• Title/Summary/Keyword: Lateral structure

Search Result 1,337, Processing Time 0.028 seconds

An Experimental Study on Lateral Load Resistance of a Wall Structure Composed of Precast Concrete and H-Pile (H 파일과 프리캐스트 콘크리트로 형성된 벽체의 횡저항성능에 대한 실험적 연구)

  • Seo, Dong-Joo;Kang, Duk-Man;Lee, Hyun-Gee;Moon, Do-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.9-17
    • /
    • 2020
  • The purpose of this study was to evaluate lateral load resistance of a wall structure composed of precast concrete wall and H-Pile. This type of structure can be used for noise barrier foundation or retaining wall. Mock-up specimens having actual size were designed and fabricated. The lateral design load is 54.6kN. The H-pile length for the test specimen is 1.5m for simulating behavior of actual wall structure has 6.5m H-pile in the field, which is determined from theoretical study. Lateral displacements and strains of wall and H-pile were monitored and cracking in precast concrete wall inspected during the test. Load and deformation capacity of test specimens was compared with design capacity. The comparisons demonstrated that this type of structures, precast concrete wall and H-pile, can resist enough to lateral design load.

Seismic Analysis of Building Structures with Ambiguous Modal Direction (모드의 방향이 불분명한 건축구조물의 지진해석)

  • 김태호;이동근;김대곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.513-520
    • /
    • 2002
  • This study is for seismic analysis of building structures with ambiguous modal direction This case is revealed symmetrical building structure or the structure that isn't coincided building axis with physical axis. Seismic analysis-time history analysis, response spectrum analysis and lateral force procedure-is carried out. It is concluded that analysis method for the structure with ambiguous modal direction don't suitable for lateral force procedure. It is recommended to use the CQC method for combining modal responses to the individual components and the SRSS rule for combining responses to the two horizontal components are of nearly equal intensities.

  • PDF

Analysis of Reduction Effect on Noise Discharge from Lightweight Soundproof Tunnels Installed with Lateral Sound-absorbing Panels (직각 흡음체 설치 경량방음터널의 토출소음 저감효과 분석)

  • Jeong, Young Do;Ahn, Dong-Wook;Noh, Myung-Hyun
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2016
  • Most of the soundproof tunnels generate significant discharge noise through their inlets and outlets so that the length of the tunnel has been extended frequently than required to minimize the effect on such discharge noise. Thus, in this paper, we investigate reduction capability of discharge noise from the sound proof tunnel installed with lateral sound-absorbing panels on the partitioned truss members in the longitudinal direction of the tunnel. In conclusion, noise field analysis results shows that the sound proof tunnels with lateral sound-absorbing panels have an effect on discharge noise abatement and thereby tunnel's length reduction.

Crystal Structure of Tension Wood by X-ray Diffraction Method (X 선(線) 회절법(回折法)에 의한 Tension Wood의 결정구조(結晶構造) 해석)

  • Lee, Won-Yong;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.73-78
    • /
    • 1993
  • Crystal structure of tension, opposite and lateral wood of Platanus orientalis L. were analysed in some aspects of crystallinity index, crystallite size, d-spacing of (200) and (004), and integrated intensity ratios with X-ray diffraction method. Crystallinity index and crystallite width in tension wood appeared somewhat larger than opposite or lateral wood. However, d-spacing and integrated intensity ratios were nearly identical irrespective of tension, opposite, and lateral wood.

  • PDF

An Experimental Study on the Development of Unit Column Wall Form System Using (Focusing on the Lateral Pressure) (기둥식 벽체 거푸집 시스템 개발에 관한 실험적 연구)

  • Kang, Chang-Soo;Lee, Han-Seung;Tae, Sung-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.507-510
    • /
    • 2005
  • Euro form which constructs the present RC structures is used widely by the form method of construction of a wall type structure had much consumption of the human power and equipments by the assembly and the demolition, and the complement was required according to demerit with much leakage of cement paste by the form joint, so it developed the new pillar type form system. On the study, in order to consider the modification characteristic by lateral pressure which does the influence most important for the new developed pillar type form system performance, research of a paper manufactured a miniature wall form model, and advanced performance evaluation focusing on lateral pressure. Moreover, lateral pressure evaluation of a new style system was actually gone on through the on-site experiment about a part of wall type srutcture spot for a model experiment and its result on the foundation which is the purpose in evaluating on-site application possibility propriety at the foundation time of wall type concrete structure construction of a pillar type form system.

  • PDF

Numerical Study of Double Diffusive Convection of a Stratified Fluid in an Annulus Due to Lateral Heating (환형밀폐용기내 성층화된 유체의 옆면가열에 의한 이중확산대류에 관한 수치해석)

  • 강신형;전창덕;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1720-1730
    • /
    • 1995
  • Finite-difference analysis was conducted to study the natural convection of a stably stratified salt-water solution in an annulus due to lateral heating. The main purpose of this study is to examine in detail the multi-layered flow structure. Calculation was thus made for R $a_{\eta}$=2*10$^{5}$ and 6.5*10$^{5}$ . Formation of layered flow structure, merging process of layers, the corresponding temperature and concentration distributions, Nusselt number variations with time are examined. Numerical results show that in each layer, the temperature profile looks 'S`-shaped and the concentration profile is uniform due to the convective mixing. The formation of the roll and the layer is governed by natural convection due to the temperature gradient and the merging process of the layer by diffusion of the concentration.ation.

