Characteristics of Corrosion Damages in Bottom Plate of Above Ground Tank by Acoustic Emission Signal

지상탱크 저판부의 부식손상 평가를 위한 음향방출 신호의 분석

  • Kim, Sung-Dai (Dept. of Qulity Non Destructive Testing, Seoul Sanggye Vocation School) ;
  • Jung, Woo-Gwang (Dept. of Advanced Materials Engineering, Kookmin University) ;
  • Lee, Jong-O (Dept. of Nondestructive Evaluation Group Test & Evaluation, Korea Institute of Machinery & Materials)
  • 김승대 (서울시립상계직업전문학교 품질비파괴검사과) ;
  • 정우광 (국민대학교 신소재공학과) ;
  • 이종오 (한국기계연구원 시험평가센터 비파괴평가그룹)
  • Published : 2007.12.30

Abstract

Under the AE methods, the valid condition analysis and evaluation the leak etc, resulted by the AE signal pattern on the bottom plate of ground tank at full. In next more, the gradient of accumulation amplitude distribution analysis and comparison the energy, count, and duration time that noise of EMI signal were removed. EMI signal showed height-energy, count, and duration time, it also appeared great gradient of accumulation distribution. Then, with the pure remaining AE signals cluster analysis and location. It would possibly assume of damage with corrosion. Total cluster 20 and energy showed between the maximum 11,990 and 8,565 which is much lower than above figure and event number showed from 8 to 5. Even when it difficult to certify damage by open, as it is raised higher height-sensitivity and threshold by 60 dB. It would possibly presume of location source more accurately.

충수된 지상 탱크 저판부에서 발생하는 AE 신호 특성을 관찰하여 누수 등 손상에 대한 신호를 분석, 평가하였다. EMI 잡음신호를 에너지, 카운트. 지속시간 등과 누적진폭 분포상의 기울기를 비교 분석하여 제거하였다. EMI 신호는 높은 에너지 카운트, 지속시간을 나타내며, 누적 분포상에서 큰 기울기를 갖는 특성을 보였다. 남은 AE 신호의 위치표정과 클러스터 분석을 통해 부식손상의 가능성을 추정할 수 있었으며 총 20개의 클러스터로 에너지는 최대 11,990에서 8,565까지 이벤트는 최대 8에서 5까지 나타났다. 개방에 의한 손상확인을 하지 못했으나 보다 높은 고감도의 센서와 문턱값을 60dB 이상 높여서 평가한 다면 보다 정확한 발생위치 추정이 가능하리라 본다.

Keywords