The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer (345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발)

  • An, Y.H.;Park, J.B.;Song, T.S.;Han, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

A Study on Influences of Crack Morphology Variables (균열형상변수의 영향 고찰)

  • Park, Won-Bae;Lee, Young-Shin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.324-329
    • /
    • 2004
  • In this study, an application of crack morphology variables in the Leak-Before-Break(LBB) evaluation for nuclear piping systems is investigated, including influences on the leakage crack size and crack instability loads. The crack surface roughness and the number of flow turns as a function of the crack opening displacement are applied to LBB evaluations for KSNP pressurizer surge line, for which fatigue and stress corrosion cracking are considered as failure mechanisms. As a result, there would be a significant impact on safety margins to acceptance criteria for the surge line if crack morphology variables are applied additionally to the current regulatory guide without re-analyses for justification of safety factors being applied on the leakage crack size and piping loads for evaluations.

  • PDF

A Study on Structural Analysis of Butterfly Valve Components by Pressure Testing of the Industrial Standard (산업용 표준의 압력시험 방법에 의한 버터플라이 밸브 구성품의 구조해석에 관한 연구)

  • Shin, Myung-Seob;Yoon, Joon-Yong;Park, In-Won;Lee, Seoung-Hwan;Park, Han-Yung;Jung, Seung-Hwa
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.5-9
    • /
    • 2011
  • Butterfly valves are widely used in current industry to control the fluid flow. They are used for both on-off and throttling applications involving large flows at relatively low pressure-drop especially in large size pipelines. In this study, we carried out the structure analysis of the butterfly valve components according to pressure testing of the industrial standard. the numerical simulation was performed by using ANSYS Workbench. The reliability of valve is evaluated under the investigation of the strain rate, the leak test and the durability of the valve.

사중극 질량 분석기[QMS]를 이용한 미세 농도의 수소기체 분석

  • Im, Han-Na;Kim, Jin-Tae;Jeong, Su-Hwan;Gang, Sang-U;Yun, Ju-Yeong;Sin, Yong-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.331-331
    • /
    • 2010
  • 반도체 제조, 디스플레이 산업 등의 진공공정에서 잔류기체의 종류와 양에 대한 관심이 높아지면서 사용이 쉽고 높은 정확도를 가지는 사중극 질량 분석기(QMS)가 널리 쓰이고 있다. 특히 고진공으로 내려가면서 리크디텍션(leak detection)과 미세량의 잔류기체 감지가 더욱더 요구된다. 그중에서도 진공공정에서의 수소 가스를 감지하는 것은 매우 중요하므로 $H_2$/Ar 혼합가스를 이용하여 미세농도의 수소를 측정하였다. 측정하려는 가스를 부피확장 방법으로 가스챔버로 희석하여 이동시키고 핀홀에서 가스유량을 더 줄여서 QMS가 기체를 감지하는 압력범위를 유지하면서 측정하였다. 미세량의 수소기체를 감지하기 위해 이온소스의 emission current, Ion ref. voltage, cathode voltage의 변수를 조절하여 QMS를 최적화 하였으며, 그 결과 수십 ppm 농도까지 측정이 가능하다.

  • PDF

Construction and Assembly of KSTAR Current Leads and the Helium Control System (KSTAR 전류인입선 및 헬륨냉매 제어시스템 제작 및 설치)

  • Song, N.H.;Woo, I.S.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, J.S.;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.388-396
    • /
    • 2007
  • KSTAR (Korea Superconducting Tokamak Advanced Research) current lead system (CLS) has a role to interconnect magnet power supply (MPS) in room temperature (300 K) and superconducting (SC) bus-line, electrically. For the first plasma experiments, it should be assembled 4 current leads (CL) on toroidal field (TF) current lead box (CLB) and 14 leads on poloidal field (PF) CLB. Two current leads, with the design currents 17.5 kA, and SC bus-lines are connected in parallel to supply 35 kA DC currents on TF magnet. Whereas, it could supply $20\;{\sim}\;26\;kA$ to each pairs of PF magnets during more than 350 s. At the cold terminals of the leads, there are joined SC bus-lines and it was constructed helium coolant control system, aside from main tokamak system, to protect heat flux through current leads and enhanced Joule heat due to supplied currents. Throughout the establishment processes, it was tested the high vacuum pumping, helium leak of the helium lines and hardwares mounted between the helium lines, flow controls for CL, and liquid nitrogen cool-down of possible parts (current leads, CL helium lines, and thermal shield helium lines for CLB), for the accomplishment of the required performances.

Detection of Foreign Objects Using Bobbin Probe in Eddy Current Test (이물질에 대한 ECT Bobbin Probe 검출 감도)

  • Jung, Hee-Sung;Kweon, Young-Ho;Lee, Dong-Ha;Shin, Wook-Jo;Yim, Chan-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.295-299
    • /
    • 2016
  • Residual foreign objects at the secondary side (top of the tubesheet and tube support plates) of a steam generator are likely to cause a leak by causing wear in the tube. The extent of wear is significantly affected by the material, shape, and size of the foreign object, and the corrosion properties of the tube. The presence of foreign objects at the top of the tubesheet and tube support plates has been identified using remote visual inspection methods such as the foreign object search and retrieval and eddy current test (ECT). The detection of the residual foreign object at the secondary side of a steam generator has limitations that depend on the material properties and the condition of contact with the tube. In this study, which is vertical and horizontal from the upper tubesheet, the corresponding bobbin ECT signals were collected and analyzed to measure its ability to detect foreign objects.