Estimation of Appropriate Reinforcement Length of Casing for the Pile of Pile Bent System through Numerical Analysis (수치해석을 통한 단일형 현장타설말뚝 외부강관의 적정 보강길이 산정)

  • Yang, Wooyeol;Kim, Wanho;Lee, Kangil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.6
    • /
    • pp.5-15
    • /
    • 2021
  • One of the construction methods applied as a pier foundation type is a single type cast-in-place pile. In applying a pile bent system as a foundation type, the main concern in designing can be said to secure the lateral bearing capacity of pile structure in system. In addition, to increase the rigidity of the pile structure, a method of increasing the lateral bearing capacity by reinforcing the pile structure with a casing has been used. However, although the reinforcing effect and appropriate reinforcing length of casing may vary depending on the soil conditions, there is insufficient studies on this, and for this reason, the entire pile structure in a pile bent system is reinforced with a casing, in the field. In addition, if the length of the entire pile is reinforced with a casing, it may lead to delays in construction and increase in construction costs. That is, in order to more effectively reinforce the pile structure with a casing, it is necessary to study the lateral bearing characteristics of the reinforced pile structure in system. And it should be determined the appropriate reinforcing length of the casing from the evaluated bearing characteristics. Therefore, in this study, the lateral bearing characteristics of piles applied with the reinforcing length of casing for each condition were evaluated through a numerical analysis. And, based on the analysis results, the appropriate reinforcing length of casing was proposed. As a result of the study, it was found that in order to effectively increase the lateral bearing capacity of pile structure, the reinforcing length of casing should be applied twice the influence range of the bending behavior of the pile, 1/β.

An analysis of the lateral first-order mode characteristics for the semiconductor laser diodes (반도체 레이저 다이오드의 횡방향 1차모드의 특성 해석)

  • 김형래;곽계달
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.12
    • /
    • pp.91-100
    • /
    • 1995
  • This paper represents the lateral first-order mode characteristics for the semiconductor laser diodes using a two-dimensional numerical simulator. In order to analyze the lateral first-order mode characteristics, Helmholtz wave equation is solved twice for the lateral fundamental and the first-order mode considering the mode gain, total losses, and the recombination rate due to the stimulated emission radiation for the each mode independantly. Through this procedure, we find that the lateral first-order mode was easily guided as increasing the stripe width for the index-guiding structures, and that the lateral first-order mode seems to be dominated in the distribution of total light intensity when its output power reaches nearly half of that of the lateral fundamental mode. This results may be used to design the device structure which guides only the lateral fundamental mode.

  • PDF

Experimental study on seismic behavior of two-storey modular structure

  • Liu, Yang;Chen, Zhihua;Liu, Jiadi;Zhong, Xu
    • Steel and Composite Structures
    • /
    • v.37 no.3
    • /
    • pp.273-289
    • /
    • 2020
  • Due to the unique construction method of modular steel buildings (MSBs) with units prefabricated fully off the site and assembled quickly on the site, the inter-module connection for easy operation and overall performance of the system were key issues. However, it was a lack of relevant research on the system-level performance of MSBs. This study investigated the seismic performance of two-storey modular steel structure with a proposed vertical rotary inter-module connection. Three full-scale quasi-static tests, with and without corrugated steel plate and its combination, were carried out to evaluate and compare their seismic behaviour. The hysteretic performance, skeleton curves, ductile performance, stiffness degradation, energy dissipation capacity, and deformation pattern were clarified. The results showed that good ductility and plastic deformation ability of such modular steel structures. Two lateral-force resistance mechanisms with different layout combinations were also discussed in detail. The corrugated steel plate could significantly improve the lateral stiffness and bearing capacity of the modular steel structure. The cooperative working mechanism of modules and inter-module connections was further analyzed. When the lateral stiffness of upper and lower modular structures was close, limited bending moment transfer may be considered for the inter-module connection. While a large lateral stiffness difference existed initially between the upper and lower structures, an obvious gap occurred at the inter-module connection, and this gap may significantly influence the bending moments transferred by the inter-module connections. Meanwhile, several design recommendations of inter-module connections were also given for the application of MSBs.

Lateral Force Resisting System of Flat Plate Structure based on KBC 2008 Draft (KBC2008(안)에 근거한 무량판구조의 횡력저항시스템)

  • Kim, Do-Hyun;Lee, Hyun-Ho;Kim, Young-Sik;Woo, Sung-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.871-874
    • /
    • 2008
  • In the beginning of KBC-2005, many structural engineers had have difficulty in designing the flat plate structures. Recently KBC-2005 has been revising. At this point, we need to study the lateral resisting systems which are based on KBC-2008 draft and applicable to the flat plate structure. When the RC structure system of KBC 2008 draft is compared with that of KBC-2005, there are some differences. (1) Structural system and height limitations according to seismic design category (2) Special Requirement such as special RC shear wall (3) New lateral force resisting system such as shear wall-frame interaction system The KBC-2008 will give structural engineers to choose the various lateral force resisting system

  • PDF