• 제목/요약/키워드: Lateral Heating

검색결과 41건 처리시간 0.034초

전열침(傳熱鍼)과 일반 침의 병행치료가 발목 염좌로 인한 외측인대 2도 손상에 미치는 임상적 효과 (The Clinical Effects of Heating-conduction Acupuncture Therapy with General Acupuncture Therapy for Lateral Ligament Injury Induced by Ankle Sprain Grade II)

  • 장선정;장효길;허동석
    • 한방재활의학과학회지
    • /
    • 제21권4호
    • /
    • pp.191-203
    • /
    • 2011
  • Objectives: The purpose of this study is to investigate the clinical effects of heating-conduction therapy on lateral ligament injury induced by ankle sprain grade II. Methods: The 67 outpatients who were diagnosed as ankle sprain grade II were performed heating-conduction acupuncture therapy on lateral ligament injury. To evaluate the efficiency of heating-conduction acupuncture therapy, pain threshold with pressure algometer and visual analogue scale(VAS) were applied pretreatment and after 1st, 2nd treatment. Results: 1. The pain threshold and VAS score after 1st and 2nd treatment with an isolated injury of the anterior talofibular ligament showed statistically significant improvement compared with pretreatment. 2. The VAS score after 1st and 2nd treatment with an combined injury to the anterior talofibular and the calcaneofibular ligament showed statistically significant improvement compared with pretreatment. 3. The VAS score after 1st and 2nd treatment with an combined injury to the anterior talofibular, calcaneofibular and posterior talofibular ligament showed statistically significant improvement compared with pretreatment. 4. After 1st and 2nd treatment on the posterior talofibular ligament and after 2nd treatment on the anterior taofibular and calcaneofibular ligament with an combined injury to the anterior talofibular, calcaneofibular and posterior talofibular ligament the pain threshold showed statistically significant improvement compared with pretreatment. 5. Between isolated injury and combined injury of lateral ligament, the difference in pain threshold and VAS score was not statistically significant. Conclusions: Heating-conduction acupuncture therapy has clinical effects of pain reduction on patient with an isolated injury and combined injury of lateral ligament induced by ankle sprain grade II.

환형밀폐용기내 성층화된 유체의 옆면가열에 의한 이중확산대류에 관한 수치해석 (Numerical Study of Double Diffusive Convection of a Stratified Fluid in an Annulus Due to Lateral Heating)

  • 강신형;전창덕;이진호
    • 대한기계학회논문집
    • /
    • 제19권7호
    • /
    • pp.1720-1730
    • /
    • 1995
  • Finite-difference analysis was conducted to study the natural convection of a stably stratified salt-water solution in an annulus due to lateral heating. The main purpose of this study is to examine in detail the multi-layered flow structure. Calculation was thus made for R $a_{\eta}$=2*10$^{5}$ and 6.5*10$^{5}$ . Formation of layered flow structure, merging process of layers, the corresponding temperature and concentration distributions, Nusselt number variations with time are examined. Numerical results show that in each layer, the temperature profile looks 'S`-shaped and the concentration profile is uniform due to the convective mixing. The formation of the roll and the layer is governed by natural convection due to the temperature gradient and the merging process of the layer by diffusion of the concentration.ation.

환형용기내 성층화된 유체의 회전효과에 따른 이중확산대류에 관한 실험적 연구 (Double Diffusive Convection of a Stratified Fluid in a Rotating Annulus Due to Lateral Heating)

  • 강신형;전창덕;이진호
    • 대한기계학회논문집
    • /
    • 제19권7호
    • /
    • pp.1709-1719
    • /
    • 1995
  • The primary objective of the paper is to obtain the basic information of the natural convection of a stratified with various parametric conditions related to rotating speed, temperature and concentration gradient. For the purpose of it, experiments are performed in a stably stratified salt-water solution with lateral heating in a stationary or rotating annulus. The experiment covers the ranges of Ar=2, Le=100, R $a_{\ta}$=2 10$^{5}$ and Ta=0, 10$^{5}$ - 2.5*10$^{8}$ . Many interesting flow phenomena are observed and rotation effects are examined. Particularly as Taylor number increases (rotation increases) at a given R $a_{\ta}$, the generation of rolls at hot wall is inhibited and the formation and merging process of layers are delayed.

