count, and duration time that noise of EMI signal were removed. EMI signal showed height-energy, count, and duration time, it also appeared great gradient of accumulation distribution. Then, with the pure remaining AE signals cluster analysis and location. It would possibly assume of damage with corrosion. Total cluster 20 and energy showed between the maximum 11,990 and 8,565 which is much lower than above figure and event number showed from 8 to 5. Even when it difficult to certify damage by open, as it is raised higher height-sensitivity and threshold by 60 dB. It would possibly presume of location source more accurately.

  • PDF

FINITE ELEMENT MODEL TO STUDY CALCIUM DIFFUSION IN A NEURON CELL INVOLVING JRYR, JSERCA AND JLEAK

  • Yripathi, Amrita;Adlakha, Neeru
    • Journal of applied mathematics & informatics
    • /
    • v.31 no.5_6
    • /
    • pp.695-709
    • /
    • 2013
  • Calcium is well known role for signal transduction in a neuron cell. Various processes and parameters modulate the intracellular calcium signaling process. A number of experimental and theoretical attempts are reported in the literature for study of calcium signaling in neuron cells. But still the role of various processes, components and parameters involved in calcium signaling is still not well understood. In this paper an attempt has been made to develop two dimensional finite element model to study calcium diffusion in neuron cells. The JRyR, JSERCA and JLeak, the exogenous buffers like EGTA and BAPTA, and diffusion coefficients have been incorporated in the model. Appropriate boundary conditions have been framed. Triangular ring elements have been employed to discretized the region. The effect of these parameters on calcium diffusion has been studied with the help of numerical results.

Detecting steam leakage by using correction of camera vibrating (카메라 흔들림 보정을 통한 증기 누설 탐지)

  • Choi, Young-Chul;Yoon, Chan-Hoon;Kim, Jin-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.394-398
    • /
    • 2014
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. Recently, the research detecting the steam leakage by using camera image is introduced. However, this method has a disadvantage. If a camera oscillates, it cannot detect a steam leakage exactly. In this paper, the technique that reduces the error due to a camera shaking is proposed. To verify the proposed method, we have performed the experiments for the oil leakage experiments. The results show that the technique can calibrate the error due to camera shaking.

  • PDF

Correction of Error due to Camera Vibrating During Detecting Steam Leakage by Using Image (영상을 이용한 누설탐지에서 카메라 진동 오차 보정)

  • Choi, Young-Chul;Jeon, Hyeong-Seop;Son, Ki-Sung;Park, Jong Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.10
    • /
    • pp.795-801
    • /
    • 2014
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. Recently, the research detecting the steam leakage by using camera image is introduced. However, this method has a disadvantage. If a camera oscillates, it cannot detect a steam leakage exactly. In this paper, the technique that reduces the error due to a camera shaking is proposed. To verify the proposed method, we have performed the experiments for the oil leakage experiments. The results show that the technique can calibrate the error due to camera shaking.

Developing an Early Leakage Detection System for Thermal Power Plant Boiler Tubes by Using Acoustic Emission Technology (음향방출법을 이용한 발전용 보일러 튜브 미세누설 조기 탐지 시스템 개발 및 성능 검증)

  • Lee, Sang Bum;Roh, Seon Man
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.181-187
    • /
    • 2016
  • A thermal power plant has a heat exchanger tube to collect and convert the heat generated from the high temperature and pressure steam to energy, but the tubes are arranged in a complex manner. In the event that a leakage occurs in any of these tubes, the high-pressure steam leaks out and may cause the neighboring tubes to rupture. This leakage can finally stop power generation, and hence there is a dire need to establish a suitable technology capable of detecting tube leaks at an early stage even before it occurs. As shown in this paper, by applying acoustic emission (AE) technology in existing boiler tube leak detection equipment (BTLD), we developed a system that detects these leakages early enough and generates an alarm at an early stage to necessitate action; the developed system works better that the existing system used to detect fine leakages. We verified the usability of the system in a 560MW-class thermal power plant boiler by conducting leak tests by simulating leakages from a variety of hole sizes (ⵁ2, ⵁ5, ⵁ10 mm). Results show that while the existing fine leakage detection system does not detect fine leakages of ⵁ2 mm and ⵁ5 mm, the newly developed system could detect leakages early enough and generate an alarm at an early stage, and it is possible to increase the signal to more than 18 dB.

Tribological Failure Examples Involving Hydraulic Unit, Sensor, Computer of Anti-lock Brake System in Passenger Cars (승용차 ABS의 하이드로릭 유닛, 센서, 컴퓨터에 관련된 트라이볼로지적인 고장사례 고찰)

  • Lee, IlKwon;Han, JaeOh;Lee, JongHo;Lee, YoungSuk;Kim, ChooHa
    • Tribology and Lubricants
    • /
    • v.30 no.3
    • /
    • pp.183-188
    • /
    • 2014
  • In this paper, we present our analysis of tribological failure examples for an anti-lock brake system(ABS) in a car. The study range of this paper is to improve the quality of ABS system by analyzing with sensor, computer, actuator and oil lines. In the first example, the brake leak from hydraulic supply line in a caliper on the rear left side of the ABS hydraulic modulator. This produces the sponge phenomenon, where the car does not brake even when the driver operates the brake pedal. The hydraulic unit operating ABS is actuator that play role regulating drive condition according with the oil pressure supplied with wheel of a car. In the second example, the service man does not completely tighten the fixed bolt after repairing the car. This causes the ABS warning lamp to light up as the ABS wheel speed sensor cannot detect whether the ABS has been activated. In the third example, the ABS electronic control unit is separated from the soldered part of the inner circuit board. Consequently, the ABS fails in control because the ABS motor pump receives no-signal for the hydraulic unit. The wheel speed sensor has to large durability because of giving signal of acting condition to computer by detected the acceleration and deceleration of wheel of a car. In the fourth example, the ABS warning lamp lights up of when cracks propagate in the circuit board soldering part. The circuit of this computer is very important part for input and output the operating signal of system. Such failures can aggravate the durability of the ABS. Thus, the ABS needs to be optimized to eliminate malfunction phenomenon.