• 제목/요약/키워드: Leak current

검색결과 103건 처리시간 0.029초

345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발 (The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer)

  • 안용호;박종범;송택상;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

균열형상변수의 영향 고찰 (A Study on Influences of Crack Morphology Variables)

  • 박원배;이영신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.324-329
    • /
    • 2004
  • In this study, an application of crack morphology variables in the Leak-Before-Break(LBB) evaluation for nuclear piping systems is investigated, including influences on the leakage crack size and crack instability loads. The crack surface roughness and the number of flow turns as a function of the crack opening displacement are applied to LBB evaluations for KSNP pressurizer surge line, for which fatigue and stress corrosion cracking are considered as failure mechanisms. As a result, there would be a significant impact on safety margins to acceptance criteria for the surge line if crack morphology variables are applied additionally to the current regulatory guide without re-analyses for justification of safety factors being applied on the leakage crack size and piping loads for evaluations.

  • PDF

산업용 표준의 압력시험 방법에 의한 버터플라이 밸브 구성품의 구조해석에 관한 연구 (A Study on Structural Analysis of Butterfly Valve Components by Pressure Testing of the Industrial Standard)

  • 신명섭;윤준용;박인원;이성환;박한영;정승화
    • 한국유체기계학회 논문집
    • /
    • 제14권3호
    • /
    • pp.5-9
    • /
    • 2011
  • Butterfly valves are widely used in current industry to control the fluid flow. They are used for both on-off and throttling applications involving large flows at relatively low pressure-drop especially in large size pipelines. In this study, we carried out the structure analysis of the butterfly valve components according to pressure testing of the industrial standard. the numerical simulation was performed by using ANSYS Workbench. The reliability of valve is evaluated under the investigation of the strain rate, the leak test and the durability of the valve.

사중극 질량 분석기[QMS]를 이용한 미세 농도의 수소기체 분석

  • 임한나;김진태;정수환;강상우;윤주영;신용현
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.331-331
    • /
    • 2010
  • 반도체 제조, 디스플레이 산업 등의 진공공정에서 잔류기체의 종류와 양에 대한 관심이 높아지면서 사용이 쉽고 높은 정확도를 가지는 사중극 질량 분석기(QMS)가 널리 쓰이고 있다. 특히 고진공으로 내려가면서 리크디텍션(leak detection)과 미세량의 잔류기체 감지가 더욱더 요구된다. 그중에서도 진공공정에서의 수소 가스를 감지하는 것은 매우 중요하므로 $H_2$/Ar 혼합가스를 이용하여 미세농도의 수소를 측정하였다. 측정하려는 가스를 부피확장 방법으로 가스챔버로 희석하여 이동시키고 핀홀에서 가스유량을 더 줄여서 QMS가 기체를 감지하는 압력범위를 유지하면서 측정하였다. 미세량의 수소기체를 감지하기 위해 이온소스의 emission current, Ion ref. voltage, cathode voltage의 변수를 조절하여 QMS를 최적화 하였으며, 그 결과 수십 ppm 농도까지 측정이 가능하다.

  • PDF

KSTAR 전류인입선 및 헬륨냉매 제어시스템 제작 및 설치 (Construction and Assembly of KSTAR Current Leads and the Helium Control System)

  • 송낙형;우인식;이영주;곽상우;방은남;이근수;김정수;장용복;박현택;홍재식;박영민;김양수;최창호
    • 한국진공학회지
    • /
    • 제16권5호
    • /
    • pp.388-396
    • /
    • 2007
  • KSTAR (Korea Superconducting Tokamak Advanced Research) 전류인입선(CL; Current Lead)은 4.5 K의 저온에서 운전되는 초전도 버스라인과 300 K의 실온에서 운전되는 MPS (Magnet Power Supply)를 전기적으로 연결하는 장치이다. 초기 플라즈마 발생시험을 위하여 TF (Toroidal Field) 및 PF (Poloidal Field) 리드박스에 전류인입선이 설치된다. TF 자석용 CL은 17.5 kA급 4 개의 CL에 최대 35 kA의 DC 전류가 인가되며, PF 자석용은 13 kA급 14 개의 CL에 350초간 $20\;{\sim}\;26\;kA$의 펄스 전류가 인가된다. 각각의 전류인입선은 TF 및 PF 자석에 전류를 인가하기 위한 버스라인이 연결되어 있으며, 전류인입선을 통해 초전도 버스라인으로 전달되는 전도열 및 전류인가시 발생되는 주울(Joule) 열을 차단하기 위한 헬륨냉매 제어시스템이 KSTAR 주장치와는 별도로 설치되어 있다. 리드박스 내 외부의 배관 및 제어시스템 설치완료 후 고진공 배기, 헬륨 누설검사, 전류인입선 유량 검사 및 액체질소 냉각시험을 실시하여 장치의 성능검증을 완료하였다.

