• Title/Summary/Keyword: Layer image

Search Result 1,196, Processing Time 0.033 seconds

A Study on Development of Experimental Contents Using 3-channel Multi-Image Playback Technique: Based on transparent OLED and dual layer display system (3채널 멀티 영상 재생 기법과 증강현실을 이용한 체험 콘텐츠 제작에 관한 연구: 투명 OLED 및 듀얼 레이어 디스플레이 시스템 기반)

  • Lee, Sang-Hyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.151-160
    • /
    • 2017
  • Among the methods of developing tourist spots and culture as the experience contents, it is a common method to display high-quality video images on a large display, and it is necessary to make a special difference between the participant's active participation and the visual experience in other regions. In this paper, using the single molecular OLED and active type, the regional tourist spots blend transparent OLED dual-layer display systems with the extended image implementation and augmented interaction techniques to give the participants a real-world experience, such as directing to new experiences and beautiful sights. In this paper, additional images and UI layers are applied to the layers of the images to allow visitors to experience sightseeing information, weather, maps, accommodations, festivals and photo materials with image. In addition to the dual-layer system, it also added a multi-display system that additionally has one vertical 55-inch display on each side, adding to the experience the immersive experience and interface interlocking fun. By using transparent OLED, dual layer panel and 3-channel Multi-image playback technique, the augmented type experience contents which can experience the local attractions in Jeollanamdo province in Korea at all time without any limitation of time and space were developed.

Growth of GaAs/AlGaAs structure for photoelectric cathode (광전음극 소자용 GaAs/AlGaAs 구조의 LPE 성장)

  • Bae, Sung Geun;Jeon, Injun;Kim, Kyoung Hwa
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.6
    • /
    • pp.282-288
    • /
    • 2017
  • In this paper, GaAs/AlGaAs multi-layer structure was grown by liquid phase epitaxy with graphite sliding boat, which can be used as a device structure of a photocathode image sensor. The multi-layer structure was grown on an n-type GaAs substrate in the sequence as follows: GaAs buffer layer, Zn-doped p-type AlGaAs layer as etching stop layer, Zn-doped p-type GaAs layer, and Zn-doped p-type AlGaAs layer. The Characteristics of GaAs/AlGaAs structures were analyzed by using scanning electron microscope (SEM), secondary ion mass spectrometer (SIMS) and hall measurement. The SEM images shows that the p-AlGaAs/p-GaAs/p-AlGaAs multi-layer structure was grown with a mirror-like surface on a whole ($1.25mm{\times}25mm$) substrate. The Al composition in the AlGaAs layer was approximately 80 %. Also, it was confirmed that the free carrier concentration in the p-GaAs layer can be adjusted to the range of $8{\times}10^{18}/cm^2$ by hall measurement. In the result, it is expected that the p-AlGaAs/p-GaAs/p-AlGaAs multi-layer structure grown by the LPE can be used as a device structure of a photoelectric cathode image sensor.

Effects of Oxide Layer Formed on TiN Coated Silicon Wafer on the Friction and Wear Characteristics in Sliding (미끄럼운동 시 TiN 코팅에 형성되는 산화막이 마찰 및 마멸 특성에 미치는 영향)

  • 조정우;이영제
    • Tribology and Lubricants
    • /
    • v.18 no.4
    • /
    • pp.260-266
    • /
    • 2002
  • In this study, the effects of oxide layer farmed on the wear tracks of TiN coated silicon wafer on friction and wear characteristics were investigated. Silicon wafer was used for the substrate of coated disk specimens, which were prepared by depositing TiN coating with 1 ${\mu}{\textrm}{m}$ in coating thickness. AISI 52100 steel ball was used fur the counterpart. The tests were performed both in air for forming oxide layer on the wear track and in nitrogen to avoid oxidation. This paper reports characterization of the oxide layer effects on friction and wear characteristics using X-ray diffraction(XRD), Auger electron spectroscopy(AES), scanning electron microscopy (SEM) and multi-mode atomic force microscope(AFM).

Effects of oxide layer formed on TiN coated silicon wafer on the friction characteristics

  • Cho, C.W.;Lee, Y.Z.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.167-168
    • /
    • 2002
  • In this study, the effects of oxide layer formed on the wear tracks of TiN coated silicon wafer on friction characteristics were investigated. Silicon wafer was used for the substrate of coated disk specimens, which were prepared by depositing TiN coating with $1\;{\mu}m$ in coating thickness. AISI 52100 steel balls were used for the counterpart. The tests were performed both in air for forming oxide layer on the wear track and in nitrogen to avoid oxidation. This paper reports characterization of the oxide layer effects on friction characteristics using X-ray diffraction (XRD). scanning electron microscopy (SEM) and friction force microscope (FFM).

  • PDF

Second-Order Wave Resistance Calculation of Thin-Ship (얇은 배에 대한 고차 조파저항 계산)

  • Shin-Hyoung,Kang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.16 no.3
    • /
    • pp.35-47
    • /
    • 1979
  • Wave resistance of a parabolic thin ship, with its boundary layer and wake taken into account, was calculated up to second order. In addition to the double-model source distribution on the centerplane, image sources of the wave potential were calculated to keep the body introduced boundary condition undisturbed. Boundary layer and wake effects on the wave-making resistance were included by generating an irrotational flow which matches that exterior to the boundary layer and wake. For this purpose, the boundary layer and wake were calculated. The wave resistance refined with second-order corrections are found to be very important for wave resistance calculations even at moderate Froude numbers($Fr=0.2{\sim}0.3$). Wave-potential corrections are dominate around the bow. On the other hand, Viscosity plays and important role at the stern with its boundary layer and wake development.

