• Title/Summary/Keyword: Leak Monitoring System

Search Result 65, Processing Time 0.033 seconds

A Presentation in the Nuclear Steam Supply System Integrity Monitoring System (NIMS) for Yonggwang Nuclear Power Plant, Units 3&4 (영광원자력발전소 3,4호기 핵증기 공급계통(NSSS)의 종합건전성 감시계통의 신기술 소개)

  • 장우현;최찬덕;김성호;한상준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.81-86
    • /
    • 1992
  • 원자력발전소 1차 계통 내의 건전성 감시를 위한 설비로는 음향누설 감시계 통(Acoustic Leak Monitoring System: ALMS), 금속파편 감시계통(Loose Parts Monitoring System: LPMS) 및 원자로내부구조물 진동감시계통 (Internals Vibration Monitoring System: IVMS)등이 있다. 현재, 국내의 여 러 원전에는 이들중 일부 계통들이 선택적으로 설치되어 운전중이며, 영광 3,4호기에서는 국내 최초로 이들 3개의 계통을 종합한 핵증기공급계통 건전 성감시계통(Nuclear Steam Supply System Integrity Monitoring System: NIMS)을 설계하였다. 특히, 영광 3,4호기 NIMS에서는 각 계통에 의해 감지 된 1차 계통 내의 이상상태를 하나의 분석컴퓨터(Analysis Computer)를 사 용하여 해석하는 종합결함 탐지해석 기법을 도입하였다.

  • PDF

Location Estimation Method of Steam Leak in Pipelines Using Leakage Area Analysis (누설영역 분석을 이용한 배관 증기누설 위치 추정 방법)

  • Kim, Se-Oh;Jeon, Hyeong-Seop;Son, Ki-Sung;Park, Jong Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.384-390
    • /
    • 2016
  • It is important to have a pipeline leak-detection system that determines the presence of a leak and quickly identifies its location. Current leak detection methods use a acoustic emission sensors, microphone arrays, and camera images. Recently, many researchers have been focusing on using cameras for detecting leaks. The advantage of this method is that it can survey a wide area and monitor a pipeline over a long distance. However, conventional methods using camera monitoring are unable to target an exact leak location. In this paper, we propose a method of detecting leak locations using leak-detection results combined with multi-frame analysis. The proposed method is verified by experiment.

Automatic Meter Reading System for Water-Supply (상수도 자동 검침 시스템 구축에 관한 연구 : 부산 기장군과 김해시 사례를 중심으로)

  • Seo, Chang-Gab;Park, Young-Jae
    • Journal of Digital Convergence
    • /
    • v.7 no.3
    • /
    • pp.103-111
    • /
    • 2009
  • In this paper, we introduce automatic meter reading system for tap water. The system is composed of automatic meter, router using RF and CDMA network, and data server. This system will easily extend to fire detect, gas, and electric charge meter system. In addition, this system will be used to monitoring a water leak and human which live in solitude. Proposed system is installed at Gimhae-City and Gijang-gun. As a result of the automatic meter reading system for tap water, The leak of water and complain of user is decreased. But The building cost is still an obstacle to expand into entire city.

  • PDF

Acoustic Emission (AE) Technology-based Leak Detection System Using Macro-fiber Composite (MFC) Sensor (Macro fiber composite (MFC) 센서를 이용한 음향방출 기술 기반 배관 누수 감지 시스템)

  • Jaehyun Park;Si-Maek Lee;Beom-Joo Lee;Seon Ju Kim;Hyeong-Min Yoo
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.429-434
    • /
    • 2023
  • In this study, aimed at improving the existing acoustic emission sensor for real time monitoring, a macro-fiber composite (MFC) transducer was employed as the acoustic emission sensor in the gas leak detection system. Prior to implementation, structural analysis was conducted to optimize the MFC's design. Consequently, the flexibility of the MFC facilitated excellent adherence to curved pipes, enabling the reception of acoustic emission (AE) signals without complications. Analysis of AE signals revealed substantial variations in parameter values for both high-pressure and low-pressure leaks. Notably, in the parameters of the Fast Fourier Transform (FFT) graph, the change amounted to 120% to 626% for high-pressure leaks compared to the case without leaks, and approximately 9% to 22% for low-pressure leaks. Furthermore, depending on the distance from the leak site, the magnitude of change in parameters tended to decrease as the distance increased. As the results, in the future, not only will it be possible to detect a leak by detecting the amount of parameter change in the future, but it will also be possible to identify the location of the leak from the amount of change.

