• 제목/요약/키워드: Lead Ions

검색결과 232건 처리시간 0.025초

분말 소나무 수피를 이용한 수용액 중의 납 이온 흡착 (Adsorption of Lead Ions from Aqueous Solutions Using Milled Pine Bark)

  • 오미영;김영관
    • 상하수도학회지
    • /
    • 제20권3호
    • /
    • pp.389-395
    • /
    • 2006
  • The use of pine bark, a natural adsorbent prepared from Korean Red Pine (Pinus densifloral), was studied for its adsorption behavior of lead ion from aqueous solution. Adsorption experiments were carried out on lead ion concentrations of 10mg/L. Adsorption of lead ion could be described by both Langmuir and Freundlich adsorption isotherms. Treatment of the bark with nitric acid greatly increased initial adsorption rate, and equilibrium sorption capacity increased by approximately 48%. A pseudo second-order kinetic model fitted well for the kinetic behavior of lead ion adsorption onto the bark. Acid-treated bark demonstrated its adsorption capacity quite close to that of granular activated carbon. Results of this study indicated that ion exchange and chelation were involved in the adsorption process.

Simultaneous Determination of Tin, Nickel, Lead, Cadmium and Mercury in Cigarette Material by Solid Phase Extraction and HPLC

  • Hu, Qun;Yang, Guangyu;Ma, Jing;Liu, Jikai
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권10호
    • /
    • pp.1433-1436
    • /
    • 2003
  • A new method for the simultaneous determination of heavy metal ions in cigarette material by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The cigarette material was digested by microwave digestion. Lead, cadmium, mercury, nickel and tin ions in the digested samples were pre-column derivatized with tetra-(2-chlorophenyl)-porphyrin ($T_2$-CPP) to form color chelates, which were then enriched by solid phase extraction with a $C_{18}$ cartridge. The chelates were separated on a Waters Xterra$^{TM}RP_{18}$ column by gradient elution with methanol (containing 0.05 mol/L pyrrolidine-aceticacid buffer salt, pH = 10.0) and acetone (containin0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0)as mobile phase at a flow rate of 0.5mL/min and analyzed with a photodiode array detector from 350-600 nm. The detection limits of lead, cadmium, mercury, nickel and tin were 4,3,3,8 and 5 ng/L, respectively, in the original samples. This method was afforded good results.

골탄(bone char)의 중금속 제거 특성에 관한 연구 (A Study on Heavy Metal Removal Characteristics Using Bone Char)

  • 김재영;김환기
    • 상하수도학회지
    • /
    • 제21권2호
    • /
    • pp.253-258
    • /
    • 2007
  • The adsorption capacity of bone char for lead, cadmium and zinc was studied in both single and binary multiple component systems. Equilibrium experimental studies have been performed to determine the sorption capacity of bone char for each metal ion. These have been analysed using single and multi-component equilibrum models. The results show that the sorption of metal ions for multi-component systems can be predicted reasonably well from the IAS theory with the Langmuir equation, the Freundlich and the Slip equation for metal ions.

Metal Ion Dissolution in Nitric Acid with Lead-Borosilicate Glass for Barrier Ribs in PDP

  • Kim, Jae-Myung;Lee, Chong-Mu;Kim, Hyung-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1252-1254
    • /
    • 2005
  • Recently, PDP barrier ribs require the formation of complex structure so that they are usually formed by etching method. For producing the fine ribs structure, during the etching process the metal ions of matrix (glass) of barrier materials should be understood on the etching mechanism with etching condition. We analyzed the quantity of Pb, Si, and B ions from the etch solution as a function of etching time.

  • PDF

카드뮴과 납 전기화학적 검출을 위한 전극선정에 관한 연구 (Study on Electrode Selection for Electrochemical Detection of Cadmium and Lead)

