• Title/Summary/Keyword: Lead Selenide

Search Result 6, Processing Time 0.024 seconds

Enhanced field emission properties of double-walled carbon nanotubes coated with lead selenide nanoparticles (셀렌화납 코팅을 통한 이중벽 탄소나노튜브의 전계방출특성 향상)

  • Shin, Dong-Hoon;Lee, Cheol-Jin;Choi, Young-Min;Kim, Jong-Ung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.594-598
    • /
    • 2010
  • We studied on the field emission properties of double-walled carbon nanotubes (DWCNTs) coated with lead selenide (PbSe) nanoparticles. PbSe nanoparticles were uniformly attached on the surface of the DWCNTs by a simple chemical process. The PbSe-coated DWCNTs showed highly increased emission current density and enhanced emission stability over 20 h, compared with raw DWCNTs. We consider that the enhanced field emission properties of PbSe-coated DWCNTs were attributed to the increased field enhancement factor and lowered work function of the emitters.

Surface Characterization of Zinc Selenide Thin Films Obtained by RF co-sputtering

  • Lee, Seokhee;Kang, Jisoo;Park, Juyun;Kang, Yong-Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.66 no.5
    • /
    • pp.341-348
    • /
    • 2022
  • In this work, radio frequency magnetron sputtering was used to deposit zinc selenide thin films on p-type silicon (100) wafers and glass substrates in a high vacuum chamber. Several surface characterization instruments were implemented to study the thin films. X-ray photoelectron spectroscopy results revealed that oxidized Zn bound to Se (Zn-Se) at 1022.7 ± 0.1 eV becomes the dominant oxidized species when Se concentration exceeds 70%. Scanning electron microscopy coupled with energy dispersive spectroscopy showed that incorporating Se in Zn thin films will lead to formation of ZnSe grains on the surface. Contact angle measurements indicated that ZnSe-60 exhibited the lowest total surface free energy value of 24.94 mN/m. Lastly, ultraviolet-visible spectrophotometry and ultraviolet photoelectron spectroscopy data evinced that the energy band gap gradually increases with increasing Se concentration with ZnSe-70 having the highest work function value of 4.91 eV.

Development of Fast-Response Portable NDIR Analyzer Using Semiconductor Devices

  • Kim, Woo-Seok;Lee, Jong-Hwa;Park, Young-Moo;Yoo, Jai-Suk;Park, Kyoung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2099-2106
    • /
    • 2003
  • In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO$_2$) at a wavelength of 4.28 $\mu\textrm{m}$, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO$_2$ gas measurement and, in particular, the measurement of fast response CO$_2$ concentration at millisecond level.

Colloidal Synthesis of Octahedral Shaped PbSe Nanocrystals from Lead Oleate and Se : Temperature Effect

  • Gokarna, Anisha;Jun, Ki-Won;Khanna, P.K.;Baeg, Jin-Ook;Seok, Sang-Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.11
    • /
    • pp.1803-1806
    • /
    • 2005
  • Formation of octahedral shaped PbSe quantum dots at higher synthesis temperature is being reported in this paper. The synthesis includes the reaction between lead oleate and trioctylphosphine selenide under inert gas conditions to produce PbSe. TEM, SEM, XRD and EDS were used to characterize the samples. The SEM exhibited the formation of spherical shaped nanocrystals at temperature below 140 ${^{\circ}C}$ and octahedral shaped nanoparticles at higher temperatures. Moreover, the TEM also showed the well resolved (111) lattice fringes proving that the nanocrystals were crystalline in nature. Synthesis of highly pure PbSe nanocrystals was another interesting aspect of this research.

Synthesis of Lead Selenide Nanowires by Photolithography and Electrodeposition Process (포토리소그래피와 도금을 사용한 셀레늄화 납 나노와이어 합성)

  • Song, Yeong-Seop;Lee, Ju-Yeol;Lee, Gyu-Hwan;Im, Jae-Hong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.305-305
    • /
    • 2014
  • 포토리소그래피와 도금 공정을 통해 PbSe 나노와이어를 합성하였다. PbSe은 광센서 및 열전 물질로 많이 알려져있다. 이러한 응용처에의 향상된 성능을 위해 본 연구에서는 PbSe 나노와이를 합성하였다. 합성에 사용된 방법인 포토리소그래피와 도금 공정은 반도체 산업 전반에 인프라가 잘 구축된 공정이며, 병렬 공정이다. 따라서 본 연구는 경제적이며 대량생산이 가능한 PbSe 나노와이어의 합성법을 제안한다.

  • PDF

Development and Properties of Carbon monoxide Detector for Ambient Air monitoring (대기오염 측정용 일신화 탄소 검출기의 제작 및 특성)

  • Cho, Kyung-Haeng;Lee, Sang-Wha;Lee, Joung-Hae;Choi, Kyong-Sik
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.222-228
    • /
    • 2000
  • A detector for monitoring carbon monoxide (CO) in ambient air by nondispersive infrared (NDIR) spectroscopy has been developed and investigated its sensitivity and stability. The essential parts of the absorption cell are three spherical concave mirrors so as to improve the sensitivity by increasing the light path length in the cell. The radius and center of curvature of mirrors and position in the cell was calculated by computer simulation in order that the light path length may be 16m into the 50cm cell. The number of traversals and optical path properties were confirmed by laser beam alignment in transparent absorption cell. The photoconductive type lead selenide (PbSe) was used as CO sensing material, which was cooled to increase the responsibility by thermoelectric cooling method. The detection limit and span drift of the developed CO detector was 0.24ppm and 0.03ppm(v/v) respectively.

  • PDF