• 제목/요약/키워드: Laser-induced plasma

검색결과 142건 처리시간 0.034초

헬리콘 플라즈마를 이용한 $Ge_2Sb_2Te_5(GST)$ 상변화 재료의 식각 특성 검토 (Etching Characteristics of $Ge_2Sb_2Te_5$ Using High-Density Helicon Plasma for the Nonvolatile Phase Change Memory Applications)

  • 윤성민;이남열;류상욱;신웅철;유병곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.203-206
    • /
    • 2004
  • For the realization of PRAM, $Ge_2Sb_2Te_5$ (GST) has been employed for the phase transition between the crystal and amorphous states by electrical joule heating. Although there has been a vast amount of results concerning the GST in material aspect for the laser-induced optical storage disc applications, the process-related issues of GST for the PRAM applications have not been reported. In this work, the etching behaviors of GST were investigated when the processing conditions were varied in the high-density helicon plasma. The etching parameters of RF main power, RF bias power, and chamber pressure were fixed at 600 W, 150 W, and 5 mTorr, respectively. For the etching processes, gas mixtures of $Ar/Cl_2$, $Ar/CF_4$, and $Ar/CHF_3$ were employed, in which the etching rates and etching selectivities of GST thin film in given gas mixtures were evaluated. From obtained results, it is found that we can arbitrarily design the etching process according to given cell structures and material combinations for PRAM cell fabrications.

  • PDF

레이저 유기 형광법을 이용한 자기장이 인가된 유도결합플라즈마의 전기장 특성 연구

  • 송재현;김혁;정재철;황기웅
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.474-474
    • /
    • 2010
  • 현재 반도체시장의 확장으로 인해서 기존의 300mm 웨이퍼에서 450mm의 웨이퍼를 사용하는 공정으로 변화하는 추세이다. 450mm 웨이퍼로 대면적 화되면서 기존 300mm 공정 때보다 훨씬 효율적인 플라즈마 소스 즉, 고밀도이고, 고균등화(high uniformity) 플라즈마 소스를 필요로 한다. 본 논문에서는 고밀도 플라즈마 소스인 유도 결합형 플라즈마(Inductively Coupled Plasma ; ICP)에 축 방향의 약한 자기장을 인가시킨 자화된 유도결합형 플라즈마(Magnetized Inductively Coupled Plasma : MICP)[1]를 제안하여 기존 ICP와의 차이점을 살펴보았다. 실험 방법으로 레이저 유기 형광법(Laser Induced Fluorescence : LIF)[2]을 이용하여 플라즈마 쉬스(Sheath) 내의 전기장을 외부 자기장의 변화에 따라 높이별로 측정하고 그 결과로부터 쉬스의 전기적 특성을 살펴보았다. 플라즈마의 특성상 탐침이나 전극에 전압을 인가하면 그 주위로 디바이 차폐(Debye Shielding)현상이 일어나서 플라즈마 왜곡이 일어난다. 그렇기에 플라즈마, 특히 플라즈마 쉬스의 특성을 파악하기 위해서 레이저라는 기술을 사용하였다. 레이저는 고가의 장비이고 그 사용에 많은 경험지식(know-how)를 필요로 하지만 플라즈마를 왜곡시키지 않고, 플라즈마의 밀도, 온도, 전기장 등 많은 상수(parameter)들을 얻어 낼 수 있다. 또한 3차원적으로 높은 분해능을 가지고 있는 장점이 있다. 강한 전기장이 있는 곳에서 입자들의 고에너지 준위가 전기장의 세기에 비례하여 분리되는 Stark effect[3] 이론을 이용하여 플라즈마 쉬스내의 전기장을 측정하였다. 실험은 헬륨가스 700mTorr 압력에서 이루어졌다. 기판의 파워를 50W에서 300W까지 변화시키면서 기판에 생기는 쉬스의 전기장의 변화를 살펴보았고, 자기장을 인가한 후 동일한 실험을 하여 자기장의 유무에 따른 플라즈마 쉬스의 전기장 변화를 살펴보았다. 실험결과 플라즈마 쉬스의 전기장의 변화는 기판의 파워와 플라즈마 밀도에 크게 의존함을 알았다. 기판의 파워가 커질수록 쉬스의 전기장은 커지고, 기판에 생기는 Self Bias Voltage역시 음의 방향으로 커짐을 확인 하였다. 또한 자기장을 걸어주었을 경우 쉬스의 두께가 얇아짐으로써 플라즈마의 밀도가 증가했음을 확인 할 수 있었다.