  • 김학진;김기영;모창연;조한근
    • Journal of Biosystems Engineering
    • /
    • 제33권6호
    • /
    • pp.404-409
    • /
    • 2008
  • Excessive presence of heavy metals in environment affects plants and fruits grown in the contaminated area. Rapid on-site monitoring of heavy metals can provide useful information for efficiently characterizing heavy metal-contaminated sites and for minimizing the exposure of the contaminated food crops to humans. This study reports on the evaluation of gold and glassy carbon (GC) electrodes with mercury or bismuth as a coating material for simultaneous determination of cadmium (Cd) and lead (Pb) in 0.1 M $HNO_3$ solution by anodic stripping voltammetry (ASV). The use of a square-wave voltammetric potential between a working electrode and a reference electrode caused Cd and Pb ions deposited on the electrode surface to be oxidized, thereby generating electric currents at different potentials. The mercury-coated gold electrode was not sensitive enough to detect the usable range of Cd concentrations (1 to 100 ppb). The GC electrodes with mercury or bismuth displayed well-defined, sharp and separate current peaks for Cd and Pb ions when the square-wave voltammetric potentials were applied. The peak currents measured with both mercury- and bismuth- coated GC electrodes were linearly proportional to Cd and Pb concentrations in the range of 1 to 200 ppb in 0.1 M $HNO_3$ with strong linear relationships between concentration and peak current ($R^2$ > 0.95), indicating that both of Cd and Pb ions could be quantitatively measured.

Synthesis and Crystal Structure of Lead Iodide in the Sodalite Cavities of Zeolite A (LTA)

  • Kim, Seok-Han;Lim, Woo-Taik;Kim, Ghyung-Hwa;Lee, Heung-Soo;Heo, Nam-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권5호
    • /
    • pp.679-686
    • /
    • 2006
  • The positions of $PbI _2$ molecule synthesized into the molecular-dimensioned cavities of $\mid K_6 (Pb _4I_2)(PbI_2) _{0.67}-(H_2O)_2\mid [Si _{12}Al _{12}O _{48}]$-LTA have been determined. A single crystal of $\mid Pb _6\mid [Si _{12}Al _{12}O _{48}]$-LTA, prepared by the dynamic ion-exchange of $\mid Na _{12}\mid [Si _{12}Al _{12}O _{48}]$-LTA with aqueous 0.05 M $Pb _(NO _3)_2$ and washed with deionized water, was placed in a stream of flowing aqueous 0.05 M KI at 294 K for three days. The resulting crystal structure of the product $( \mid K_6 (Pb _4I_2)(PbI_2) _{0.67}(H_2O)_2\mid [Si _{12}Al _{12}O _{48}]$-LTA, a = 12.353(1) $\AA$) was determined at 294 K by single-crystal X-ray diffraction in the space group Pm3 m. It was refined with all measured reflections to the final error index $R_1$ = 0.062 for 623 reflections which $F_o$ > 4$\sigma$($F_o$). 4.67 $Pb ^{2+}$ and six $K^+$ ions per unit cell are found at three crystallographically distinct positions: 3.67 $Pb ^{2+}$ and three $K^+$ ions on the 3-fold axes opposite six-rings in the large cavity, three $K^+$ ions off the plane of the eight-rings, and the remaining one $Pb ^{2+}$ ion lies opposite four-ring in the large cavity. 0.67 $Pb ^{2+}$ ions and 1.34 $I^-$ ions per unit cell are found in the sodalite units, indicating the formation of a $PbI _2$ molecule in 67% of the sodalite units. Each $PbI _2$ (Pb-I = 3.392(7) $\AA$) is held in place by the coordination of its one $Pb ^{2+}$ ion to the zeolite framework (a $Pb ^{2+}$ cation is 0.74 $\AA$ from a six-ring oxygens) and by the coordination of its two $I^-$ ions to $K^+$ ions through six-rings (I-K = 3.63(4) $\AA$). Two additional $I^-$ ions per unit cell are found opposite a four-ring in the large cavity and form $Pb _2K_2I^{5+}$ and $Pb _2K_2I^{3+}$ moieties, respectively, and two water molecules per unit cell are also found on the 3-fold axes in the large cavity.

Fixed bed column modeling of lead(II) and cadmium(II) ions biosorption on sugarcane bagasse

  • Vera, Luisa Mayra;Bermejo, Daniel;Uguna, Maria Fernanda;Garcia, Nancy;Flores, Marittza;Gonzalez, Enrique
    • Environmental Engineering Research
    • /
    • 제24권1호
    • /
    • pp.31-37
    • /
    • 2019
  • In this paper the results of the biosorption of lead(II) and cadmium(II) with sugarcane bagasse in fixed bed columns are presented. Experimental data were fitted to several models describing the rupture curve for single-component and two-component systems. The percentages of removal of lead and cadmium in single-component systems are 91% and 90%, respectively. In lead-cadmium bicomponent systems the percentage of elimination of lead was 90% and cadmium 92%. In single-component systems, Yoon-Nelson and Thomas models successfully reproduce the rupture curves. In two-component system, the Dose-Response model was the best one reproducing the experimental rupture curves in the entire measured range.