Use of In-Situ Optical Emission Spectroscopy for Leak Fault Detection and Classification in Plasma Etching

  • Lee, Ho Jae;Seo, Dong-Sun;May, Gary S.;Hong, Sang Jeen
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.4
    • /
    • pp.395-401
    • /
    • 2013
  • In-situ optical emission spectroscopy (OES) is employed for leak detection in plasma etching system. A misprocessing is reported for significantly reduced silicon etch rate with chlorine gas, and OES is used as a supplementary sensor to analyze the gas phase species that reside in the process chamber. Potential cause of misprocessing reaches to chamber O-ring wear out, MFC leaks, and/or leak at gas delivery line, and experiments are performed to funnel down the potential of the cause. While monitoring the plasma chemistry of the process chamber using OES, the emission trace for nitrogen species is observed at the chlorine gas supply. No trace of nitrogen species is found in other than chlorine gas supply, and we found that the amount of chlorine gas is slightly fluctuating. We successfully found the root cause of the reported misprocessing which may jeopardize the quality of thin film processing. Based on a quantitative analysis of the amount of nitrogen observed in the chamber, we conclude that the source of the leak is the fitting of the chlorine mass flow controller with the amount of around 2-5 sccm.

Performance Evaluation Monitoring System of EURO5 Type Valve for Overflow (EURO5형 오버플로어 밸브 성능평가 모니터링 시스템 구현)

  • Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.17 no.1
    • /
    • pp.57-62
    • /
    • 2013
  • In this paper, we have implemented an overflow valve for EURO5 Type and the performance evaluation system based on IEEE802 protocol. On injecting a diesel oil into an engine, it is necessity for an overflow valve that can sustain an engine oil status in front of the engine. In order to evaluate the performance of overflow valve, we need the leak test system with IT. The leak test system checks the pressure, switching time and operating time.

Improved Integrated Monitoring System Design and Construction (개선된 통합모니터링 시스템 설계 및 구축)

  • Jeon, Byung-Jin;Yoon, Deok-Byeong;Shin, Seung-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.1
    • /
    • pp.25-33
    • /
    • 2017
  • In order to prevent information leakage, companies are monitoring the information leakage by internal staff by building individual security system and integrated monitoring system of firewall and DLP function. Especially, many log data of the integrated monitoring system cause time and money, and it is difficult to detect information leak of fast malicious personnel due to system slowdown. It is necessary to speed up the system by digitizing large log data for each day and person for fast information leakage detection and there is a need to develop and manage a continuous monitoring program for the information leakage indications personnel. Therefore, we propose an improved integrated monitoring system using log data by date and individual data.

Method to Analyze Information Leakage Malware using SSL Communication in Android Platform

  • Cho, Gilsu;Kim, Sangwho;Ryou, Jaecheol
    • Journal of Internet Computing and Services
    • /
    • v.19 no.3
    • /
    • pp.1-6
    • /
    • 2018
  • Widely used around the world, smartphones contain many features and can store content such as contacts, photos, and videos. Information that can be leaked in proportion to the information that the smartphone can store has also been increased. In recent years, accidents such as personal information leakage have occurred frequently. Personal information leakage is happening in the Android environment, which accounts for more than half of the smartphone operating system market share. Analyzing malicious apps that leak information can tell you how to prevent information leakage. Malicious apps that leak information will send importantinformation to the hacker's (C & C) server, which will use network communication. Malicious apps that are emerging nowadays encrypt and transmit important information through SSL communication. In this case, it is difficult to knowwhat kind of information is exposed to network. Therefore, we suggest a method to analyze malicious apps when leak important information through SSL communication. In this paper, we identify the way malicious apps leak information. And we propose a method for analyzing information leaked by SSL communication. Data before encryption was confirmed in the device through SSL hooking and SSL Strip method.

Risk Assessment for Abolition of Gross Containment Leak Monitoring System Test in CANDU Design Plant (중수로 원자로건물 총누설감시계통 시험 중지에 따른 리스크 영향 평가)

  • Bae, Yeon-Kyoung;Na, Jang-Hwan;Bahng, Ki-In
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.123-130
    • /
    • 2015
  • Wolsong Unit 2,3&4 has been performing a containment integrity test during power operation. This test could impact to the safe operation during test. If an accident occurs during pressure dropping phase, reactor trip can be delayed because of the increased pressure difference which causes a time delay to reach the trip set-point. On the contrary, if an accident occurs during pressure increasing phase, reactor trip could be accelerated because the pressure difference to the trip set-point decrease. Point Lepreau nuclear power plant, which installed GCLMS (Gross Containment Leakage Monitoring System) in 1990, has discontinued the test since 1992 due to these adverse effects. Therefore, we evaluated the risk to obviate the GCLMS test based on PWR's ILRT (Integrated Leak Rate Test) extension methodologies. The results demonstrate that risk increase rate is not high in case of performing only ILRT test at every 5 years instead of doing GCLMS test at every 1.5 years. In addition, the result shows that GCLMS test can be removed on a risk-informed perspective since risk increasement is in acceptable area of regulatory acceptance criteria.