  • PDF

가스터빈 날개용 경사기능재료의 열충격 특성 (Thermal shock characteristics of FGM for gas turbine blade)

  • 임재규;송준희;김연직
    • 대한기계학회논문집A
    • /
    • 제22권1호
    • /
    • pp.73-79
    • /
    • 1998
  • The development of a new material which should be continuously usable under severe environment of very high temperature has been urgently requested. The conventional thermal barrier coating(TBC) is a two layer coating, but a composition and a microstructure of functionally graded material(FGM) are varied continuously from place to place in ways designed to provide it with the maximum function of mitigating the induced thermal stress. The purpose of this study is to evaluate the heat-resistant characteristics by thermal shock of laser and furnace heating. The fracture behaviors of non-FGM(NFGM) and FGM were investigated based on acoustic emission(AE) technique during thermal shock test. Therefore, it can be concluded that FGM gives higher thermal resistance compared to NFGM by AE signal and fracture surface analysis.

Membrane Perturbation Induced by Papiliocin Peptide, Derived from Papilio xuthus, in Candida albicans

  • Lee, June-Young;Hwang, Jae-Sam;Hwang, Bo-Mi;Kim, Jin-Kyoung;Kim, Seong-Ryul;Kim, Yang-Mee;Lee, Dong-Gun
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권8호
    • /
    • pp.1185-1188
    • /
    • 2010
  • Previously, papiliocin was isolated from the swallowtail butterfly Papilio xuthus and its antimicrobial activity was suggested. In this study, the antifungal mechanism of papiliocin against Candida albicans was investigated. Confocal laser scanning microscopy (CLSM) and 1,6-diphenyl-1,3,5-hexatriene (DPH) fluorescence analysis indicated that papiliocin disturbed the fungal plasma membrane. Moreover, the assessment of the release of FITC-dextran (FD) from liposomes further demonstrated that the antifungal mechanism of papiliocin could have originated from the pore-forming action and that the radius of the pores was presumed to be anywhere from 2.3 to 3.3 nm.

Actinometry에 의한 CF4플라즈마에서의 F라디칼의 공간분포

  • 이우현;정재철;김동현;김혁;황기웅
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.217-217
    • /
    • 2011
  • 플라즈마를 이용하는 식각 및 증착등의 반도체공정에 있어서 최근에는 기판의 크기가 점차 증가하는 추세에 있다. 이러한 대면적 플라즈마 발생장치 내에서 플라즈마 밀도와 라디칼 농도의 공간적인 특성을 이해하는 것에 대한 중요성이 더해지고 있다. 이를 위해 Langmuir probe와 같은 전기적 접근법에 의한 진단방법이나 광학적 접근법에 의한 진단방법에 대한 연구가 이루어 졌다. 전기적 접근법에 의한 플라즈마의 진단방법은 원리가 간단하고 정확도가 높다는 장점이 있지만 진단 장치에 의한 플라즈마의 간섭이 크고 식각가스의 경우 진단이 어렵다는 단점이 있다. 그에 비해 광학적 진단방법은 플라즈마에 간섭이 많지 않은 방법으로 알려져 있고 레이저 형광법(LIF), 원적외선 레이저 흡수 분광법(IR laser Absorption Spectroscopy), 광량측정법(Actinometry)등이 있다. 이 중 레이저 형광법, 원적외선 레이저 흡수 분광법의 경우, 진단장치가 매우 복잡하고 가격이 비싸다는 단점을 가지고 있다. 반면 광량측정법의 경우 다른 광학적 접근법에 의한 진단방법에 비해 원리와 실험장치가 간단하고 공간적인 라디칼 분포의 진단이 쉽다는 점에서 장점을 가지고 있다. Actinometry는 Ar과 같은 불활성 기체를 작은 비율을 넣어서 여기 된 불활성 기체의 파장세기와 여기 된 측정 라디칼의 파장세기의 비교를 통해 상대밀도를 측정하는 방법이다. 이 측정 방법에 Abel's inversion equation을 적용함으로 해서 대면적 M-ICP(Magnetized - Induced Coupled Plasma)에서 식각가스인 $CF_4$플라즈마에서 F 라디칼 농도의 공간적인 분포를 측정하고 분석하였다. 또한 플라즈마의 압력, 소스 전력 값과 기판 전력 값등의 조건의 변화에 따라 F 라디칼 농도의 분포가 어떻게 달라지는지에 대해 측정 분석하여 다루었다.

