• 제목/요약/키워드: Leak noise

Search Result 79, Processing Time 0.028 seconds

Leak Detection of Circular Piping Systems by Using Unit Impulse Response Function Analysis (단위 충격 응답함수를 이용한 원형관 시스템의 주출감지 연구)

  • 전오성;윤병옥;김창호
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.337-343
    • /
    • 1994
  • A method of the leak detection from the pipe system by using accelerometer is proposed. The signal detected from accelerometer is proved experimentally to be a dispersive wave. Based on the experiments, a method using the narrow band pass filter and the unit impulse response function is analyzed. The method uses the characteristics of the unit impulse response function, that the function is available evenin the narrow band signal because, unlike the cross correlation, it is normalized by the auto spectrum. The accelerometer is quite easier to use than the hydrophone in adapting to the pipe system.

  • PDF

A Study on fluid leak detection technique for Safety valve (안전밸브 유체 누설 감지 기법에 대한 연구)

  • Kim, Dong soo;Ryu, Ho geun;Jang, Hoon;Chai, Jang bom
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.215-215
    • /
    • 2014
  • 현재 가장 많이 사용되고 있는 스프링식 안전밸브는 스프링과 설정치 드리프트, 누설 취약성, 채터링에 의한 시트 파손등의 문제점을 지니고 있다. 안전밸브 디스크에서 발생하는 유체 누설은 안전밸브 설정압력 개방에 영향을 주며, 시트(Seat)면의 이물질 삽입, 균열 및 유체에 의한 침식(Erosion) 등에 의해 밸브 핵심 부품이 쉽게 손상되어 기기 성능 저하를 초래하게 된다. 따라서 유체 누설을 조기에 탐지하고 정량화하여 해당 기기의 상태정보 제공을 통한 누설 감지 기법 연구가 요구된다. 원자력 발전소의 경우 밸브에서 유체가 누설되면 밸브의 오작동 및 운전 안정성 저해 요인이 된다. 따라서 본 연구에서는 음향방출법을 이용하여 안전밸브의 유체 누설을 평가하고, 안전밸브의 음향신호 측정 위치 선정 및 누설량에 따른 음향신호를 분석하고자 한다.

  • PDF

Steam Leak Detection by Using Image Signal (영상신호를 이용한 증기누설 검출 방법)

  • Choi, Young-Chul;Son, Ki-Sung;Jeon, Hyeong-Seop;Park, Jin-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.828-833
    • /
    • 2010
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. In this paper, we proposed the method for the detecting steam leakage by using image signal processing. Our basic idea come from heat shimmer which shine with a soft light that looks as if it shakes slightly. To test the performance of this technique, experiments have been performed for simple heat source and steam generator. Results show that the proposed technique is quite powerful in the steam leak detection.

Method of how to improve transmission loss of dry walls (조립형 건식벽체의 차음성능 개선 공법에 관한 연구)

  • Kim, Kyungho;Jeon, JinYong;Kim, SungHoon;Lee, HyungKi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.719-724
    • /
    • 2013
  • In the case of newly developed stud which has more performance of sound transmission loss, it is expected that sound would transmit through runner than stud. so we developed construction method of runner and stud. As a result, sound transmission loss is improved about 2 dB by using this method. But this construction method could be applied to only newly developed stud. In addition, sound leak of wall joint is about 2 dB, and it could be improved by using rubber gasket at joint.

  • PDF

Pipe Leak Detection System using Wireless Acoustic Sensor Module and Deep Auto-Encoder

  • Yeo, Doyeob;Lee, Giyoung;Lee, Jae-Cheol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.2
    • /
    • pp.59-66
    • /
    • 2020
  • In this paper, we propose a pipe leak detection system through data collection using low-power wireless acoustic sensor modules and data analysis using deep auto-encoder. Based on the Fourier transform, we propose a low-power wireless acoustic sensor module that reduces data traffic by reducing the amount of acoustic sensor data to about 1/800, and we design the system that is robust to noise generated in the audible frequency band using only 20kHz~100kHz frequency signals. In addition, the proposed system is designed using a deep auto-encoder to accurately detect pipe leaks even with a reduced amount of data. Numerical experiments show that the proposed pipe leak detection system has a high accuracy of 99.94% and Type-II error of 0% even in the environment where high frequency band noise is mixed.

