• Title/Summary/Keyword: Lateral resistance force

Search Result 122, Processing Time 0.024 seconds

A Study on the Rectangular-Shaped Passive Row Piles in Inclined Sand-Ground by Model Test (경사모래지반의 사각형 수동 열말뚝에 관한 실험적 연구)

  • Bae, Jong-Soon;Kim, Ji-Seong;Kwon, Min-Jae
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.39-51
    • /
    • 2009
  • This is a study on rectangular-shaped passive row piles in inclined sand-ground by model tests. The experiment controlled the angle of inclination of ground and induced the ground destruction. We also measured the behavior of row piles, by adjusting the shape, position and spacing of piles. As a result, we confirmed the earth pressure, the lateral resistance, and the effect of depressing on the ground variation working on passive pile. The effect of B-type pile of which the front width is wide is bigger than that of H-type pile of which the side width is wide. We can find out the failure angle of slope, the shared force of pile and soil by using the lateral resistance graph based on slope angle.

Out-of-plane performance of infill masonry walls reinforced with post-compressed wedges under lateral-concentrated push load

  • Sanghee Kim;Ju-Hyun Mun;Jun-Ryeol Park;Keun-Hyeok Yang;Jae-Il Sim
    • Earthquakes and Structures
    • /
    • v.26 no.6
    • /
    • pp.489-499
    • /
    • 2024
  • Infill masonry walls are vulnerable to lateral loads, including seismic, wind, and concentrated push loads. Various strengthening metal fittings have been proposed to improve lateral load resistance, particularly against seismic loads. This study introduces the use of post-compressed wedges as a novel reinforcement method for infill masonry walls to enhance lateral load resistance. The resistance of the infill masonry wall against lateral-concentrated push loads was assessed using an out-of-plane push-over test on specimens sized 2,300×2,410×190 mm3. The presence or absence of wedges and wedge spacing were set as variables. The push-over test results showed that both the unreinforced specimen and the specimen reinforced with 300 mm spaced wedges toppled, while the specimen reinforced with 100 mm spaced wedges remained upright. Peak loads were measured to be 0.74, 29.77, and 5.88 kN for unreinforced specimens and specimens reinforced with 100 mm and 300 mm spaced wedges, respectively. Notably, a tighter reinforcement spacing yielded a similar strength, as expected, which was attributed to the increased friction force between the masonry wall and steel frame. The W-series specimens exhibited a trend comparable to that of the displacement ductility ratio. Overall, the findings validate that post-compressed wedges improve the out-of-plane strength of infill masonry walls.

Equivalent lateral force method for buildings with setback: adequacy in elastic range

  • Roy, Rana;Mahato, Somen
    • Earthquakes and Structures
    • /
    • v.4 no.6
    • /
    • pp.685-710
    • /
    • 2013
  • Static torsional provisions employing equivalent lateral force method (ELF) require that the earthquake-induced lateral force at each story be applied at a distance equal to design eccentricity ($e_d$) from a reference resistance centre of the corresponding story. Such code torsional provisions, albeit not explicitly stated, are generally believed to be applicable to the regularly asymmetric buildings. Examined herein is the applicability of such code-torsional provisions to buildings with set-back using rigid as well as flexible diaphragm model. Response of a number of set-back systems computed through ELF with static torsional provisions is compared to that by response spectrum based procedure. Influence of infill wall with a range of opening is also investigated. Results of comprehensive parametric studies suggest that the ELF may, with rational engineering judgment, be used for practical purposes taking some care of the surroundings of the setback for stiff systems in particular.

Elastic Resistance Exercise for the Elderly on the Magnitude of Frequency and Variability of Ground Reaction Force Signals during Walking (고령자 보행 시 탄성저항운동이 지면반력 신호의 주파수 크기와 variability에 미치는 영향)

  • Seo, Se-Mi;Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.49-57
    • /
    • 2008
  • The purpose of this study was to determine the effects of 12-week elastic resistance exercise for the elderly on the magnitude of frequency and variability of ground reaction force signals. To this aim, total 12 elderly women aged in their 70 were participated in this study and asked to do a 12-week elastic resistance exercise program. FFT(fast Fourier Transform) was used to analyze the frequency domain analysis of the ground reaction forces's signals and an accumulative PSD (power spectrum density) normalized by support phase of walking was calculated to reconstruct the certain signals. To estimate the gait stability between the before and after exercise, values of variability were determined in a coefficient of variance. The magnitude of frequency and variability analysis for media-lateral signal revealed significantly less after exercise (p<.05). In contrast, variability of this signal's frequency that have used to evaluate the local stability during walking exhibited significantly greater after exercise(p<.05). In summary, magnitude frequency and variability of media-lateral ground reaction force's signal were significantly changed after a 12-week elastic resistance exercise.

Relationships for prediction of backstay effect in tall buildings with core-wall system

  • Karimi, Mahdi;Kheyroddin, Ali;Shariatmadar, Hashem
    • Advances in Computational Design
    • /
    • v.5 no.1
    • /
    • pp.35-54
    • /
    • 2020
  • One of the prevailing structural systems in high-rise buildings is the core-wall system. On the other hand, the existence of one or more underground stories causes the perimeter below-grade walls with the diaphragm of grade level to constitute of a very stiff box. In this case or a similar situation, during the lateral response of a tall building, underground perimeter walls and diaphragms that provide an increased lateral resistance relative to the core wall may introduce a prying action in the core that is called backstay effect. In this case, a rather great force is generated at the diaphragm of the grade-level, acting in a reverse direction to the lateral force on the core-wall system, and thus typically causes a reverse internal shear. In this research, in addition to review of the results of the preceding studies, an improved relationship is proposed for prediction of backstay force. The new proposed relationship takes into account the effect of foundation flexibility and is presented in a non-dimensional form. Furthermore, a specific range of the backstay force to lateral load ratio has been determined. And finally, it is shown that although all suggested formulas are valid in the elastic domain, yet with some changes in the initial considerations, they can be applied to some certain non-linear problems as well.