  • PDF

Phase Transition Characteristics in $Ge_xSb_{100-x}$ Film for Optical Storage Media

  • Park Tae-jin;Kang Myung-jin;Choi Se-young
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.124-127
    • /
    • 2005
  • Rewritable optical memory devices such as an CD-RW and DVD+RW are data storage media, which take advantage of the different optical properties in the amorphous and crystalline states of phase change materials. The switching property, structural transformation, transformation kinetics and chemical bindings of $Ge_xSb_{100-x}$($6{\le}x{\le}$34) were studied to investigate the feasibility of applying $Ge_xSb_{100-x}$ alloys in optical memory. The $Ge_xSb_{100-x}$ thin film was deposited by RF magnetron co-sputtering system and phase change characteristics were investigated by X-ray diffraction (XRD), static tester, inductively coupled plasma atomic emission spectrometer (ICP-AES) and atomic force microscopy (AEM). Optimum fiim composition of $Ge_xSb_{100-x}$ was studied and its minimum time fur laser induced crystallization and optical contrast fur phase transition was performed. These results might be correlated with the binding energies between Ge and Sb, and indicate that $Ge_xSb_{100-x}$ have an potential far optical memory applications.

  • PDF

Flow Characteristics of Neutrally Buoyant Particles in 2-Dimensional Poiseuille Flow through Circular Capillaries

  • Kim, Young-Won;Jin, Song-Wan;Yoo, Jung-Yul
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.7-10
    • /
    • 2006
  • An experimental study has been conducted to quantitatively characterize the motion of neutrally buoyant particles in 2-dimensional Poiseuille flow through the micron-sized circular capillaries in the range of Re (Reynolds number) $\approx0.1\sim100$. $A{\mu}-PTV$ (Particle Tracking Velocimetry) system is adopted, which consists of a double-headed Nd:YAG laser, an epi-fluorescence microscope and a cooled CCD camera. Since high shear rate can be induced due to the scale effect even at low Re, it is shown that in micro scale neutrally buoyant particles in Poiseuille flow drift away from the wall and away from the center of the capillary. Consequently, particles accumulate at the equilibrium position of $0.52\sim0.64R$ with R being the radius of the capillary, which is analogous to that of tube flow in macro scale. There is a plateau in equilibrium position at small Re, while equilibrium position starts increasing at $Re\approx30$. The outermost edge of particle cluster is closer to the center of the capillary than that in previous studies due to low Re effect. The present study quantitatively presents characteristics of particle motion in circular capillaries. Furthermore, it is expected to give optimum factors for designing microfluidic systems that are to be used fur plasma separation from the blood.

  • PDF

레이저유도붕괴분광법을 활용한 토양의 정량분석 (Quantitative Elemental Analysis in Soils by using Laser Induced Breakdown Spectroscopy(LIBS))