지중가온이 백침계 오이의 측지 발생에 미치는 영향 (Effect of Soil Heating and Lateral Branching in White Spined Cucumbers)

  • Sang Gyu Lee;Ki Cheol Seong;Kwan Dal Ko;Kwang yong Kim
    • 생물환경조절학회지
    • /
    • 제10권3호
    • /
    • pp.155-158
    • /
    • 2001
  • 최근 수출을 위한 백침계오이의 재배 면적이 계속적인 증가 추세에 있어 2000년 현재 약 121ha에 달하고 있다. 백침계오이는 측지 착과형으로 흑침계오이와 달라 수량이 측지의 발생여부에 달려 있다. 그런데 백침오이의 주재배시기는 10월에서 2월까지의 겨울철로, 온도가 낮고, 투광량 부족하여 측지발생율이 저조하다. 따라서 본 시험은 백침계오이의 측지 발생율을 높이기 위한 지중가온의 효과를 구명하고자 실시하였다. 그 결과, 지중가온구는 주당 측지발생수가 13.7%개였고, 무가온구는 11.7개로 지중가온을 하면 측지발생수가 증가함을 알수 있었다. 또한 상품수확과수에 있어서도 지중가온구는 주당 45개인데 반해 지중무가온구는 38개였고, 전체적인 수량도 ha당 81톤으로, 무가온구의 68톤 보다 18%의 증수효과가 있어다. 즉, 수출오이재배시 지중가온을 하면, 측지발생수가 증가하고 특히 장측지가 다수 발생하여 측지 수확과수가 증가하며, 곡과의 발생이 감소하여 상품수량을 증가시킬 수 있다.

  • PDF

Crystallization Mechanisms of Joule-Heating-Induced Crystallization

  • Park, Doo-Jung;Ro, Jae-Sang
    • Journal of Information Display
    • /
    • 제10권2호
    • /
    • pp.76-79
    • /
    • 2009
  • In Joule-heating-induced crystallization, solid-to-solid or liquid-to-solid phase transformation could occur. It was found that novel physical phenomena that randomly nucleated liquid seeds, followed by rapid solidification in an amorphous matrix, during the Joule-heating-up period play an important role especially in liquid-to-solid transformation. Under some processing conditions, super-grains sized 6-8 ${\um}m$ were produced by the lateral growth from the initial seeds, without any artificially control.

회전하는 환형용기내의 옆면 가열에 의한 이중확산대류에 관한 수치해석 (Numerical study of double diffusive convection due to lateral heating in a rotating annulus)

  • 강신형;이교승;이진호
    • 대한기계학회논문집B
    • /
    • 제21권11호
    • /
    • pp.1422-1436
    • /
    • 1997
  • Numerical investigations were conducted to study the convective phenomena of an initially stably stratified salt water solution with lateral heating in a uniformly rotating annulus. The method of investigation is the finite difference analysis of the basic conservation equation for an axisymmetric, unsteady, double-diffusive convection and calculation is made for R $a_{\eta}$=2*10$^{5}$ and Ta=10$^{7}$ ~ 2.5*10$^{8}$ . Formation of layered flow structure, merging process of layers, the corresponding temperature and concentration distributions, Nu variation with time are examined. Numerical results show that in each layer, the temperature profile looks 'S'-shaped and the concentration profile is uniform due to the convective mixing. At the interface between adjacent layers, the temperature changes smoothly but the concentration changes rapidly. As the effect of the rotation increases, the generation of rolls at hot wall, the formation and merging of layers are delayed. The average Nu shows the trend of conduction heat transferees the effect of the rotation increases.n increases.

고성능 RC 기둥의 재하가열시험에 의한 내화 특성 (Properties of Fire Endurance of High Performance RC Column by Loaded Heating Test)

  • 김경민;김기훈;황인성;이재삼;이성연;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.57-60
    • /
    • 2005
  • This study discusses spalling and fire enduring performance of high performance concrete (HPC) RC column subjected to loading under heating for 3 hours. According to the test, both the plain concrete and the concrete attached with fire enduring PC panel exceed allowable temperature after 60 minutes due to the exposure of steel bar and falling off of concrete resulting from severe spalling failure. It leads to buckling of main bar and at the same time, occurrence of collapse of plain HPC column member is observed after 2 hours and 1 hour 40 minutes's exposure to fire, respectively. On the other hand, HPC applying both PP fiber of 0.1$\%$ by mass of concrete and PP fiber+lateral confinement by metal lath maintains their original cross section, which is satisfied with the 3 hours fire endurance criteria, by discharging internal vapour pressure and enhanced lateral confinement force.