The Effect of Higher Vibration Modes on the Design Seismic Load (고차진동모드의 영향을 고려한 층지진하중)

  • 이동근;신용우
    • Computational Structural Engineering
    • /
    • v.3 no.4
    • /
    • pp.123-132
    • /
    • 1990
  • In current practice of earthquake resistant design the equivalent lateral force procedure is widely used because of its simplicity and convenience. But the equivalent lateral force procedure is derived based on the assumptions that the dynamic behavior of the structure is governed primarily by the fundamental vibration mode and the effect of higher modes is included in an approximate manner. Therefore the prediction of dynamic responses of structures using the equivalent lateral force procedure is not reliable when the effect of higher vibration modes on the dynamic behavior is significant. In this study, design seismic load which can reflect the effect of higher vibration modes is proposed from the point of view of proper assessment of story shears which have the major influence on the design moment of beams and columns. To evaluate the effect of higher modes, differences between the story force based on the equivalent lateral force procedure specified in current earthquake resistance building code and the one based on modal analysis using design spectrum analysis are examined. From these results an improved design seismic load for the equivalent lateral force procedure which can reflect the effect of higher vibration modes are proposed.

  • PDF

The Study on Field Performance Test of Multi Branch Type Tie(GOLRY TIE) (다지형 침목 현장 성능평가에 관한 연구)

  • Kim, Hae-Gon;Suh, Dong-Seok;Kim, Nam-Hong;Lee, Syeung-Youl
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.162-166
    • /
    • 2011
  • In railway, Tie supports rail and plays a role that distribute train load to the ballast. Also, Tie and ballast resist against external force and fix the track position. But, weakening resistance of ballast and tie cause vertical displacement of tie and track irregularity. For reinforcement of track stiffness and reduction of track irregularity, KORAIL has developed Multi Branch type tie(GLORY Tie) that reinforced resistance than general PCT and installed in order to test in the field. This study measured and analyzed lateral resistance of ballast, wheel load of rail, bending strain of rail foot, vertical displacement and vibration acceleration of tie in order to evaluate performance of Multi Branch type tie in the field. According to the results of test, Multi Branch tie is excellent than general tie about lateral resistance of ballast and vertical displacement of tie. And, gap of measurement value between Multi Branch type tie and general tie about wheel load of rail, bending strain of rail foot were very small.

  • PDF

Vertical distributions of lateral forces on base isolated structures considering higher mode effects

  • Tsai, C.S.;Chen, Wen-Shin;Chen, Bo-Jen;Pong, Wen-Shen
    • Structural Engineering and Mechanics
    • /
    • v.23 no.5
    • /
    • pp.543-562
    • /
    • 2006
  • Base isolation technology has been accepted as a feasible and attractive way in improving seismic resistance of structures. The seismic design of new seismically isolated structures is mainly governed by the Uniform Building Code (UBC-97) published by the International Conference of Building Officials. In the UBC code, the distribution formula of the inertial (or lateral) forces leads to an inverted triangular shape in the vertical direction. It has been found to be too conservative for most isolated structures through experimental, computational and real earthquake examinations. In this paper, four simple and reasonable design formulae, based on the first mode of the base-isolated structures, for the lateral force distribution on isolated structures have been validated by a multiple-bay three-story base-isolated steel structure tested on the shaking table. Moreover, to obtain more accurate results for base-isolated structures in which higher mode contributions are more likely expected during earthquakes, another four inertial force distribution formulae are also proposed to include higher mode effects. Besides the experimental verification through shaking table tests, the vertical distributions of peak accelerations computed by the proposed design formulae are in good agreement with the recorded floor accelerations of the USC University Hospital during the Northridge earthquake.

A study on determining the minimum vertical spring stiffness of track pad considering running safety. (열차주행안전을 고려한 궤도패드의 최소 수직 스프링계수 결정에 관한 연구)

  • Kim Jeong-ll;Yang SinChu;Kim Yun-Tae
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.842-847
    • /
    • 2004
  • This study presents the minimum spring stiffness of resilient track pad considering the safety of running train. A nonlinear static 3-D finite element is used for the modeling of railway superstructure, especially for the reflection of nonlinear resistance of rail fastening system. Moreover, ballast is considered as an elastic foundation. As the input load, eccentric wheel and lateral force are used and they are derived from ' Lateral-force/Wheel-load Estimation Equations '. Analysis results are compared with following two values : allowable lateral displacement of rail head (derived from the geometrical derailment evaluation of wheel/rail) and operation standard value (derived from the field test results of track).

  • PDF

Structural Behavior of Post-Tensioned Flat Plate Slab-Column Connections (포스트 텐션 플랫 플레이트 슬래브 접합부의 거동)

  • Cho Kyung Hyun;Han Sang Whan;Lee Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.53-56
    • /
    • 2004
  • Recently, post tension flat plate slab system is widely used for a new slab structural system. Slab-column connections may fail in brittle manner by punching shear. Flat plate slabs have been widely used for gravity load resisting system in buildings. Lateral resistance usually provided by shear walls or moment resisting frames. Since plat plates move together with lateral loading system during earthquake or wind, it is important to evaluate the gravity resistance under a drift experienced by lateral force resisting system during either design earthquake or wind. Thus, this study investigated post tension flat plate slab systems whether they have sufficient strength and deformability to resist gravity loads during specified drift levels. Experimental research was carried out.

  • PDF