  • 장용선;이계준;이정태;황선웅;진용익;박찬원;문용희
    • 한국토양비료학회지
    • /
    • 제42권5호
    • /
    • pp.399-407
    • /
    • 2009
  • 레이저 유도붕괴 분광법(LIBS)은 물질상태(고체, 액체, 기체)에 상관없이 신체 접촉시 오염 우려 및 미량 시료도 전처리 없이 동시에 많은 종류의 원소 분석으로 분석과정이 단순하고 신속하게 분석이 가능하며, 소형화된 레이저의 개발로 시료의 직접적인 채취가 어려운 조건의 현장분석에도 적합하다. 농산물 안정성 평가나 친환경 농업 및 정밀농업을 위한 조사 등에 활용될 수 있는 비파괴 실시간 정량분석기술로서 LIBS 분석법의 토양분석 가능성을 평가하고자 표준광물, 미국의 표준기술연구소의 표준토양, 미국 테네시주 초지 및 밭토양을 대상으로 토양 구성성분의 정성 정량적 분석에 필요한 측정조건을 조사하고 이를 토대로 LIBS에 의한 농도값과 기존의 화학분석법을 통해 측정한 결과를 비교하였다. LIBS 측정은 펄스형 Nd:YAG 레이저(Minilite II, Continuum, Santa Clara, CA)에서 나오는 1064 nm 에너지 파장의 광원을 시편의 플라즈마를 생성시키는데 사용하였고, 25 mJ/pulse 여기 에너지 빔을 펄스폭 35 ns, 펄스 반복 주기 10 Hz, 노출시간 10 s 동안 시료의 표면에 조사하였다. LIBS 분광은 0.03 nm의 해상력으로 200 nm에서 600 nm의 영역에서 50 m 이하로 분쇄하여 원형 펠렛 형태로 압축시킨 시료를 10 rpm의 속도로 회전시키면서 상온 상압의 실험실 조건에서 수행되었다. LIBS를 이용한 토양 중 주요한 원소의 적정 파장(nm)은 Al(I) 309.2 nm, Ca(I) 422.6 nm, Fe(I) 406.4 nm, Mg(I) 285.2 nm, Na(I) 589.2 nm, Si(I) 288.2 nm, Ti(I) 398.9 nm 이었다. LIBS의 피크강도가 물질 중 원소의 농도가 증가됨에 따라 각 원소의 특정 파장대에서 일정하게 증가되는 것으로 나타나고 있으나 표준물질의 LIBS의 신호비와 원소비를 통해 측정된 검량곡선의 상관계수($r^2$)는 0.863에서 0.977의 범위로 원소별로 상이할 뿐만 아니라 0.98에 미치지 못하였다. 또한, 토양 중 분석대상원소에 대하여 기존 ICP-AES에 의한 표준방법으로 분석된 시료의 측정값과 비교하여 상대적인 오차는 대략적으로 (-)40%에서 80%이상이며, 평균오차는 32.2%로 표준척도 20% 이상을 초과하였다. LIBS에 의한 토양분석은 토양의 조성과 입자의 크기에 따른 매질효과(matrix effect)로 표준물질의 검량곡선에서 결정계수가 낮고, 원소별 함량도 기준의 표준방법과 비교할 때 오차가 컸다. 따라서 LIBS에 의한 토양분석은 정성적인 분석 수준의 정밀도를 보였으며, 토양 매질의 영향을 최소화하기 위하여 기존의 분쇄 펠렛형 시료조제 및 회전측정 이외의 다양한 토양매질의 표준물질(standard reference material)의 확보, 새로운 전처리 방법 및 측정상 방법개선 등 신뢰성 있는 정량 분석을 위한 노력이 필요할 것으로 사료된다.

레이저 유도 형광법(Laser Induced Fluorescence)을 이용한 플라즈마 방전 표시기(Plasma Display Panel)내의 전계 측정에 관한 연구