초산납이 흰쥐 synaptosome의 [$^3$H]-serotonin의 흡수에 미치는 영향 (Effects of Lead Acetate on the Uptake of [$^3$H]-serotonin by the Synaptosomes Separated from the Cerebrum and Brain Stem of the Rat)

  • 이규석;박순철
    • 환경생물
    • /
    • 제18권2호
    • /
    • pp.255-262
    • /
    • 2000
  • Synaptosome에 의한 [$^3$H]-serotonin의 일반적인 흡수특성과 이 과정에 납이 미치는 영향을 in vitro와 in vitro에서 관찰하였다. 흰쥐의 대뇌와 뇌간에서 각각 분리한 synaptosome의 흡수친화력은 대뇌가 Km=0.5$\mu$M, 뇌간이 Km=0.1$\mu$M로 모두 고친화성 흡수였고 뇌간에서 더 높았다. 또한 이 흡수과정에 sodium과 potassium이온이 영향을 미치는 것으로 나타났다. Synaptosome이 [$^3$H]-serotonin을 흡수하는 과정은 납에 의해 억제되었고 이러한 납의 독성영향은 in vitro와 in vitro에서 유사한 결과를 보였다.

  • PDF

랫드의 대퇴 신경중 ATPase 효소활성에 미치는 납의 영향 (Effects of lead on ATPase activity in the sciatic nerve of Sprague-Dawley rat)

  • 정명규
    • Environmental Analysis Health and Toxicology
    • /
    • 제9권1_2호
    • /
    • pp.1-8
    • /
    • 1994
  • Nerve conduction impairment in lead neuropathy has been empirically linked to altered nerve myo-inositol metabolism. In most cases of neuropathy, abnormal myo-inositol metabolism is associated with abnormal $Na^+/K^+$ATPase provides a potential mechanism to relate defects of the myo-inositol metabolism in the peripheral nerve treated with lead. Therefore, the effect of lead on the rat sciatic nerve $Na^+/K^+$ATPase and other ATPase of sciatic nerve was studied. ATPase activity was measured enzymatically in sciatic nerve homogenates from 2-wk lead treated neuropathy rats and age-mached controls administered myo-inositol. $Na^+/K^+$ATPase components were assessed by ouabain inhibition or the omission of sodium and potassium ions. Lead reduced 50% reduction in the $Na^+/K^+$ATPase activity in homogenates of sciatic nerve. The 50% reduction in the $Na^+/K^+$ ATPase activity was selectively prevented by myo-inositol treatment. This study suggests that the toxic mechanism of the lead on peripheral nerve may be through reduction in $Na^+/K^+$ATPase activity which has been linked to axonal transport slowing in the rat model of lead neuropathy, via direct changes by the perturbation of the intracelluar sodium or potasium level.

  • PDF

Study on Determination of Seven Transition Metal Ions in Water and Food by Microcolumn High-Performance Liquid Chromatography

  • Hu, Qiufen;Yang, Guangyu;Li, Haitao;Tai, Xi;Yin, Jiayuan
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권5호
    • /
    • pp.694-698
    • /
    • 2004
  • A new method for the simultaneous determination of seven transition metal ions in water and food by microcolumn high-performance liquid chromatography has been developed. The lead, cadmium, mercury, nickel, cobalt, silver and tin ions were pre-column derivatized with tetra-(4-aminophenyl)-porphyrin ($T_4$-APP) to form the colored chelates which were then enriched by solid phase extraction with $C_{18}$ cartridge. The enrichment factor of 50 was achieved by eluted the retained chelates from the cartridge with tetrahydrofuran (THF). The chelates were separated on a ZORBAX Stable Bound microcolumn ($2.0{\times}50\;mm,\;1.8\;{\mu}m$)with methanol-tetrahydrofuran (95 : 5, v/v, containing 0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0) as mobile phase at a flow rate of 0.5 mL/min and detected with a photodiode array detector from 350-600 nm. The seven chelates were separated completely within 2.0 min. The detection limits of lead, cadmium, mercury, nickel, cobalt, silver and tin are 4 ng/L, 3 ng/L, 6 ng/L, 5 ng/L, 5 ng/L, 6 ng/L, 4 ng/L respectively in the original samples. This method was applied to the determination of the seven transition metal in water and food samples with good results.