A Ringing Surge Clamper Type Active Auxiliary Edge-Resonant DC Link Snubber-Assisted Three-Phase Soft-Switching Inverter using IGBT-IPM for AC Servo Driver

  • Yoshitsugu, Junji;Yoshida, Masanobu;Hiraki, Eiji;Inoue, Kenji;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.115-124
    • /
    • 2002
  • This paper presents an active auxiliary edge-resonant DC link snubber with a ringing surge damper and a three-phase voltage source type zero voltage soft-switching inverter with the resonat snubber treated here for the AC servo motor driver applications. The operation of the active auxiliary edge-resonant DC link snubber circuit with PWM voltage is described, together with the practical design method to select its circuit parameters. The three-phase voltage source type soft-switching inverter with a single edge-resonant DC link snubber treated here is evaluated and discussed for the small-scale permanent magnet (PM) type-AC servo motor driver from an experimental point of view. In addition to these, the AC motor stator current and its motor speed response for the proposed three-phase soft-switching inverter employing Intelligent Power Module(IPM) based on IGBTS are compared with those of the conventional three-phase hard-switching inverter using IPM. The practical effectiveness of the three-phase soft-switching inverter-fed permanent magnet type AC motor speed tracking servo driver is proven on the basis of the common mode current in a novel type three-phase soft-switching inverter-fed AC motor side and the conductive noise on the mains terminal interface voltage as compared with those of the conventional three-phase hard-switching inverter-fed permanent magnet type AC servo motor driver for the speed tracking applications.

A Study of a Dike Design Considering a Leakage Velocity at an Opening Hole in Case of a Leakage Accident (누출사고 시 저장탱크 위험물 누출속도를 고려한 방유제 설계에 관한 연구)

  • Lee, Jae Yeol;Kim, Dong Hyun;Ban, Soon Hee;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.40-45
    • /
    • 2017
  • Chemical accidents generated during maintenance, repair, and normal operation, such as dispersion, fire, and explosions, can cause massive losses like a 2012 hydro fluorine leak in Gumi, South Korea. Since this accident, many researches have studied physical mitigation systems. However, due to many difficulties including potential costs and lack time, it is really hard for many companies to install mitigation systems without prior knowledge. Thus, the efficacy of mitigation system should be evaluated. This study assesses a dike design considering the fluid velocity at an open hole when a leakage accident occurs. It is assumed that leakage materials follow a free fall motion. Throughout case studies, a current KOSHA guide for a dike design was evaluated and new guidelines handling various conditions were proposed.

A Study of the Distance between a Tank and a Dike Considering a Leakage Velocity at an Opening Hole in case of a Leakage Accident (누출사고 시 저장탱크 위험물 누출속도를 고려한 탱크와 방유제 사이 간격에 관한 연구)

  • Lee, Jae Yeol;Kim, Dong Hyun;Ban, Soon Hee;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.35-41
    • /
    • 2018
  • Chemical accidents generated during maintenance, repair, and normal operation, such as dispersion, fire, and explosions, can cause massive losses like a 2012 hydro fluorine leak in Gumi, South Korea. Since this accident, many researches have studied physical mitigation systems. However, due to the lack of potential costs and time, it is really hard for many companies to install mitigation systems without prior knowledge. Thus, the efficacy of mitigation system should be evaluated. This study assesses a dike design considering the fluid velocity at an open hole when a leakage accident occurs. It is assumed that leakage materials follow a free fall motion. Throughout case studies, a current KOSHA guide for a dike design was evaluated and new guidelines handling various conditions were proposed.

Stellar populations of Galactic Globular Cluster $\omega$ Cen using HST/WFC3 near-UV observations

  • Kim, Eun-Hyeuk;Joo, Seok-Joo;Lee, Young-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.54.2-54.2
    • /
    • 2010
  • The most massive galactic globular cluster, $\omega$ Cen has been observed using recently mounted WFC3/UVIS cameras of Hubble Space Telescope at both near-UV and optical bands. We present the photometry of stars in the central region of $\omega$ Cen in F225W, F275W and F336W bands. The near-UV color-magnitude diagrams and color-color diagrams of stars in $\omega$ Cen show multiple red giant branches and main sequences as already discovered in both ground-based and HST/ACS observations in the optical bands. We modelled the stellar populations of $\omega$ Cen using Yonsei Isochrone, where $\alpha$-particles and helium enhancement processes have been included properly. We compare the best-fit stellar populations obtained from the current near-UV observations to the suggested stellar population models based on optical band data. We also discuss the methodological issues arising when dealing with the near-UV observations; red-leak in near-UV filters and the huge interstellar extinction in near-UV bands compared to the optical bands and its non-linear effect in color-magnitude diagrams.

  • PDF