  • 김정훈;이준학;최영욱;양진호;황기웅
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.232-232
    • /
    • 1999
  • 교류형 플라즈마 방전 표시기(AC Plasma Display Panel, AC PDP)에 사용되는 플라즈마는 그 부피가 너무 작아서 플라즈마에 변화를 일으키지 않고 그 물성을 관측하기란 쉬운일이 아니다. 그래서 주로 PDP 내의 물성을 관측하는 데 시뮬레이션에 의존하게 된다. 그 물성중에 PDP내의 전계 분포에 대한 정보는 방전의 형성 및 소멸에 대한 많은 단서를 제공하고 있다. 특히 AC PDP의 경우, 유전체에 형성되는 벽적하(wall charge)가 방전의 형성 및 PDP 구동에 중요한 역할을 하는데, 이는 PDP 내의 전계 분포를 살펴봄으로써 대략 예측할 수 있다. 본 연구에서는 시뮬레이션에 의존하지 않고, 직접 레이저 유도 형광법을 이용하여 AC PDP 내의 전계를 측정하였다. 방전 가스인 헬륨(He)의 에너지 준위는 전계의 크기에 따라 에너지 준위가 변화하여, Rydberg(n$\geq$8) 준위가 여러 개의 준위로 나누어지는 현상이 일어나는데, 이를 Stack 효과라고 한다. 따라서 전계의 세기가 커짐에 따라서 각 준위와 준위 사이 값(splitting)이 커지는데, 이를 이용하면 전계를 측정할 수 있다. 즉, 헬륨 원자를 여기시키는 레이저 파장을 변화시키면서 관측되는 레이저 유도 형광 신호를 관측하면, 준위의 splitting을 관측할 수 있다. 본 연구에서는 PDP 내의 전계의 시간적 변화를 관측하였다. 50%, 40kHz의 구형파를 PDP의 두 전극에 가하였을 때, 플라즈마가 켜진 상태뿐만 아니라 플라즈마가 꺼진 후에도 전계에 의한 Splitting 신호가 관측이 되었는데, 전계로 환산하였을 때, 그 값은 대략 수 kV/cm의 값을 갖았는데, 이는 wall charge에 의한 값으로 사료된다.결과로 생각되어진다.플라즈마의 강도값을 입력하여 플라즈마의 radiation을 검출하고, 스퍼터링 공정중 실질적인 in-situ 정보로 이용하였다. PEM을 통하여 In/Sn의 플라즈마 강도변화를 조사하였다. 초기 In/Sn의 플라즈마 강도(intensity)는 강도를 100하여, 산소를 주입한 결과, plasma intensity가 35 줄어들었고, 이때 우수한 ITO 박막을 얻을 수 있었다. Pulsed DC power를 사용하여 아크 현상을 방지하였다. PET 상에 coating 된 ITO 박막의 표면저항과 광투과도는 4-point prove와 spectrophotometer를 이용하여 분석하였고, AES로 박막의 두께에 따른 성분비를 확인하였다. ITO 박막의 광투과도는 산소의 유량과 sputter 된 In/Sn ion의 plasma emission peak에 따라 72%-92%까지 변화하였으며, 저항은 37$\Omega$/$\square$ 이상을 나타내었다. 박막의 Sn/In atomic ratio는 0.12, O/In의 비율은 In2O3의 화학양론적 비율인 1.5보다 작은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인 모양을 가지는 성장의 경우도 cluster 밀도, cluster 모양, cluster의 양 축 방향 길이 비, 양 축 방향의 평균 팔 넓이로부터 각 축 방향의 분산 장벽을 얻어낼 수 있을 것으로 보인다. 기대할 수 있는 여러

  • PDF

레이저 유도 충격파를 이용한 첨단 약물전달시스템 개발 (New Drug Delivery System Based on a Laser-Induced Shockwave)

  • 한태희;이현희;;여재익
    • 대한기계학회논문집B
    • /
    • 제34권1호
    • /
    • pp.67-71
    • /
    • 2010
  • 1 GW/$cm^2$ 이상의 고강도의 레이저 빔을 얇은 금속 호일의 한 점에 집중시키면, 레이저 삭마현상에 의해 발생된 충격파가 금속 호일 안으로 전파하게 된다. 이 충격파는 금속 호일의 반대 면에서 팽창파로 반사되고, 그 과정에서 금속 호일에 급격한 변형이 일어난다. 이 때, 금속 호일의 반대 면에 미세한 마이크로 단위 크기의 입자들을 코팅하면, 금속의 순간적인 변형으로 인해 입자들이 큰 운동량을 얻으며 가속되어 빠른 속도로 튕겨져 나가게 되는데 이것이 바이오리스틱 약물 전달의 원리이다. 이번 연구에서는 바이오리스틱 시스템의 제어성, 안정성, 효율을 향상시키고자 컨파인 조건을 변화시키며, 인체의 연한 조직을 모사하는 3% 젤라틴 용액으로의 침투 모습을 파악하였다. 사용한 컨파인 매질은 BK7 유리, 물, 그리고 초음파젤(RHAPAPHRM Co. Ltd)이다. 실험결과, 컨파인 매질과 그 두께를 조절함으로써 마이크로 입자들의 침투 양상을 제어할 수 있음을 확인하였다.