External Wind Noise Source Identification in Hyundai Aeroacoustic Wind Tunnel (현대 자동차 무향 풍동에서의 외부 소음원 파악 기술)

  • 정승균
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.34-40
    • /
    • 2001
  • Aeroacoustic technology to improve the acoustic comfort in high-speed became a major topic in vehicle development process. Although most of wind noise reduction and sound quality improvements are possible with full vehicle, the countermeasures should be applied at the early design stage. Acoustic holography technology was used to identify the external wind noise sources of a vehicle in Hyundai Aeroacoustic Wind Tunnel. Microphone self-noise reduction techniques and several reference microphone positions are investigated in order to obtain proper results.

  • PDF

Improved Estimation of Leak Location of Pipelines Using Frequency Band Variation (주파수 대역 변화를 이용한 배관의 누수지점 추정 개선 연구)

  • Lee, Young-Sup;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.44-52
    • /
    • 2014
  • Leakage is an important factor to be considered for the management of underground water supply pipelines in a smart water grid system, especially if the pipelines are aged and buried under the pavement or various structures of a highly populated city. Because the exact detection of the location of such leaks in pipelines is essential for their efficient operation, a new methodology for leak location detection based on frequency band variation, windowing filters, and probability is proposed in this paper. Because the exact detection of the leak location depends on the precision of estimation of time delay between sensor signals due to leak noise, some window functions that offer weightings at significant frequencies are applied for calculating the improved cross-correlation function. Experimental results obtained by applying this methodology to an actual buried water supply pipeline, ~ 253.9 m long and made of cast iron, revealed that the approach of frequency band variation with those windows and probability offers better performance for leak location detection.

IMPROVEMENT OF CROSS-CORRELATION TECHNIQUE FOR LEAK DETECTION OF A BURIED PIPE IN A TONAL NOISY ENVIRONMENT

  • Yoon, Doo-Byung;Park, Jin-Ho;Shin, Sung-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.977-984
    • /
    • 2012
  • The cross-correlation technique has been widely used for leakage detection of buried pipes, and this technique can be successfully applied when the leakage signal has a high signal-to-noise ratio. In the case of a power plant, the measured leakage signals obtained from the sensors may contain background noise and mechanical noise generated by adjacent machinery. In such a case, the conventional method using the cross-correlation function may fail to estimate the leakage point. In order to enhance the leakage estimation capability of a buried pipe in a noisy environment, an improved cross-correlation technique is proposed. It uses a noise rejection technique in the frequency domain to effectively eliminate the tonal noise due to rotating machinery. Experiments were carried out to verify the validity of the proposed method. The results show that even in a tonal noisy environment, the proposed method can provide more reliable means for estimating the time delay of the leakage signals.

Leak and Leak Point Prediction by Detecting Negative Pressure Wave in High Pressure Piping System (저압확장파 검출을 통한 배관 누출 및 누출위치 예측)

  • Ha, Tae-Woong;Ha, Jong-Man;Kim, Dong-Hyuk;Kim, Young-Nam
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.47-53
    • /
    • 2007
  • The safe operation of high pressure pipe line systems is of significant importance. Leaks due to faulty operation from the pipelines can lead to considerable product losses and to exposure of community to dangerous gases. There are several leak detection methods, which have been recently suggested on pipeline network. The negative pressure wave detection technology, which has advantages of short time detection availability, accurate leaking location estimate capability and cost effective, is concentrated in this study. Theoretical analysis of the flow characteristics for leaking through a hole on the pipe wall has been performed by using CFD++, commercial CFD package. The results of 3-dimensional analysis near leaking hole confirm the occurrence of negative pressure wave and verify the characteristics of propagation of the wave which travels with speed equal to the speed of sound in the pipeline contents. For the application of long pipe line system. The method of 1-dimensional analysis has been suggested and verified with results of CFD++.

  • PDF