  • PDF

A study of Satellite Image-Based Stereoscopic Vision System (위성영상 관련 입체도시시스템 개발에 관한 연구)

  • 김감래;김훈정;김주용
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.239-243
    • /
    • 2004
  • It does not exist almost that Most satellite image has both high spectral and spatial resolution. In order to apply the satellite image for to be actual, we need numerical and analytical technique development to improve the resolution. Specially in the function of solid illustration, we represent the solid image through the image generation to solid screen. The main function includes magnification, reduction, screen center movement, Panning, territory magnification. The method to process the image includes histogram and contrast modulation. Afterwards, we will develop the function includes 3-dimension cursor to control the elevation position and calculate the ground coordination automatically. There is the layer control includes the representation and the edition of 3D vector, extraction the Z value by On the Ground and digital elevation.

  • PDF

Study on the Improvement of Indirect Intra-Oral Dental Digital X-ray Image Sensor with Optical Coupling

  • Whang, Joo-Ho;Chung, Jin-Bum;Kim, Tae-Woo
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.514-525
    • /
    • 2001
  • Optimum characteristics of digital X-ray sensor components were analyzed to develop intra- oral dental digital X-ray image sensor using indirect method. Parametric analysis was carried out to optimize the phosphor thickness and the fiber optic plate (FOP) coupling to charge coupled device (CCD). X-ray absorption and light diffusion in the phosphor layer were analyzed by the Monte Carlo method. Real time X-ray image was obtained with prototype X- ray image sensor using general CCD camera with 1∼10 Ip/mm resolution. It has been previously shown that large resolution degradation in X-ray images was caused by miss alignment of FOP to CCD and optical adhesive selection. In this study, we reported that X-ray image quality was greatly improved by using optimized characteristics of alignment device and phosphor thickness.

  • PDF

Application of Image Processing Technique to Improve Production Efficiency of Fine Pitch Hole Based on Laser (레이저 미세피치 홀 가공의 생산효율성 향상을 위한 영상처리 측정 기법 적용)

  • Pyo, C.R.
    • Transactions of Materials Processing
    • /
    • v.19 no.5
    • /
    • pp.320-324
    • /
    • 2010
  • Multi-Layer Ceramic Circuit(MLCC) in the face of thousands of fine pitch multi hole is processed. However, the fine pitch multi hole has a size of only a few micrometers. Therefore, in order to curtail the measurement time and reduce error, the image processing measurement method is required. So, we proposed an image processing measurement algorithm which is required to accurately measure the fine pitch multi hole. The proposed algorithm gets image of the fine pitch multi hole, extracts object from the image by morphological process, and extracts the parameters of its position and feature by edge detecting process. In addition, we have used the sub-pixel algorithm to improve accuracy. As a result, the proposed algorithm shows 97% test-retest measurement reliability within 2 ${\mu}m$. We found that the algorithm was wellsuited for measuring the fine pitch multi hole.

AUTOMATIC 3D BUILDING INFORMATION EXTRACTION FROM A SINGLE QUICKBIRD IMAGE AND DIGITAL MAPS

  • Kim, Hye-Jin;Byun, Young-Gi;Choi, Jae-Wan;Han, You-Kyung;Kim, Yong-Il
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.238-242
    • /
    • 2007
  • Today's commercial high resolution satellite imagery such as that provided by IKONOS and QuickBird, offers the potential to extract useful spatial information for geographical database construction and GIS applications. Digital maps supply the most generally used GIS data probiding topography, road, and building information. Currently, the building information provided by digital maps is incompletely constructed for GIS applications due to planar position error and warped shape. We focus on extracting of the accurate building information including position, shape, and height to update the building information of the digital maps and GIS database. In this paper, we propose a new method of 3D building information extraction with a single high resolution satellite image and digital map. Co-registration between the QuickBird image and the 1:1,000 digital maps was carried out automatically using the RPC adjustment model and the building layer of the digital map was projected onto the image. The building roof boundaries were detected using the building layer from the digital map based on the satellite azimuth. The building shape could be modified using a snake algorithm. Then we measured the building height and traced the building bottom automatically using triangular vector structure (TVS) hypothesis. In order to evaluate the proposed method, we estimated accuracy of the extracted building information using LiDAR DSM.

  • PDF

Development of Radiation Image Sensor using Heterojunction (이종접합을 이용한 방사선 영상 센서 개발)

  • Kim, Young-Bin;Yun, Min-Seok;Kim, Min-Woo;Jung, Suk-Hee;Kim, Yoon-Suk;Oh, Kyung-Min;Nam, Sang-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.3
    • /
    • pp.27-35
    • /
    • 2009
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using double layer technique tio decrease dark current. High efficiency material in substitution for a-Se have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using Hetero junction already used as solar cell, semiconductor. Particle-In-Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in PIB method. To make up for the weak points, double layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity is measured to evaluate double layer radiation sensor material.

  • PDF