  • PDF

Prediction of residual mechanical behavior of heat-exposed LWAC short column: a NLFE model

  • Obaidat, Yasmeen T.;Haddad, Rami H.
    • Structural Engineering and Mechanics
    • /
    • 제57권2호
    • /
    • pp.265-280
    • /
    • 2016
  • A NLFE model was proposed to investigate the mechanical behavior of short columns, cast using plain or fibrous lightweight aggregate concrete (LWAC), and subjected to elevated temperatures of up to $700^{\circ}C$. The model was validated, before its predictions were extended to study the effect of other variables, not studied experimentally. The three-dimensional NLFE model was developed using ANSYS software and involved rational simulation of thermal mechanical behavior of plain and fibrous LWAC as well as longitudinal and lateral steel reinforcement. The prediction from the NLFE model of columns' mechanical behavior, as represented by the stress-strain diagram and its characteristics, compared well with the experimental results. The predictions of the proposed models, considering wide range of lateral reinforcement ratios, confirmed the behaviors observed experimentally and stipulated the importance of steel confinement in preserving post-heating mechanical properties of plain and fibrous LWAC columns, being subjected to high temperature.

Design and Performance Evaluation of Extension-Type Actuators with a Displacement Amplification Mechanism Based on Chevron Beam

  • Jo, Yehrin;Lee, Euntaek;Kim, Yongdae
    • 항공우주시스템공학회지
    • /
    • 제15권6호
    • /
    • pp.1-9
    • /
    • 2021
  • In this study, a new design of an extension-type actuator (ExACT) is proposed based on a chevron structure with displacement amplification mechanisms by local heating. ExACT comprises diamond-shaped displacement amplification structures (DASs) containing axially oriented V-shaped chevron beams, a support bar that restricts lateral heat deformation, and a loading slot for thin-film heaters. On heating the thin film heater, the diamond-shaped DASs undergo thermal expansion. However, lateral expansion is restricted by the support bar, leading to displacement amplification in the axial direction. The performance parameters of ExACT such as temperature distribution and extended displacement is calculated using thermo-mechanical analysis methods with the finite element method (FEM) tool. Subsequently, the ExACTs are fabricated using a polymer-based 3D printer capable of reproducing complex structures, and the performance of ExACTs is evaluated under various temperature conditions. Finally, the performance evaluation results were compared with those of the FEM analysis.

난방시 가압식 바닥취출 공조방식의 실내온열환경 평가 (An Estimation on Indoor Thermal Environment by Pressurized Plenum Under Floor Air Conditioning System in Heating)

  • 최은훈;이용호;권영철;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.92-99
    • /
    • 2010
  • The purpose of this study is to apply pressurized plenum under floor air conditioning system to office areas to understand characteristics of indoor thermal environment based on forms of diffusers. For doing this, the author conducted experiment of module measurement, and based on the results, analyzed indoor temperature distribution and velocity distribution based on direction of diffusion by using Computational Fluid Dynamics(CFD), and estimated the Predicted Mean Vote(PMV) of residents based on forms of diffusers to present the optimal air conditioning of the pressurized plenum under floor air conditioning system in heating. The results of this study are as follows. First, as for forms of diffusers, distributed diffusers rather than conical and grill diffusers were favorable in maintaining $24^{\circ}C$, the established temperature in heating, were active in velocity flowing, and were wide in a radius of diffusion. Second, as for position of pressurizing, the difference between upper and lower temperature was wider in center, lateral, and dispersed pressurizing (in order). As for velocity distribution, the velocity was more increased in lateral, center, and dispersed pressurizing(in order), indicating that dispersed pressurizing maintained uniform thermal environment. Third, as for diffusion direction, mixed direction showed less difference between upper and lower temperature and the difference in velocity between center and lateral part was 0.01m/1, indicating that it maintained uniform thermal environment. Fourth, as for the PMV of residents based on the forms of diffusers, the dispersed type showed(+) values above (0) when applied variably based on the position of diffuser, presenting thermal feeling of "being comfortable" to residents.