이물질에 대한 ECT Bobbin Probe 검출 감도 (Detection of Foreign Objects Using Bobbin Probe in Eddy Current Test)

  • 정희성;권영호;이동하;신욱조;임찬기
    • 비파괴검사학회지
    • /
    • 제36권4호
    • /
    • pp.295-299
    • /
    • 2016
  • 증기발생기 2차측(관판 상단 및 관 지지판)에 잔류하는 이물질은 전열관에 마모를 야기하여 누설을 발생시킬 가능성이 있으며, 마모는 전열관 재료의 부식 특성과는 별개로 이물질의 재료, 형태, 크기 등에 따라 큰 영향을 받는다. 관판 상단 및 관 지지판 부위의 이물질 여부는 원격육안검사(FOSAR) 방법과 와전류탐상검사(ECT)를 통해 확인하고 있다. 증기발생기 2차측의 잔류 이물질은 그 재질이나 전열관과의 접촉상태 등에 따라 검출하는데 제한성이 나타난다. 따라서, 본 연구에서는 다양한 형태와 재료의 이물질을 관판 상단에서 수직 및 수평한 방향으로 이동시켰을 때, 이물질에 대한 보빈신호의 검출 감도를 측정하기 위해 데이터를 수집하고 분석하였다.

A Ringing Surge Clamper Type Active Auxiliary Edge-Resonant DC Link Snubber-Assisted Three-Phase Soft-Switching Inverter using IGBT-IPM for AC Servo Driver

  • Yoshitsugu, Junji;Yoshida, Masanobu;Hiraki, Eiji;Inoue, Kenji;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권3호
    • /
    • pp.115-124
    • /
    • 2002
  • This paper presents an active auxiliary edge-resonant DC link snubber with a ringing surge damper and a three-phase voltage source type zero voltage soft-switching inverter with the resonat snubber treated here for the AC servo motor driver applications. The operation of the active auxiliary edge-resonant DC link snubber circuit with PWM voltage is described, together with the practical design method to select its circuit parameters. The three-phase voltage source type soft-switching inverter with a single edge-resonant DC link snubber treated here is evaluated and discussed for the small-scale permanent magnet (PM) type-AC servo motor driver from an experimental point of view. In addition to these, the AC motor stator current and its motor speed response for the proposed three-phase soft-switching inverter employing Intelligent Power Module(IPM) based on IGBTS are compared with those of the conventional three-phase hard-switching inverter using IPM. The practical effectiveness of the three-phase soft-switching inverter-fed permanent magnet type AC motor speed tracking servo driver is proven on the basis of the common mode current in a novel type three-phase soft-switching inverter-fed AC motor side and the conductive noise on the mains terminal interface voltage as compared with those of the conventional three-phase hard-switching inverter-fed permanent magnet type AC servo motor driver for the speed tracking applications.

누출사고 시 저장탱크 위험물 누출속도를 고려한 방유제 설계에 관한 연구 (A Study of a Dike Design Considering a Leakage Velocity at an Opening Hole in Case of a Leakage Accident)

  • 이재열;김동현;반순희;이창준
    • 한국안전학회지
    • /
    • 제32권6호
    • /
    • pp.40-45
    • /
    • 2017
  • Chemical accidents generated during maintenance, repair, and normal operation, such as dispersion, fire, and explosions, can cause massive losses like a 2012 hydro fluorine leak in Gumi, South Korea. Since this accident, many researches have studied physical mitigation systems. However, due to many difficulties including potential costs and lack time, it is really hard for many companies to install mitigation systems without prior knowledge. Thus, the efficacy of mitigation system should be evaluated. This study assesses a dike design considering the fluid velocity at an open hole when a leakage accident occurs. It is assumed that leakage materials follow a free fall motion. Throughout case studies, a current KOSHA guide for a dike design was evaluated and new guidelines handling various conditions were proposed.

누출사고 시 저장탱크 위험물 누출속도를 고려한 탱크와 방유제 사이 간격에 관한 연구 (A Study of the Distance between a Tank and a Dike Considering a Leakage Velocity at an Opening Hole in case of a Leakage Accident)

  • 이재열;김동현;반순희;이창준
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.35-41
    • /
    • 2018
  • Chemical accidents generated during maintenance, repair, and normal operation, such as dispersion, fire, and explosions, can cause massive losses like a 2012 hydro fluorine leak in Gumi, South Korea. Since this accident, many researches have studied physical mitigation systems. However, due to the lack of potential costs and time, it is really hard for many companies to install mitigation systems without prior knowledge. Thus, the efficacy of mitigation system should be evaluated. This study assesses a dike design considering the fluid velocity at an open hole when a leakage accident occurs. It is assumed that leakage materials follow a free fall motion. Throughout case studies, a current KOSHA guide for a dike design was evaluated and new guidelines handling various conditions were proposed.

Stellar populations of Galactic Globular Cluster $\omega$ Cen using HST/WFC3 near-UV observations

  • 김은혁;주석주;이영욱
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.54.2-54.2
    • /
    • 2010
  • The most massive galactic globular cluster, $\omega$ Cen has been observed using recently mounted WFC3/UVIS cameras of Hubble Space Telescope at both near-UV and optical bands. We present the photometry of stars in the central region of $\omega$ Cen in F225W, F275W and F336W bands. The near-UV color-magnitude diagrams and color-color diagrams of stars in $\omega$ Cen show multiple red giant branches and main sequences as already discovered in both ground-based and HST/ACS observations in the optical bands. We modelled the stellar populations of $\omega$ Cen using Yonsei Isochrone, where $\alpha$-particles and helium enhancement processes have been included properly. We compare the best-fit stellar populations obtained from the current near-UV observations to the suggested stellar population models based on optical band data. We also discuss the methodological issues arising when dealing with the near-UV observations; red-leak in near-UV filters and the huge interstellar extinction in near-UV bands compared to the optical bands and its non-linear effect in color-magnitude diagrams.

  • PDF